HALO RL4069NLWHDMR RL-DM Night Light Downlight User Guide
- June 14, 2024
- HALO
Table of Contents
RL-DM Night Light Downlight
RL4069NLWHDMR RL-DM Night Light Downlight
Dimming Guide and Step-down Transformer Application Note
The RL-DM Night Light LED Series provides continuous dimming with reverse or
forward phase cut dimmers.
RL4DM Night Light | RL6DM Night Light |
---|---|
RL4069NLWHDMR | RL6069NLWHDMR |
Phase Control Dimming
RL4-DM Night Light
Reference
Dimmer Make| Dimmer Series| Dimmer Model #|
Minimum Luminaires (per circuit)| Maximum Recommended
Luminaires (per circuit)| Min Dimming percentage (%)| Max
Dimming percentage (%)| Low End Start Time
---|---|---|---|---|---|---|---
Leviton| Decora| 6672| 1| 56| 4%| 98%| <1s
Leviton| SureSlide| 6674| 1| 14| 7%| 98%| <1s
Leviton| SureSlide| DSL06-ILZ| 1| 56| 7%| 98%| <1s
Leviton| Illumatech| IPL06-ILZ| 1| 14| 6%| 97%| <1s
Leviton| Decora| TSL06-1LW| 1| 47| 5%| 100%| <1s
Leviton| SureSlide| RDL06-1OZ| 1| 56| 4%| 100%| <1s
Lutron| Toggler| TG-600P| 1| 56| 0%| 96%| >1s 1
Eaton| RF Smart| RF9540-N| 1| 28| 4%| 100%| <1s
Lutron| Toggler| TGCL-153P| 1| 14| 2%| 96%| <1s
Lutron| Lumea| LG600P| 1| 56| 0%| 97%| >1s 1
EWD| Universal| TUL06P-C2| 1| 28| 3%| 98%| <1s
EWD| Universal| SUL06P| 1| 28| 2%| 98%| <1s
Lutron| Skylark| SCL-153P-WH| 1| 14| 2%| 95%| <1s
Lutron| Diva| DV603P| 1| 56| 0%| 96%| >1s 1
Lutron| Diva| DVCL-153P| 1| 14| 2%| 95%| <1s
Lutron| Maestro| MACL-153-M| 1| 14| 6%| 89%| <1s
Leviton| Vizia| VPE06| 1| 56| 6%| 100%| <1s
Leviton| Legrand| H703PTU| 1| 28| 4%| 100%| <1s
Leviton| Vizia| VZE04| 1| 37| 7%| 100%| <1s
Leviton| Acenti| ATX10| 1| 94| 5%| 100%| <1s
Lutron| Maestro| MAELV600| 1| 56| 8%| 99%| <1s
Lutron| Faedra| FAELV500| 1| 47| 0%| 99%| >1s 1
Lutron| Diva| DVELV303P| 1| 28| 4%| 99%| <1s
Lutron| Skylark| SELV300P| 1| 28| 4%| 99%| <1s
EWD| Smart| AAL06| 1| 28| 8%| 98%| <1s
Lightolier| Sunrise| ZP260QEW| 1| 24| 4%| 97%| <1s
Eaton| Aspire| 9530AW| 1| 56| 0%| 99%| >1s 1
Eaton| Skye| SF8AP| 1| 90| 14%| 99%| <1s
Eaton| Devine| DE06P| 1| 56| 1%| 88%| <1s
Eaton| React| RI061| 1| 56| 0%| 100%| >1s 1
Eaton| Devine| TAL06P| 1| 28| 2%| 98%| <1s
Eaton| Toggle| DAL06P| 1| 28| 3%| 98%| <1s
Eaton| Skye| SAL06P| 1| 28| 3%| 98%| <1s
Eaton| Skye| SLC03P| 1| 28| 2%| 98%| <1s
Eaton| Devine| DLC03P| 1| 28| 1%| 98%| <1s
Eaton| Toggle| TI061| 1| 56| 0%| 82%| >1s 1
Lutron(PANEL)| LCP128 (TRIAC)| LP-RPM-4U-120| 1| 180| 0%| 99%| >1s 1
Lutron(PANEL)| LCP128 (ELV)| LP-RPM-4A-120| 1| 112| 0%| 98%| >1s 1
Ecospec(PANEL)| LDCM| LDCM-PL-120-277-010V-GR| 1| 42| 0%| 100%| >1s 1
Lutron| Ariadni| AY-600P| 1| 56| 0%| 97%| >1s 1
Lutron| Contour| CT-103P| 1| 94| 0%| 98%| >1s 1
Lutron| Contour| CT-600P| 1| 56| 0%| 98%| >1s 1
Lutron| Rotary| D-600P| 1| 56| 0%| 96%| >1s 1
Lutron| Diva| DV-600P| 1| 56| 0%| 97%| >1s 1
Lutron| Glyder| GL-600P| 1| 56| 0%| 97%| >1s 1
Lutron| Lumia| LG-600PH| 1| 56| 0%| 97%| >1s 1
Lutron| Maestro| MA-600| 1| 56| 9%| 99%| <1s
Lutron| Nova| N-600| 1| 56| 0%| 98%| >1s 1
Lutron| Skylark| S-600P| 1| 56| 0%| 96%| >1s 1
Lutron| Centurion| C-600P| 1| 56| 0%| 97%| >1s 1
Lutron| Ariadni| AYLV-600P| 1| 42| 0%| 96%| >1s 1
Lutron| Glyder| GLV-600| 1| 42| 0%| 97%| >1s 1
Lutron| Diva| DVLV-600P| 1| 42| 0%| 95%| >1s 1
Lutron| Lumina| LG-103P| 1| 94| 0%| 96%| >1s 1
Lutron| Skylark| SLV-600P| 1| 42| 0%| 96%| >1s 1
EWD| Universal| DUL06P-C7| 1| 28| 3%| 95%| <1s
Lutron| Nova| NTLV-600| 1| 28| 4%| 97%| <1s
Lutron| Nova| NT-600| 1| 42| 0%| 97%| >1s 1
RL6-DM Night Light
Reference
Dimmer Make| Dimmer Series| Dimmer Model #|
Minimum Luminaires (per circuit)| Maximum Recommended
Luminaires (per circuit)| Min Dimming percentage (%)| Max
Dimming percentage (%)| Low End Start Time
---|---|---|---|---|---|---|---
Leviton| Decora| 6672| 1| 41| 3%| 97%| <1s
Leviton| SureSlide| 6674| 1| 10| 6%| 97%| <1s
Leviton| SureSlide| DSL06-ILZ| 1| 41| 5%| 98%| <1s
Leviton| Illumatech| IPL06-ILZ| 1| 10| 5%| 97%| <1s
Leviton| Decora| TSL06-1LW| 1| 34| 5%| 99%| <1s
Leviton| SureSlide| RDL06-1OZ| 1| 41| 3%| 100%| <1s
Lutron| Toggler| TG-600P| 1| 41| 0%| 93%| >1s 1
Lutron| Nova T| NTFTU-6A| 1| 41| 18%| 100%| <1s
Eaton| RF Smart| RF9540-N| 1| 20| 4%| 99%| <1s
Lutron| Maestro| MAW600| 1| 41| 7%| 99%| <1s
Lutron| Toggler| TGCL-153P| 1| 10| 2%| 96%| <1s
Lutron| Lumea| LG600P| 1| 41| 0%| 97%| >1s 1
EWD| Universal| TUL06P-C2| 1| 20| 2%| 96%| <1s
EWD| Universal| SUL06P| 1| 20| 2%| 96%| <1s
Lutron| Skylark| SCL-153P-WH| 1| 10| 2%| 95%| <1s
Lutron| Diva| DV603P| 1| 41| 0%| 97%| >1s 1
Lutron| Diva| DVCL-153P| 1| 10| 2%| 95%| <1s
Lutron| Maestro| MACL-153-M| 1| 10| 6%| 88%| <1s
Leviton| Vizia| VPE06| 1| 41| 4%| 100%| <1s
Leviton| Legrand| H703PTU| 1| 20| 4%| 100%| <1s
Leviton| Vizia| VZE04| 1| 27| 6%| 100%| <1s
Leviton| Acenti| ATX10| 1| 69| 5%| 99%| <1s
Lutron| Maestro| MAELV600| 1| 41| 6%| 99%| <1s
Lutron| Diva| DVELV303P| 1| 20| 3%| 98%| <1s
Lutron| Skylark| SELV300P| 1| 20| 3%| 98%| <1s
EWD| Smart| AAL06| 1| 20| 6%| 98%| <1s
Lightolier| Sunrise| ZP260QEW| 1| 18| 4%| 97%| <1s
Eaton| Aspire| 9530AW| 1| 41| 0%| 100%| >1s 1
Eaton| Skye| SF8AP| 1| 66| 16%| 100%| <1s
Eaton| Devine| DE06P| 1| 41| 1%| 88%| >1s
Eaton| React| RI061| 1| 41| 0%| 100%| >1s 1
