MEAN WELL HEP-150 Switching Power Supply for Harsh Environment User Guide
- June 4, 2024
- MEAN WELL
Table of Contents
MEAN WELL HEP-150 Switching Power Supply for Harsh Environment
Features
- Universal AC input/ Full range (up to 305VAC)
- Built-in active PFC function
- High efficiency up to 94%
- Fanless design, cooling by free air convection
- -55+70 C wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Protections: Short circuit/Overload/ Over voltage /Over temperature
- Operating altitude up to 5000 meters (Note.9)
- 6 years warranty
Applications
Outdoor telecommunication equipment
Outdoor electronic signage and billboard
Petroleum plant or mine shaft facility
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HEP-150 is a 150W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 94%, enabling HEP-150 perfectly work between -55C and +70C under free air convection.
Model Encoding
Specification
MODEL| HEP-150-12| HEP-150-15| HEP-150-24|
HEP-150-36| HEP-150-48| HEP-150-54
---|---|---|---|---|---|---
DC VOLTAGE| 12V| 15V| 24V| 36V| 48V| 54V|
RATED CURRENT| 12.5A| 10A| 6.3A| 4.2A| 3.2A| 2.8A|
RATED POWER| 150W| 150W| 151.2W| 151.2W| 153.6W| 151.2W|
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p|
150mVp-p| 200mVp-p| 200mVp-p| 200mVp-p|
VOLTAGE ADJ. RANGE Note.5| 10.8 ~ 13.5V| 13.5 ~ 17V| 22 ~ 27V|
33 ~ 40V| 43 ~ 53V| 49 ~ 58V|
CURRENT ADJ. RANGE| Can be adjusted by internal potentiometer for A type
only|
7.5 ~ 12.5A| 6 ~ 10A| 3.8 ~ 6.3A| 2.5 ~ 4.2A| 1.92 ~ 3.2A| 1.68 ~ 2.8A|
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%|
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
LOAD REGULATION| ±2.0%| ±1.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%|
SETUP, RISE TIME Note.7| 1000ms,50ms/115VAC 500ms,50ms/230VAC at full
load|
HOLD UP TIME (Typ.)| 16ms at full load 230VAC /115VAC|
VOLTAGE RANGE Note.4| 85~264VAC (277VAC operational)
120~370VDC(390VDC operational)|
FREQUENCY RANGE| 47 ~ 63Hz|
POWER FACTOR (Typ.)| PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at
full load|
EFFICIENCY (Typ.)| 91.5%| 92%| 93%| 93.5%| 94%| 94%|
AC CURRENT (Typ.)| 1.7A / 115VAC 0.75A / 230VAC
0.7A / 277VAC|
INRUSH CURRENT(Typ.)| COLD START 65A at 230VAC|
LEAKAGE CURRENT| <0.75mA / 277VAC|
OVERLOAD| 105 ~ 125%|
Protection type : Constant current limiting, recovers automatically after
fault condition is removed|
SHORT CIRCUIT| Constant current limiting, recovers automatically after
fault condition is removed|
OVER VOLTAGE
| 14 ~ 17V| 18 ~ 21V| 28 ~ 34V| 41 ~ 46V| 54 ~ 63V| 59 ~ 65V|
Protection type : Shut down o/p voltage with auto-recovery or re-power on to
recovery|
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down|
WORKING TEMP.| -55 ~ +70℃ (Refer to “Derating Curve”)|
WORKING HUMIDITY| 20 ~ 95% RH non-condensing|
STORAGE TEMP., HUMIDITY| -60 ~ +80℃, 10 ~ 95% RH non-condensing|
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)|
VIBRATION| 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along
X, Y, Z axes|
SAFETY STANDARDS Note.6,9| UL62368-1, IEC62368-1,IP65 (or IP68 for
HEP-150 Blank type), EAC TP TC 004 approved ;
Design refer to BS EN/EN62368-1
|
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH|
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2,-3, EAC TP TC 020|
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level (surge 6KV),
EAC TP TC 020
|
MTBF| 1967.4K hrs min. Telcordia SR-332 (Bellcore) ; 164.2Khrs
min. MIL-HDBK-217F (25℃)|
DIMENSION| 2286838.8mm (LWH)|
PACKING| 1.15Kg; 12pcs/14.8Kg/0.8CUFT|
Note:
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltages. Please check the static characteristics for more details.
- A type only.
- Safety and EMC design refer to BS ENEN60598-1, CNS15233, GB7000.1, FCC part18.
- Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.
- The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- The ambient temperature derating of 3.5 C /1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft).
X Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derative Curve
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)