BEGA 84983 Gobo Floodlight Instruction Manual
- June 15, 2024
- BEGA
Table of Contents
BEGA 84983 Gobo Floodlight
Instructions for use
Application
- Floodlight for the projection of Gobo motifs.
- For installation on BEGA profile poles with profile groove.
- Suitable for Gobo motifs in accordance with size E in the Rosco table
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Clear safety glass Silicone gasket
- Projector lens with adjustable glass lenses.
- Suitable for Gobos with an outer diameter of 37.5mm, a max. image diameter of 28mm and a material thickness of max. 1mm
- Rotation range of floodlight 350°
- Swivel range -20°/+100°
- Connecting cable X05BQ-F 5G1mm²
- Cable length 1m BEGA Ultimate Driver®
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-276 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
BEGA Thermal Control
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK06
- Protection against mechanical impacts < 1 joule
- c – Conformity mark
- Wind catching area: 0.04 m²
- Weight: 2.8 kg
- This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Installation
Loosen the hexagon socket screws (wrench size 5mm) at the pole head and lift out the connection box. Insert the floodlight into the profile groove on the profile pole and fix it in the desired position using both hexagon socket screws (wrench size 4 mm) (see sketch A). Route the connecting cable for the floodlight into the pole through the closest slotted hole in the profile groove. The electrical connection is made in the connection box in the pole head. Guide the floodlight connecting cable through the cable gland into the connection box. Tighten the screw cable gland. Make the earth conductor connection and the electrical connection.
Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow (1), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire. The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output. Place the connection box on the profile pole and secure it in place. Make sure that gasket is positioned correctly. Tighten the screws uniformly in crosswise fashion.
Adjust floodlight
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B, C).
Torque
- Hexagon socket screw = 7 Nm
- Hexagon nut = 35 Nm
- Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).
Inserting a Gobo
Open the floodlight: Turn the lens cover anticlockwise and lift off. To insert
a gobo, adjust the knurled screw R4 of the gobo holder so that it is in line
with the knurled screw R3 below it. Loosen the three knurled screws R3, turn
the lens cylinder clockwise to the stop and lift it off. Remove the retaining
ring on the Gobo receptacle and insert the Gobo. Make sure to insert the motif
inverted and upside down. Align the Gobo according to the subsequent
floodlight position.
Exact alignment is possible in the mounted position via knurled screw R4 within a range of ± 22.5°. Insert the retaining ring (note the locking lugs) and replace the lens cylinder, turn it clockwise as far as it will go and tighten the three knurled screws R3 hand-tight. Adjusting the Gobo motif size and focus: Switch on the floodlight. The size and focus of the Gobo motif is adjusted by moving the lens holder. Loosen the two knurled screws R1 and R2 and adjust the lens distance until the desired size is reached.
A larger lens distance will make the motif smaller, a smaller distance will make it larger. Tighten the knurled screw R1. Use the second lens to adjust optimal focus and then tighten the knurled screws R2. The shields provided (with 20 and 30mm apertures) are used to optimise the degree of illuminance and sharpness. Place the shields on the lens cylinder with the side lugs pointing outward to choose the right one.
Finally, insert the side lugs of the shield into the lens cylinder. The desiccant pouch provided in the delivery must be placed inside the luminaire to ensure max. service life of the electric components. Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Position the lens cover on the floodlight housing so that the notches in the
floodlight housing and the lens cover are congruent. Screw on the lens cover
clockwise until the stop. Screw in the locking pin (hexagon socket
wrench SW 2.5) on the back of the floodlight housing.
Gobo motifs
You can find a large selection of Gobo motifs or have them customised to your
specifications in the corresponding Rosco standard sizes at
www.castinfo.de.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e.g. transients, etc. we recommend separate
overvoltage protection components. You can find them on our website at
www.bega.com.
Lamp
- Module connected wattage 21.6 W
- Luminaire connected wattage 24 W
- Rated temperature ta=25 °C
- Ambient temperature ta max=45 °C
84 983K3
- Module designation LED-1145/930
- Colour temperature 3000 K
- Colour rendering index CRI >90
- Module luminous flux 2770 lm
- Luminaire luminous flux * 410 lm
- Luminaire luminous efficiency * 17,1 lm/W
84 983K4
- Module designation LED-1145/940
- Colour temperature 4000 K
- Colour rendering index CRI >90
- Module luminous flux 2910 lm
- Luminaire luminous flux * 430 lm
- Luminaire luminous efficiency * 17,9 lm/W
preliminary data
- Lighting technology
- Beam angle 10°-14°
- Technique d’éclairage
- Angles de rayonnement 10°-14°
- Reinigung · Pflege
- Leuchte regelmäßig mit lösungsmittelfreien
- Reinigungsmitteln von Schmutz und
- Ablagerungen säubern.
- Dafür keinen Hochdruckreiniger verwenden.
- Cleaning · Maintenance
- Clean luminaire regularly with solvent-free
- cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGAreplacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the system. Loosen the locking pin
(hexagon socket wrench SW2.5) on the back of the floodlight housing. Turn the
lens cover clockwise and lift it off. Undo the 4 mounting screws of the lens
unit (Torx drive T20) and remove the complete lens unit. Replace LED module.
Please follow the installation instructions for the LED module.
Replace and secure the lens unit. Switch on the floodlight, check the Gobo motif size and focus, and adjust as needed. Position the lens cover on the floodlight housing so that the notches in the floodlight housing and the lens cover are congruent. Srew on the lens cover clockwise until the stop. Screw in the locking pin.
Accessories
Profile poles made of lacquered aluminium
- 84 700 square H 4000 mm
- 84 701 square H 6000 mm
- 84 702 round H 4000 mm
- 84 703 round H 6000 mm
Profile poles with glued laminated wood in accordance with DIN EN 14080
- 84 696 square H 4000 mm
- 84 697 square H 6000 mm
- 84 698 round H 4000 mm
- 84 703 round H 6000 mm
For the accessories a separate instructions for use can be provided upon request.
Spares
- Shield ø 20 mm 16 006 501
- Shield ø 30 mm 16 006 502
- Lens cover graphite 25 000 165
- Lens cover silver 25 000 166
- LED power supply unit DEV-0412/600
- LED module 3000 K LED-1145/930
- LED module 4000 K LED-1145/940
- Gasket housing 83 000 521
- Gasket Lens cover 83 001 952
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com