SDC 528 Montoring Switch Kit Instruction Manual

June 4, 2024
SDC

INSTALLATION INSTRUCTIONS
528
MONTORING SWITCH KIT
SARGENT 20, 60 SERIES

528 Montoring Switch Kit

ORG N/C
YEL N/O
WHT COM

10A @ 125VAC RESISTIVE

Applications

Remote Latch Status Monitoring:
Retracting the latch by depressing the push pad provides an output signal for local or remote visual and audible annunciation indicating forced entry or unauthorized egress.
Access Control REX: When connected to the Request-To-Exit input of a keypad, card, or biometric Access Controller, depressing the push pad and retracting the latch actuates the Latch Status contact, shunting the control access control alarm to permit authorized egress and/or releases the magnetic door lock for uninhibited egress.
Magnetic Lock Release: Where Access Controller with REX input is unavailable, the N/C contact of the switch is wired in series between the power supply and fail-safe magnetic lock. Depressing the exit device push pad retracts the latch, causing the contact to open, thereby releasing the magnetic lock for uninhibited egress.
Mantrap Logic: Provides N/O and N/C contacts required for 2 or more communicating doors for Interlock and Mantrap applications.
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

P:\INST INSTRUCTIONS\EGRESS CONTROLS\INST-528 REV D 07-21

SECURITY DOOR CONTROLSWWW.SDCSECURITY.COM
[t] 800.413.8783 • 805.494.0622 • E-mail: service@sdcsecurity.com • 801 Avenida Acaso, Camarillo, CA 93012 • PO Box 3670, Camarillo, CA 93011