MINOSTON MR40Z S2 Remote Control Switch User Manual

June 9, 2024
Minoston

MINOSTON MR40Z S2 Remote Control Switch

**S2 Remote Control Switch

MINOSTON-MR40Z-S2-Remote-Control-Switch-fig-
\(1\)**

Specification

  • Battery: CR2032*2
  • Frequency: 908.42MHz
  • Temperature Range: 32°F~104°F
  • Indoor use in dry location
  1. Please read the online guides at support Minosto.com/Z-wave remote carefully
  2. Do not use it in locations with direct water contact.
  3. Contains small parts that keep away from children.

Power the device

  1. Use by hand open the remote cap and push in to separate the 2 halves
  2. Remove the battery tabs
  3. Your Z-wave removed Immediately should flash an LED to indicate it is powered.

S2 Remote Control Switch features

  1. Power by battery, no need wires needed. Note the ± direction of the battery
  2. Control other Z-wave devices and enable scenes with a click of a button
  3. The device with S2 and SmartStart support

Please contact us if you have any questions:
ask@minoston.com
www.minoston.com

Z-wave Control

Adding a Device To your hub and Z-Wave Network for a QR code

Choose your hub into and scan the QR code with your phone’s camera and add to Smartstar
Note : DSK Code can be foucd on packaging. Do not remove or damage them MINOSTON-MR40Z-S2-Remote-Control-Switch-fig- \(4\)

Inclusion/Exclusion Function

To add the device

  1. Follow the instructions for your Z-Wave certified controller to add a device from the Z-Wave network.
  2. Once the controller is preparing to add your device, press the FIRST BUTTON(ONLY) 5 times, LED flashes in blue during inclusion and the LED stays on green for 2 seconds after inclusion successfully. If the LED flashes purple for 3 seconds, please reset the device. LED will stay on red for 2 seconds after inclusion failed.

To remove the device

  1. Follow the instructions for your Z-Wave-certified controller to remove a device from the Z-Wave network.
  2. Once the controller is preparing to remove your device, press the SECOND BUTTON(ONLY) 5 times, the LED flashing in purple during the exclusion and the LED stays on green for 2 seconds after the exclusion successfully. LED will stay red for 2 seconds after exclusion failed.

Wake up the Device

Press the THIRD button 5 times quickly, LED will stay solid on blue when awake and will turn off when the device goes back to sleep mode.

Factory Reset

Manual: Press the Fourth button 5 times, LED flashing red 5S while pressing 5 times again, LED will stay red for 2 seconds and then off.

Note:  Install the custom device handler to access the right functions if you’re using the SmartThings hub. Please visit our website: www.minoston.com or email us: ask@minoston.com.

Configuration Parameter

  • Parameter 1 Battery report threshold % Use it to set battery level for battery reports. size=1 byte Available range : 1-20 (DEFAULT): 10%
  • Parameter 2 Low Battery alarm report Use it to set battery level for low battery reports. size=1 byte Available range : 5%-20% (DEFAULT) : 5%
  • Parameter 3 LED Indicator Color for First button remote control (Scene 1 activation) Choose the LED indicator color for First button remote control triggers size=1 byte Available settings: 0–6
    • Value=0 White
    • Value=1 Purple
    • Value=2 Orange
    • Value=3 Cyan
    • Value=4 Red
    • Value=5 Green
    • Value=6 Blue
    • (DEFAULT) : 0
  • Parameter 4 LED Indicator Color for Second button remote control (Scene 2 activation) Choose the LED indicator color for Second button remote control triggers size=1 byte Available settings: 0–6
    • Value=0 White
    • Value=1 Purple
    • Value=2 Orange
    • Value=3 Cyan
    • Value=4 Red
    • Value=5 Green
    • Value=6 Blue
    • (DEFAULT) : 1
  • Parameter 5 LED Indicator Color for Third button remote control (Scene 3 activation) Choose the LED indicator color for Thrid button remote control triggers size=1 byte Available settings: 0–6
    • Value=0 White
    • Value=1 Purple
    • Value=2 Orange
    • Value=3 Cyan
    • Value=4 Red
    • Value=5 Green
    • Value=6 Blue
    • (DEFAULT) : 2
  • Parameter 6 LED Indicator Color for Fourth button remote control (Scene 4 activation) Choose the LED indicator color for Fourth button remote control triggers size=1 byte Available settings: 0–6
    • Value=0 White
    • Value=1 Purple
    • Value=2 Orange
    • Value=3 Cyan
    • Value=4 Red
    • Value=5 Green
    • Value=6 Blue
    • (DEFAULT) : 3
  • Parameter 7 LED Indicator Brightness Choose the LED indicator Brightness level size=1 byte Available settings: 0–10
    • Value=0 LED off
    • Value=1 10% Brightness
    • Value=2 20% Brightness
    • Value=3 30% Brightness
    • Value=4 40% Brightness
    • Value=5 50% Brightness
    • Value=6 60% Brightness
    • Value=7 70% Brightness
    • Value=8 80% Brightness
    • Value=9 90% Brightness
    • Value=10 100% Brightness
    • (DEFAULT) : 5

Scene Control

This remote supports four scene controls

  • Scene 1 : First Button 1-Tap/2-Tap/3-Tap/Held/Released
  • Scene 2 : Second Button 1-Tap/2-Tap/3-Tap/Held/Released
  • Scene 3 : Third Button 1-Tap/2-Tap/3-Tap/Held/Released
  • Scene 4 : Fourth Button 1-Tap/2-Tap/3-Tap/Held/Released

Association Group

This remote supports 9 Association Group controls Support group number: 9 Each group max. Support 10 devices

  • Group 1 Lifeline
  • Group 2 First button press 1x send basic set 0xff, Second button press 1x send basic set 0x00.
  • Group 3 Third button press 1x send basic set 0xff, Fourth button press 1x send basic set 0x00
  • Group 4 First button holds more than 0.5s send SWITCHMULTILEVEL
    • START_LEVEL_CHANGE(Dim Up)
    • First button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
    • The second button holds more than 0.5s send SWITCHMULTILEVEL
    • START_LEVEL_CHANGE(Dim Down)
    • Second button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
  • Group 5 Third button holds more than 0.5s send SWITCHMULTILEVEL
    • START_LEVEL_CHANGE(Dim Up)
    • Third button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
    • The fourth button holds more than 0.5s send SWITCHMULTILEVEL
    • START_LEVEL_CHANGE(Dim Down)
    • Fourth button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
  • Group 6 First button press 1x to toggle on/off (send basic set 0xff or 0x00).
  • Group 7 Second button press 1x to toggle on/off (send basic set 0xff or 0x00).
  • Group 8 Third button press 1x to toggle on/off (send basic set 0xff or 0x00).
  • Group 9 Fourth button press 1x to toggle on/off (send basic set 0xff or 0x00).

Command Class
Generic Device Class: 0x07 – GENERIC_TYPE_SENSOR_NOTIFICATION
Specific Device Class: 0x01 – SPECIFIC_TYPE_NOTIFICATION_SENSOR

Command Classes:

  • 0x5E – COMMAND_CLASS_ZWAVEPLUS_INFO
  • 0x85 – COMMAND_CLASS_ASSOCIATION
  • 0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
  • 0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
  • 0x31 – COMMAND_CLASS_SENSOR_MULTILEVEL
  • 0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
  • 0x86 – COMMAND_CLASS_VERSION
  • 0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
  • 0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
  • 0x73 – COMMAND_CLASS_POWERLEVEL
  • 0x80 – COMMAND_CLASS_BATTERY
  • 0x9F – COMMAND_CLASS_SECURITY_2
  • 0x71 – COMMAND_CLASS_NOTIFICATION
  • 0x87 – COMMAND_CLASS_INDICATOR
  • 0x30 – COMMAND_CLASS_SENSOR_BINARY
  • 0x70 – COMMAND_CLASS_CONFIGURATION
  • 0x84 – COMMAND_CLASS_WAKE_UP
  • 0x6C – COMMAND_CLASS_SUPERVISION
  • 0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD

FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,
(2) This device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer-ence to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following meas-ures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environ-ment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.

CAUTION – PLEASE READ!

This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation consult a qualified electrician.

MEDICAL EQUIPMENT
Please DO NOT use this plug to control Medical or Life Support equipment. This device should never be used to control the On/Off status of Medical and/or Life Support equipment.

OTHER WARNINGS
Risk of Fire / Risk of Electrical Shock / Risk of Burns

IMPORTANT SAFETY INSTRUCTIONS

  1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
  2. Read and follow all instructions that are on the product or provided with the product.
  3. do not use an extension cord.
  4. Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring
  5. andclearances from power and lighting conductors.
  6. Installation work and electrical wiring must be done by qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction.
  7. do not install or use within 10 feet of a pool
  8. do not use in a bathroom

Risk of Electric Shock.
When used outdoors, install only to a covered Class A GFCI protected receptacle that is weatherproof with the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power unit andcord do not interfere with completely closing the receptacle cover.

WARNING:
Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface

WARNING:
Risk of Electric fire. install only to a receptacle protected by 20A branch circuit over current protection.