Quantek ML8 RB3 KIT Control Panel User Manual
- June 13, 2024
- QUANTEK
Table of Contents
- Quantek ML8 RB3 KIT Control Panel
- Product Information
- Product Usage Instructions
- Maintenance
- Technical Data
- Connection
- Installation
- Programming
- Safety devices programming
- Maneuver programming
- Inputs, outputs, dip-switches & radio inputs
- Regulatory Data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Quantek ML8 RB3 KIT Control Panel
Product Information
Section | Page Number |
---|---|
Maintenance | 3 |
Important safety instructions for installation | 3 |
Important safety instructions for use | 3 |
Use of the equipment | 3 |
Technical Data | 4 |
Connection | 5 |
Installation | 6 |
Programming | 7-9 |
Inputs, outputs, dip-switches & radio inputs | 10 |
Regulatory Data | 10 |
Product Usage Instructions
Installation
To install the product with support:
- Unscrew the support.
- Extract the support.
- Drill the wall.
- Hang the control panel on the wall.
- Screw the control panel.
To install the product without support:
- Unscrew the top of the control panel.
- Open the top.
- Drill the wall.
To position the door:
- When the door is opened, press and hold the close button until the door closes.
- When the door is closed, press and hold the open button until the door opens.
Programming
To manually program radio devices (remote controls, wireless buttons, etc.):
- Open the top of the control panel.
- Press the red RPROG pushbutton. The LED turns on.
- Press the transmitter button.
- Press the RPROG pushbutton. The LED turns off.
To perform a total reset:
- Open the top of the control panel.
- Press and hold the RPROG pushbutton.
- Bridge MR and wait for several beeps.
- Release the RPROG pushbutton.
- The LED turns off.
To program safety devices:
- Wire in the safety edge and set the dipswitches according to the RB3 TGL868 manual before programming.
- Press the PROG button of the plugable card RSEC3. The LED turns on.
- Press the PROG transmitter button. One beep indicates programming is successful.
- The LED turns off.
- Slide the cover to close.
To program the door maneuver:
- Ensure the door is closed.
- Press the white PROG pushbutton. The LED turns on.
- Press the start pushbutton. The door opens for 2 seconds and then closes.
- The door stops in auto mode.
- The door opens in auto mode.
- The door stops in auto mode.
- Set the autoclose time.
- Press the start pushbutton. The door closes and stops in auto mode.
- The LED turns off. Programming is complete.
Inputs, outputs, dip-switches & radio inputs
The product comes with factory default settings. All settings and parameters
can be modified with the VERSUS-PROG programming tool. Please refer to the
VERSUS manual for a full list of available settings and their definitions.
Regulatory Data
EU Declaration of conformity can be found on page 10 of the user manual.
Maintenance
Important safety instructions for installation
Disconnect the power supply whenever you proceed to the installation or repair of the control panel.
- The panel must be installed while the power is disconnected.
- Before installing the panel, remove all unnecessary ropes or chains and disable any equipment such as locks that is not necessary for the automatic operation.
- Before installing the panel, check that the door is in good mechanical condition, correctly balanced and that it opens and closes correctly.
- Install the manual unlocking device at a height lower than 1.8m.
- Install any permanent control next to the door away from any moving part and at a minimum height of 1.5m.
- For permanently connected equipment, an easily accessible power disconnection device must be incor- porated into the wiring. It is recommended that this be of the emergency switch type.
- If the control panel is supplied without emergency stop button, this will be incorporated in the installation, connecting it to the STOP terminal.
- For correct use of the security edge, this must never be activated when the door is fully closed. It is wise to install the ends of run before activating the edge.
- This equipment can only be handled by a specialist fitter, by maintenance staff or by a suitably trained operator.
- To connect the power supply and motor wiring, 2.5 mm2 section terminals must be used.
- Use protective goggles when handling the equipment.
- Fuses must only be handled when the appliance is disconnected from the mains.
- The instructions for using this equipment must remain in the possession of the user.
- European door normative EN 12453 and EN 12445 specify the following minimum protection and door safety levels:
- for single-family dwellings, prevent the door from making contact with any object or limit the force of con- tact (e.g. safety band), and in the case of automatic closing, it is necessary to complement this with a pres- ence detector (e.g. photocell).
- for communal and public installations, prevent the door from making contact with any object or limit the force of contact (e.g. safety band), and complement this with a presence detector (e.g. Photocell).
Important safety instructions for use
- Do not allow children to play with the door controls.
- Keep the remote controls out of the reach of children.
- Watch the door movement and keep people away until the door is fully open or closed.
- Precaution when operating the manual unlocking device, as the door may suddenly fall due to the bad condition of the springs or door unbalance. Details on how to use the manual unlocking device must be provided by the manufacturer or the device installer.
- Examine the installation frequently, especially the cables, springs and supports, to detect signs of wear, damage or unbalance. Do not use the door if repair work or adjustments are required, as this may cause damage.
Use of the equipment
Designed for automation of garage doors, in accordance with the general
description. Not guaranteed for other uses. The man- ufacturer reserves the
right to alter equipment specifications without prior notification.
Technical Data
Parameter/Value
- Frequency 868,35 MHz
- Codification High security rolling code
- Memory 27 codes (expandable to 500 codeswith memory card)
- Power supply 230Vac ±10%
- Maximum motor power 750W / 1200W (intensive use / residential use)
- Standby /operating consumption 23mA /43mA
- Motor fuses 6A
- Optional cards RSEC3 +MEM500 +V-XPAN + TL-CARD-V
- Free voltage output 2 outputs
- 12Vdc output 1 fix (100mA) + 1 configurable (100mA)
- Manoeuvre time 1 second – 6minutes
- Operating temperature -20ºCto +55ºC
- Watertighness IP32
- Size 180 x 152 x 88mm
Connection
Motor connections:
- U=OPEN (Brown)
- V=CLOSE (Black)
- W(c)=COMMON (Blue)
Installation
Installation with support
Installation without support
Door Positioning
Programming
Radio Manual Programming (Remote controls, wireless buttons, etc)
NOTE:
To program transmitters onto different channels, press and hold the red RADIO
PROG pushbutton until the LED for that channel turns on, then release the
RADIO PROG pushbutton and press the transmitter.
Total Reset
Safety devices programming
RadioBand3 Transmitter Programming in RSEC3 Receiver
Wire in the safety edge and set the dipswitches according to the RB3 TGL868
manual before programming.
Maneuver programming
Programming the door maneuver
Inputs, outputs, dip-switches & radio inputs
- Factory default settings. All the below can be modified with the VERSUS-PROG programming tool. If they are modified, please ensure this manual and the sticker on the inside of the control panel cover is updated.
- For a full list of the settings & parameters available and their definitions, please refer to the VERSUS manual.
OUTPUTS
OUT1| FLASH|
OUT2| COURTESY LIGHT LEVEL|
OUT19| AUTOTEST SIGNAL|
DIPSWITCH OPTIONS
SW1| AUTOCLOSE|
SW2| DEADMAN|
SW3| PRE-FLASH|
SW4| SEC. CLOSE TEST|
INPUTS
IN1| SEC. CLOSE AUTOTEST (NC)|
IN2| START (NO)|
IN3| STOP (NC)|
RADIO INPUTS
IN31 (C1)| START RADIO SEC_DM|
IN32 (C2)| DEAD MAN CLOSE|
IN33 (C3)| OPEN|
IN34 (C4)| CLOSE|
Regulatory Data
EU Declaration of conformity
JCM Technologies hereby declares that the product M8NF complies with the relevant fundamental requirements of the RED Directive 2014/53/EU, as well as with the Machine Directive 2006/42/EC whenever its usage is foreseen; and with the 2011/65/EU RoHS Directive. See website www.jcm- tech.com/declarations/.
JCM TECHNOLOGIES, SA
C/COSTA D’EN PARATGE, 6B 08500 VIC (BARCELONA) SPAIN.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>