MEAN WELL SUS01 Series 1W DC-DC Unregulated Single Output Converter Owner’s Manual

June 13, 2024
MEAN WELL

1W DC-DC Unregulated Single Output Converter
SUS01 series

Features:

  • 1000VDC I/O isolation
  • Internal SMD technology
  • Built-in EMI filter
  • Cooling by free air convection
  • Non-conductive plastic case
  • Dual in line package
  • 100% burn-in test
  • Low cost / High reliability
  • Approvals: FCC /EAC/CE/UKCA
  • 2 years warranty

SELECTION GUIDE

ORDER NO.| SUSO1L-05| SUSO1M-05| SUSO1N-05| SUS010-05| SUSO1L-09| SUSO1M-09| SUSO1N-09| SUS010-09
---|---|---|---|---|---|---|---|---
| DC OUTPUT VOLTAGE| 5V| 9V
OUTPUT CURRENT RANGE| 0 – 200mA| 0 – 111mA
EFFICIENCY| 73%| 74%| 72%| 74%| 75%| 79%| 80%| 77%
ORDER NO.| SUSO1L-12| SUSO1M-12| SUSO1N-12| SUS010-12| SUSO1L-15| SUSO1M-15| SUSO1N-15| SUS010-15
---|---|---|---|---|---|---|---|---
| DC OUTPUT VOLTAGE| 12V| 15V
OUTPUT CURRENT RANGE| 0 – 84mA| 0 – 67mA
EFFICIENCY| 78% I82% I83%| 83%| 79% 182%| 83%| 83%

SPECIFICATION

OUTPUT RATED POWER 1W
RIPPLE & NOISE (max.) Note.2 100mVp-p
LINE REGULATION Note.3 ±1.2% for 1% input variation
LOAD REGULATION Note.4 ±8.0%
VOLTAGE ACCURACY ±2.0%
SWITCHING FREQUENCY 50KHz min.
INPUT VOLTAGE RANGE 4.5 – 5.5V
– 5.5V 10.8 -13.2V 21.6 – 26.4V
NORMAL VOLTAGE 5V 12V
INPUT CURRENT Full load 280mA
No load 21mA 11mA
FILTER Capacitor type
PROTECTION Fuse recommended
PROTECTION OVERLOAD Momentary

Protection type : Broken
SHORT CIRCUIT
Momentary|
Protection type : Broken
ENVIRONMENT| WORKING TEMP.| -25 – +71 c (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -25 – +105 c , 10 – 95% RH
TEMP. COEFFICIENT| ±0.03% / t (0 – 50’C)
VIBRATION| 10 – 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE| 1113-0/P:1.5KVOC
ISOLATION RESISTANCE| IIP-0/P: 100M Ohms / 500VDC/ 25°C/ 70% RH
ISOLATION CAPACITANCE| 80pF max.
EMC EMISSION| Compliance to BS EN/EN55032 Class B, FCC part 15 Class B, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
OTHERS| MTBF| 700khrs min. MIL-HDBK-217F(25°C)
DIMENSION| 22.6’9.91.9mm or 0.89’1’0.39’1’0.35′ inch (L’W*H)
WEIGHT| 3.1g

Mechanical Specification

Pin Configuration

Pin No. Output
1 & 16 +Vin
6 & 11 -Vout
7 & 10 +Vout
8  &  9 -Vin

Derating Curve

NOTE

  1. All parameters are specified at normal input, rated load, 25’C 70% RH ambient.
  2. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a O.1uf & 47uf capacitor.
  3. Line regulation is measured from low line to high line at rated load.
  4. Load regulation is measured from 20% to 100% rated load.
    Product Liability Disclaimer : For detailed information, please refer to https://vww.meanwell.com/serviceDisclaimer.aspx

File Name: SUS01-SPEC 2022-03-16

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>