Ubiquiti ER-4 EdgeRouter User Guide

June 13, 2024
UBIQUITI

Ubiquiti ER-4 EdgeRouter

ubiquiti-er-4-edgerouter-PRODUCT

PACKAGE CONTENTS

ubiquiti-er-4-edgerouter-FIG- \(1\)

Installation Requirements

  • Drill with a 6 mm drill bit (for wall mounting)
  • Phillips screwdriver
  • For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.
  • We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable

WARNING: To reduce the risk of fire or electric shock, do not expose the EdgeRouter to rain or moisture.
Note: Although the cabling can be located outdoors, the EdgeRouter itself should be housed inside a protective enclosure.

Note: The System LED functionality has been updated with firmware v1.10.7. We recommend that you update the EdgeRouter to the latest firmware.

ubiquiti-er-4-edgerouter-FIG- \(2\)

  System LED

Flashing White| Bootup in progress.

White

| Ready for use, not connected to Ubiquiti® Network Management System (UNMS™).
Blue| Ready for use, connected to UNMS.
Steady Blue with Occasional Flashing| Ready for use, unable to connect to UNMS, check connection to UNMS server.
Quickly Flashing Blue| Used to locate a device in UNMS.
Alternating Blue/White| Firmware upgrade in progress.
  RJ45 Speed/Link/Act LED (0 – 2)
Off| No Link
Amber| Link Established at 10/100 Mbps
Amber Flashing| Link Activity at 10/100 Mbps
Green| Link Established at 1000 Mbps (1 Gbps)
Green Flashing| Link Activity at 1000 Mbps (1 Gbps)
  SFP Link/Act LED (3)
Off| No Link
Green| Link Established at 1 Gbps
Green Flashing| Link Activity at 1 Gbps
RJ45 serial console port for Command Line Interface (CLI) management. Click for         ×

ble oUf SCBontents
Reserved for future use.
  RJ45 Ports (eth0 – eth2)
RJ45 ports support 10/100/1000 Ethernet connections.
  SFP Port (eth3)
SFP port is hot-swappable and supports Gigabit fiber SFP modules.
  Reset Button
Click here to learn how to reset an EdgeRouter to factory defaults.

RJ45 serial console port for Command Line Interface (CLI) management.

Hardware Installation

WARNING
FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARDS. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW.

Wall Mounting

ubiquiti-er-4-edgerouter-FIG- \(3\)ubiquiti-er-4
-edgerouter-FIG- \(4\)ubiquiti-er-4-edgerouter-FIG-
\(5\)ubiquiti-er-4-edgerouter-FIG-
\(6\)

Grounding the EdgeRouter (Recommended)
The Power Cord grounds the device; however, you can add optional ESD grounding for enhanced ESD protection.

  1. Attach a screw (not included) to secure a ground wire (not included) to the Grounding Point.ubiquiti-er-4-edgerouter-FIG- \(7\)
  2. Secure the other end of the ground wire to a grounding block.

Connecting Power
Connect the Power Cord to the Power port and a power outlet.

ubiquiti-er-4-edgerouter-FIG- \(8\)

Using SFP Ports

ubiquiti-er-4-edgerouter-FIG- \(9\)

For information about compatible fiber SFP modules, visit ubnt. link/SFP_DAC_Compatibilityubiquiti-er-4-edgerouter-FIG-
\(10\)

Accessing the EdgeOS Configuration Interface

The EdgeOS® configuration interface can be accessed via DHCP or static IP address assignment. By default, eth1 is set up as a DHCP client, while eth0 is assigned a static IP address of 192.168.1.1. To configure the EdgeRouter, proceed to the appropriate section: DHCP or “Static IP Address”.

DHCP

  1. Connect an Ethernet cable from eth1 on the EdgeRouter to a LAN segment that has an existing DHCP server.ubiquiti-er-4-edgerouter-FIG- \(11\)
  2. To check the IP address of the EdgeRouter, use one of the following methods:
    • Set up the DHCP server to provide a specific IP address to the EdgeRouter based on its MAC address (on the label).ubiquiti-er-4-edgerouter-FIG- \(12\)
    • Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned.ubiquiti-er-4-edgerouter-FIG- \(13\)
  3. Launch your web browser. Enter the appropriate IP address in the address field. Press enter (PC) or return (Mac).ubiquiti-er-4-edgerouter-FIG- \(14\)
  4. Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

  1. Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0 × on the EdgeRouter.
  2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
  3. Launch your web browser. Type https://192.168.1.1 in the address field. Press enter (PC) or return (Mac).
  4. Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

Specifications

ER-4

Dimensions| 229 x 136.5 x 31.1 mm

(9.02 x 5.37 x 1.22″)

Weight| 795 g (1.75 lb)
Max. Power Consumption| 13W
Power Method| Universal AC Power Cord (C13)
Power Supply| Internal AC/DC Power Adapter, 30W DC
Supported Voltage Range| 100-240VAC, 50/60 Hz Universal Adapter
Button| Reset
LEDs

Data Ports SFP Data Port

|

Speed/Link/Activity

Link/Activity

Processor| 4-Core 1 GHz MIPS64
System Memory| 1 GB DDR3 RAM
On-Board Flash Storage| 4 GB eMMC, 8 MB SPI NOR
ESD/EMP Protection| Air: ± 24 kV, Contact: ± 24 kV
Interfaces|
Management| (1) RJ45 Serial Port
 | (4) Ethernet Ports (Default eth0)
Networking| (3) 10/100/1000 RJ45 Ports
 | (1) 1 Gbps SFP Port
Operating Temperature| -10 to 50° C (14 to 122° F)
Operating Humidity| 10 – 90% Noncondensing
Certifications| CE, FCC, IC

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Failure to provide proper ventilation may cause a fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose a fire hazard if the limitations are not followed.
  2. There are no operator-serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    • Do not substitute the power cord with one that is not the approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    • The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    • Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    • Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    • Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warranty

The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning : This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.

CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
WEEE Compliance Statement
Declaration of Conformity

Online Resources

ubiquiti-er-4-edgerouter-FIG- \(15\)

2021 Ubiquiti Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals