CORBETT 434-14-VGL Coralie One Light Pendant Instruction Manual

June 13, 2024
CORBETT

CORBETT 434-14-VGL Coralie One Light Pendant

CORBETT-434-14-VGL-Coralie-One-Light-Pendant-product

Product Information

The product is a lighting fixture manufactured by the Hudson Valley Lighting Group. It is part of the Corbett Coralie collection. The fixture is designed for indoor installation and comes with various parts and hardware for assembly.

Parts Included

  • A – Crossbar
  • B – Mounting Screws
  • C – Nipple
  • D – Tooth Washer
  • E – Hex Nut
  • F – Collar Loop
  • G – Ground Screw
  • H – Collar Loop
  • I – Screw Collar
  • J – Canopy
  • K – Chain
  • L – Fixture Assembly
  • M – Metal Decorations
  • N – Capiz Decorations

Replacement Parts

  • Hardware Kit – Part Number: HDW
  • Canopy – Part Number: CPY
  • Chain – Part Number: CHN
  • Metal Decorations – Part Number: DEC-M
  • Capiz Decorations – Part Number: DEC-C

Important Safety Instructions

  • Never connect the ground wire to the hot wire. Failure to follow this could result in serious injury or death.
  • Make sure there are no exposed wires or strands that could cause a dangerous short circuit.
  • Never reverse hot and neutral wires. Failure to follow this could result in serious injury or death.
  • The fixture is rated for a 60-watt Type B lamp. Do not exceed the recommended wattage.

Product Usage Instructions

  1. Fixture Installation:
  2. Attach the crossbar (A) using the mounting screws (B).
  3. Secure the screw collar (I) and collar loop (H) onto the nipple (C).
  4. Attach the nipple (C) to the crossbar (A) using a hex nut (E) and tooth washer (D).
  5. Connect the collar loop (H) to the canopy (J) using a nipple (C).
  6. Attach the fixture assembly (L) to the collar loop (H) using a chain (K).
  7. Secure the screw collar (I), canopy (J), collar loop (H), nipple (C), and crossbar (A) together.
  8. Grounding:
    • Use the ground screw (G) to properly ground the crossbar (A).
    • Ensure the ground wire is not connected to the hot wire.
  9. Electrical Wiring:- SPT N (SPT wire with no writings): Use wire nuts (G) to connect wires. Make sure there are no exposed wires or strands that could cause a short circuit.

– SPT (SPT with writings): Never reverse hot and neutral wires.

  1. Fixture Assembly:
    • Attach the canopy (J) to the screw collar (I) and collar loop (H).
    • Insert the bulb (O) into the socket of the fixture assembly (L). Use a 60-watt Type B lamp or lower.
    • Decorate the fixture assembly (L) with optional Capiz decorations (N) or metal decorations (M).

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

Installation Instructions

FIXTURE INSTALLATIONCORBETT-434-14-VGL-Coralie-One-Light-Pendant-
fig-1

  1. Attach the CROSSBAR (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.

  2. Remove the SCREW COLLAR (I) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with TOOTH WASHER (D). Then thread the NIPPLE (C) onto the CROSSBAR (A). Adjust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extends 1/4″ beyond the CANOPY (J). Secure using HEX NUT (E).

  3. Open the end link the of the CHAIN (K) and attach to the FIXTURE ASSEMBLY (L) at the desired height. Slide the SCREW COLLAR (I) and the CANOPY (J) onto the CHAIN (K). Open the link on other end of the CHAIN (K) then attach unto the COLLAR LOOP (H). Feed the wires through the CHAIN (K) , SCREW COLLAR (I), CANOPY (J), COLLAR LOOP (H), NIPPLE (C), and CROSSBAR (A).

  4. Cut off excess wires, and strip the insulation off the end of the leads.

  5. Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the CROSSBAR (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE!FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!

  6. Connect the fixture’s SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G).
    Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!

  7. Connect the fixture’s SPT hot (SPT WITH WRITNGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!

  8. Push the wires back into the junction box. Lift up the CANOPY (J) up to the ceiling, and screw the SCREW COLLAR (I) onto the COLLAR LOOP (H).

  9. Screw the BULB (O) up into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR 60 WATT TYPE B LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!

  10. Attach the CAPIZ DECORATIONS (N) onto the FIXTURE ASSEMBLY (L) by inserting its clips in the holes.

  11. Attach the METAL DECORATIONS (M) onto the FIXTURE ASSEMBLY (L).

  12. Restore power to the OUTLET at the breaker or fuse box.

PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D,E,F,G,H,I HARDWARE KIT HDW-434-14
J CANOPY CPY-434-14
K CHAIN CHN-434-14
M METAL DECORATIONS DEC-434-14M
N CAPIZ DECORATIONS DEC-434-14C

www.hvlgroup.com

Documents / Resources

| CORBETT 434-14-VGL Coralie One Light Pendant [pdf] Instruction Manual
434-14-VGL Coralie One Light Pendant, 434-14-VGL, Coralie One Light Pendant, One Light Pendant, Light Pendant, Pendant
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CORBETT User Manuals

Related Manuals