Eaton| Devine| TAL06P| 1| 20| 2%| 100%| <1s
Eaton| Toggle| DAL06P| 1| 20| 2%| 100%| <1s
Eaton| Skye| SAL06P| 1| 20| 2%| 99%| <1s
Eaton| Skye| SLC03P| 1| 20| 2%| 98%| <1s
Eaton| Devine| DLC03P| 1| 20| 1%| 99%| <1s
Eaton| Toggle| TI061| 1| 41| 0%| 81%| >1s 1
Lutron(PANEL)| LCP128 (TRIAC)| LP-RPM-4U-120| 1| 133| 0%| 100%| >1s 1
Lutron(PANEL)| LCP128 (ELV)| LP-RPM-4A-120| 1| 83| 0%| 99%| >1s 1
Ecospec(PANEL)| LDCM| LDCM-PL-120-277-010V-GR| 1| 31| 0%| 100%| >1s 1
Lutron| Ariadni| AY-600P| 1| 41| 0%| 97%| >1s 1
Lutron| Contour| CT-103P| 1| 69| 0%| 97%| >1s 1
Lutron| Contour| CT-600P| 1| 41| 0%| 96%| >1s 1
Lutron| Rotary| D-600P| 1| 41| 0%| 94%| >1s 1
Lutron| Diva| DV-600P| 1| 41| 0%| 96%| >1s 1
Lutron| Glyder| GL-600P| 1| 41| 0%| 96%| >1s 1
Lutron| Lumia| LG-600PH| 1| 41| 0%| 96%| >1s 1
Lutron| Maestro| MA-600| 1| 41| 7%| 95%| <1s
Lutron| Nova| N-600| 1| 41| 0%| 96%| >1s 1
Lutron| Skylark| S-600P| 1| 41| 0%| 95%| >1s 1
Lutron| Centurion| C-600P| 1| 41| 0%| 99%| >1s 1
Lutron| Ariadni| AYLV-600P| 1| 31| 0%| 98%| >1s 1
Lutron| Glyder| GLV-600| 1| 31| 0%| 99%| >1s 1
Lutron| Diva| DVLV-600P| 1| 31| 0%| 95%| >1s 1
Lutron| Lumina| LG-103P| 1| 69| 0%| 96%| >1s 1
Lutron| Skylark| SLV-600P| 1| 31| 0%| 96%| >1s 1
EWD| Universal| DUL06P-C7| 1| 20| 2%| 94%| <1s
Lutron| Nova| NTLV-600| 1| 20| 3%| 97%| <1s
Lutron| Nova| NT-600| 1| 31| 1%| 98%| <1s
Dimmer Notes:
- Start time is measured at the lowest dimmer setting.
- Some LED dimmers have a “rapid start” design used to provide a momentary power boost to LED and CFL lamps during start-up.
When a LED luminaire is on a dimmer with “rapid start” the boost may cause a momentary flash of the LED lighting. This “flash” is generated by the dimmer, and may be more noticeable when the dimmer is at a low setting. A solution is available with EATON dimmers which provide adjustment capability of the “rapid start”: Devine (DAL06P), Accell (AAL06P), and Trace (TAL06P). Refer to product specifications online at www.eaton.com for more details.
Dimming Guide Disclaimer:
- Leviton® is a registered trademark of Leviton Manufacturing Co. Inc.; Lutron® is a registered trademark of Lutron Electronics Co. Inc.; Lightolier® is a registered trademark of Philips Lighting; Hubbell® is a registered trademark of Hubbell Incorporated; Legrand® and Pass & Seymour® are registered trademarks of Legrand® ; Eaton® is a registered trademark of Eaton Corporation. These companies and their tradenames, trademarks or brands, where noted, are associated with their respective company and are not associated with Cooper Lighting Solutions.
- Testing conducted by Cooper Lighting Solutions is not a substitute for and does not imply certification by an independent laboratory or any other standards certification. Refer to the manufacturer specifications for more detailed information on product certifications and standards.
- This is a representative list of typical dimmers as tested by Cooper Lighting Solutions for performance with the designated LED luminaires only. Test data contained in this literature is based upon dimmers obtained in the marketplace. Information about these other manufacturers products is obtained from packaging and published information made available by the manufacturer and is deemed to be reliable, but has not been verified. Dimmer performance and perceived limitations of the dimmers are based on factors outside of Cooper Lighting Solutions’ control. The specifications of these dimming controls and their conditions of use may change without notice to Cooper Lighting Solutions or any other user. Cooper Lighting Solutions makes no specific recommendation on product selection and there are no warranties of performance or compatibility implied. Installer must ensure proper local and national electrical codes are followed; and that the dimmer application and condition of use is per dimmer manufacturer instructions and guidelines.
Application Note
– H277, H347 and H347200 step-down transformers are qualified to drive multiple Halo LED on a single circuit in Non-IC construction. Installation of these transformers with individual LED fixtures on circuits with multiple LED loads is not recommended. This is not recommended due to resulting multiple inductive currents pulled by each transformer; in this situation the majority of the power would then be reactive (VARS) and not real (WATTS). If H277, H347 or H347200 transformers should be used individually on each LED fixture in a single circuit, then that circuit should be sized for lowered power factor as well as increased apparent power on the circuit. H277, H347 and H347200 are UL/cUL listed for use with Halo recessed housings: H750T, H750TCP, H7T, H7TNB, H7RT.
Step Down Transformers
H277 = Steps 277 line voltage down to 120 volts. Attaches to knockout on first
fixture’s junction box in a circuit and is 300VA rated. H277 is a UL
recognized Component listed under the luminaire UL/cUL listing for Halo Non-IC
housings.
H347 and H347200 = Steps 347 line voltage down to 120 volts. Attaches to
knockout on first fixture’s junction box in a circuit. H347 is 75VA and
H347200 is 200VA rated. H347 is a CSA/UL Listed Component for use under the
luminaire UL/cUL listing with Halo Non-IC housings.
Transformer Load – H277 (300VA)
- H277 Transformer at full loading consumes a maximum of 16W of power.
- When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumed by the transformer when the dimmer or switch is in “OFF” mode at 6.5W and in “ON” mode at 16W maximum under full loading.
- When a dimmer or switch is on the primary (277V) side ahead of the transformer, power is consumed only in “ON” mode to a maximum of 16W under full loading. (Use of a dimmer ahead of the transformer is not recommended)
Transformer Load – H347 (75VA)
- H347 Transformer at full loading consumes a maximum of 15W of power.
- When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumed by the transformer when the dimmer or switch is in “OFF” mode at 2.5W and in “ON” mode at 15W maximum under full loading.
- When a switch is on the primary (347V) side ahead of the transformer, power is consumed only in “ON” mode to a maximum of 15W under full loading. (Use of a dimmer ahead of the transformer is not recommended)
Transformer Load – H347200 (200VA)
- H347200 Transformer at full loading on 120V side consumes a maximum of 28W of power.
- When a dimmer or switch is on the secondary (120V) side of the transformer, power is consumed by the transformer when the dimmer or switch is in “OFF” mode at 9.2W and in “ON” mode at 28W maximum under full loading.
- When a switch is on the primary (347V) side ahead of the transformer, power is consumed only in “ON” mode to a maximum of 28W under full loading.
When a switch is on the primary (277V) side ahead of the transformer, power is consumed only in “ON” mode to a maximum of 12W under full loading.
(Use of a dimmer ahead of the transformer is not recommended)
HLB Retrofit LED Downlight Series
(HLB Maximum Units on Step Down Transformer Powered Circuits)
Max # of Fixtures
Transformer | VA Rating | 600 Series | 900 Series |
---|---|---|---|
H277 | 300 | 24 | 16 |
H347 | 75 | 6 | 4 |
H347200 | 200 | 16 | 10 |
Transformer with Dimmer/Switch on 120V Secondary Transformer with Switch on 277V Primary
Transformer with Switch on 347V Primary *Use of a dimmer ahead of the transformer is not recommended
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2022 Cooper Lighting Solutions
All Rights Reserved.