Danfoss 088U1110 Icon Floor Sensor User Manual

June 11, 2024
Danfoss

Danfoss 088U1110 Icon Floor Sensor User Manual

Instruction

Use conduit systems for electrical installations acc. to EN/IEC 61386-23

The floor sensor must be mounted in a insulating conduit, sealed at the floor end (1), for easy replacement of the floor sensor if necessary.

The minimum bending radius is 5 cm (2).

The best placement for the floor sensor, is centered between two floor heating loops (3).

The floor sensor is a LIVE cable; therefore any extension made to the sensor wiring should be treated in the same way as normal main voltage cabling.

Type: NTC 47 kΩ / 25˚C, 3 m

13690 000 01 Manual Installation SC 3 Metre Danfoss / VISUK20F
Metre Danfoss

Documents / Resources

| Danfoss 088U1110 Icon Floor Sensor [pdf] User Manual
088U1110 Icon Floor Sensor, 088U1110, Icon Floor Sensor, Floor Sensor, Sensor
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals