MEAN WELL GSM160B Series 160W AC-DC Reliable Green Medical Adaptor Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
MEAN WELL GSM160B Series 160W AC-DC Reliable Green Medical Adaptor
Specifications
- Power: 160W
- Input: 100-240VAC, 1.85A / 115VAC, 1A / 230VAC
- Output: Please refer to the manual for detailed output specifications
- Safety Standards: IEC60601-1, BS EN/EN60601-1, ANSI/AAMI ES60601-1
- Isolation Level: 2xMOPP
- Withstand Voltage : I/P-O/P: 4KVAC
Product Usage Instructions
- Features
- 2 pole AC inlet IEC320-C8, Class power unit
Extremely low leakage current
- No load power consumption 110 K hours
- Various DC plug quick adapter accessories available (Plug kit sold separately)
- 3 years warranty
Applications
- Mobile clinical workstation
- Medical safety approved for oral irrigator
Temperature & Humidity
- Operating Temperature: -30°C to +70°C
- Working Humidity: 20% to 90% RH non-condensing
- Storage Temp., Humidity: -40°C to +85°C, 10% to 95% RH non-condensing
Safety Standards & EMC Compliance
- Meets various safety and EMC standards including IEC60601-1, BS EN/EN60601-1, ANSI/AAMI ES60601-1
Features
-
2 pole AC inlet IEC320-C8, Class 11 power unit
-
Medical safety approved (2 x MOPP) according to
ANSI/AAMI ES60601-1/-1-11 and IEC/BS EN/EN60601-1/-1-11 -
Extremely low leakage current
-
No load power consumption<0.15W
-
Energy efficiency level VI and meet CoC Version 5
-
-30~+70°C wide range working temperature
-
Protections: Short circuit / Overload / Over voltage / Over temperature
-
LED indicator for power on
-
Lifetime > 110 K hours
-
Various DC plug quick adapter accessory available (Plug kit sold separately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
-
3 years warranty
Applications
- Mobile clinical workstation
- Oral irrigator
- Portable hemodialysis machine
- Breath Machine
- Medical comouter monitor
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
GSM160B is a highly reliable, 160W desktop-style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra-low leakage current (<100mA), fitting the medical devices in direct electrical contact with the patients.
With an efficiency up to 94% and an extremely low no-load power consumption below 0.15W, GSM160B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP, and meets Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save energy when it is either in the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM160B is approved with international medical safety certificates.
Model Encodine
SPECIFICATION
ORDER NO.| GSM160B12- R7B| GSM160B15- R7B|
GSM160B20- R7B| GSM160B24- R7B| GSM160B48- R7B
---|---|---|---|---|---
OUTPUT
| SAFETY MODEL NO.| GSM160B12| GSM160B15| GSM160B20| GSM160B24|
GSM160B48
DC VOLTAGE **Note.2| 12V| 15V| 20V| 24V| 48V
RATED CURRENT| 11.5A| 9.6A| 8A| 6.67A| 3.34A
CURRENT RANGE| 0 ~ 11.5A| 0 ~ 9.6A| 0 ~ 8A| 0 ~ 6.67A| 0 ~ 3.34A
RATED POWER (max.)| 138W| 144W| 160W| 160W| 160W
RIPPLE & NOISE (max.) Note.3| 80mVp-p| 100mVp-p|
120mVp-p| 120mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3%
LINE REGULATION ****Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±4.0%| ±3.0%| ±3%
SETUP, RISE TIME ****Note.6| 2000ms, 50ms / 230VAC
2500ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 24ms / 230VAC 24ms / 115VAC at
full load
INPUT
| VOLTAGE RANGE **Note.7| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| 12V/15V:PF>0.93 / 230VAC
20V,24V,48V:PF>0.94 / 230VAC PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)| 90%| 91%| 92.5%| 93.5%| 94%
AC CURRENT (Typ.)| 1.85A / 115VAC 1A / 230VAC
INRUSH CURRENT (Typ.)| Cold start 90A / 115VAC 110A /
230VAC
LEAKAGE CURRENT(max.)**| Touch current < 100 A/264VAC
PROTECTION
|
OVERLOAD
| 105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0 ~ 40℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
OPERATING ALTITUDE Note.8| 3000 meters
SAFETY & EMC
(Note. 9)
| SAFETY STANDARDS| IEC60601-1/IEC60601-1-11, BS EN/EN60601-1/ BS
EN/EN60601-1-11, ANSI/AAMI ES60601-1 / ES60601-1-11(3.1 version),
CAN/CSA-C22.2 No. 60601-1:14 – Edition 3, EAC TP TC 004 approved
ISOLATION LEVEL| Primary-Secondary: 2xMOPP
WITHSTAND VOLTAGE| I/P-O/P: 4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN
ICES-3(B)/NMB-3(B)| Class B
Radiated emission| BS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22, CAN
ICES-3(B)/NMB-3(B)| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN60601-1-2, BS EN/EN61204-3
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 3, 1KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption
|
BS EN/EN61000-4-11
| 100% dip 1 periods, 30% dip 25 periods,
100% interruptions 250 periods
OTHERS
| MTBF| 2191.3K hrs min. Telcordia SR-332 (Bellcore) ; 239.1K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1757235mm (LWH)
PACKING| 0.66Kg; 20pcs/14.2Kg/0.95CUFT
CONNECTOR| PLUG| See page 4~5; Other type available by customer
requested
CABLE| See page 4~5; Other type available by customer requested
NOTE
- All parameters are specified at 230VAC input, rated load, 25 C 70% RH ambient.
- DC voltage: The output voltage set at the point measured by the plug terminal & 50% load.
- Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1 F & 47 u F capacitor.
- Tolerance: includes set up tolerance, line regulation, and load regulation.
- Line regulation is measured from the low line to the high line at the rated load.
- The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.
- Derating may be needed under low input voltage. Please check the derating curve for more details.
- The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitudes higher than 2000m(6500ft).
- The power supply is considered as an independent unit, but the final equipment still needs to confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com/Upload/PDF/EMI_statement_en.paf)
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Dimension
- Derating Curve
- Static Characteristics
Mechanical Specification
DC output plug
- Standard plug: R7B
DC plug changeable through:
- Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide: https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:
Optional DC plug: (Available in customized cable or quick adapter)
Installation
Manual
Please refer to: http://www.meanwell.com/manual.html
Downloaded from Arrow.com
QR SCAN
FAQ
- Q: Can I use this adaptor for non-medical devices?
- A: While it is designed for medical applications, it can be used for other devices within its power rating.
- Q: Is the DC plug kit included with the adaptor?
- A: No, the DC plug kit is sold separately. You can refer to the provided link for more information.
- Q: What is the warranty period for this product?
- A: The product comes with a 3-year warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>