SAL S9073TC-WH-DP Premier LED Downlight User Manual

June 13, 2024
SAL

S9073TC-WH-DP Premier LED Downlight

IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and AS/NZS Standards, which require installation in
accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are
sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and
or technical performance guarantee unless expressly confirmed in writing by SAL at the time of order.

PREMIER S9073TC S9074TC S9075TC S9076TC LED DOWNLIGHT electrical and installation specification effective 24/5/2023.

Model No.

|

Input

(V)/(Hz)

|

Power  (W)

|

Lumens (lm)

|

Line Current (A)

|

In-rush Current

|

Fitting

Colour

|

CRI

|

Dimmable

|

Mass

(N.W. kg)

|

Cutout

Size (mm)

|

Dimension  (mm)

---|---|---|---|---|---|---|---|---|---|---|---

S9073TC/WH/DP

|

220-240/50

|

13

18

|

1100/1300/1000 1500/1800/1600

|

0.05

0.08

|

10A Max.@230Vac, < 200µS at

50% Ipeak

|

White

|

80

|

 Yes

|

0.35

|

Ø135

|

Ø165 x H63

S9073TC/SL/DP

|

220-240/50

|

13

18

|

1100/1300/1000 1500/1800/1600

|

0.05

0.08

|

Silver

|

80

|

 Yes

|

0.35

|

Ø135

|

Ø165 x H63

S9074TC/WH/DP

|

220-240/50

|

15

20

|

1200/1400/1300 1600/1900/1700

|

0.06

0.08

|

White

|

80

|

No

|

0.45

|

Ø160

|

Ø200 x H68

S9075TC/WH/DP

|

220-240/50

|

23

30

|

2000/2300/2100 2600/3100/2800

|

0.10

0.13

|

20A Max.@230Vac, < 400µS at

50% Ipeak

|

White

|

80

|

 No

|

0.55

|

Ø195

|

Ø230 x H75

S9076TC/WH/DP

|

220-240/50

|

30

40

|

2600/3100/2800 3500/4200/3800

|

0.13

0.17

|

White

|

80

|

No

|

0.7

|

Ø240

|

Ø280 x H96

S9074TC/WH/HP

|

220-240/50

|

 10

|

1000/1100/1000

|

0.04

|

10A Max.@230Vac,

|

White

|

80

|

Yes

|

0.45

|

Ø160

|

Ø200 x H68

S9075TC/WH/HP

|

220-240/50

|

 12

|

1300/1400/1400

|

0.05

|

< 200µS at

|

White

|

80

|

Yes

|

0.55

|

Ø195

|

Ø230 x H75

50% Ipeak

No Ø240 Ø280 x H96

S9076TC/WH/HP 220-240/50 180.08 White > 80 0.7 2100/2300/2200

Electrical class

|

Driver II, Fitting III

|

Beam Angle

|

90°

---|---|---|---

Power factor

|

0.9

|

Earth Leakage current

|

< 1mA

Operating ambient min/max (°C)

|

0 to 40

|

Storage ambient limit (°C)

|

0 to 60

Operating humidity

|

+10% to 85% RH, NC

|

Storage humidity

|

+10% to 85% RH, NC

Reported TM-21, 85 °C,L 90 (hrs)

|

36,000

|

Reported TM-21, 85 °C,L70 (hrs)

|

54,000

Aiming restrictions (if any)

|

N/A

|

Product application

|

Interior residential or commercial spaces

IK rating (if relevant)

|

N/A

|

Product installation orientation

|

Horizontal ceiling mount, recessed

CCT (K) switch control (TC)

|

Yes

|

CCT (K)

|

3000/4000/5700

Insulation cover rating (if any)

|

IC-4

|

PIXIE connectivity

|

Yes, switch & dimming where noted above

Replaceable LED

|

No (see clause 8)

|

IP rating

|

IP64 from below ceiling, IP20 from above ceiling

User replaceable LED

|

No (see clause 8)

|

Attachment type

|

Fitting Z, driver X

IP rating for interior products: The designated IP rating is “from below the ceiling” unless otherwise specified.

IP rating ALL products; Termination of the product must be made in accordance with the IP rating.

Earth Leakage current: Is calculated in accordance with AS/NZ 60598.1.2017/Amdt 1:2017.

General product application requirements (if applicable) :

1. CCT or POWER selections (where supplied) – IMPORTANT, where CCT colour temperature or POWER selection switching is provided, it is important to switch OFF the  power before the selection is made, otherwise equipment damage may occur.

2. Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.

3. Switching or test intervals – For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision  of a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications  and a six (6) hour duration for Residential applications should be considered.

4. Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that reflects the installation environment and maintains the product in a clean and functional condition.

IMPORTANT – The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the  product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an  equivalent cable exclusively available from the manufacturer or authorized installer. For attachment type Y, if the external flexible cable is damaged, it must be  exclusively replaced by an equivalent cable by the manufacturer or authorized installer. For attachment type Z, if the external flexible cable is damaged, the cable  cannot be replaced and the luminaire must be destroyed.

5. Adverse, corrosive and coastal installation environments – Unless the product is specifically designated for such applications in these installation instructions, which is supported by a professional maintenance program; installation of equipment in such environments is not recommended.

6. Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party changes in dimmer compatibility.

7. Suspended products – For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474

Copyright SAL V15 APR 2021 | www.sal.net.au | Page 1 of 2

8. Light source replacements – (Non-replaceable light sources) – The light source of the product is deemed not replaceable, when the product reaches its end of life the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) – The light source of the product must only be replaced by the manufacturer or qualified installer. Caution, risk of electric shock.

9. Interior downlights and sensors with remote drivers and electrical accessories – The mounting facilities provided for the transformer/driver (if any), need only be utilized  if in the application of the product is required by AS3000. Drivers are not designed for installation environments that restrict conventional airflow.

10. Floodlight products – Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and  15 metres in height, subject to the desired optical performance being achieved. For floodlight installation environments that have restricted access (eg: columns and  roof-lines) which are subject to unstable electrical supply or electrical surges (which void warranty), consideration of the installation of an independent surge protector is  strongly recommended.

11. Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific  emergency commissioning instructions, this battery MUST be connected at the time of installation.

12. Specific installation procedures (if any) – this device must be installed by a licensed electrician:

Building element above fitting

fitting

HCB – The minimum clearance distance from the top of the luminaire to any normally flammable building element

|

0 mm

---|---

MIC – The minimum clearance distance from the top of the luminaire to any building insulation

|

0 mm

SCB – The minimum clearance distance from the side of the luminaire to any normally flammable building element

|

0 mm

SCI – The minimum clearance distance from the side of the side of the luminaire to any building insulation

|

0 mm

SCG – Side clearance to auxiliary equipment control gear (CG) (if supplied)

|

50 mm

NOTE: (1) CG* – Remote control gear provided (if any) must not be covered.

NOTE: (2) IC ratings shown (if any) are made in accordance with AS/NZS6058 test procedures that stipulate the type of insulated material composition covering an IC-4  rated product being equivalent to formed insulation, where 200mm is equivalent to an R1 4.0 classification in accordance with AS/NZ4859.1.

13. Warranty – In accordance with SAL’s standard terms and conditions of sale, SAL warrant this product to be free from defects in materials and or workmanship for a  period as stated below for goods not subject to incorrect installation, maintenance, operation, mishandling, environmental, unauthorised modifications or electrical  operating conditions outside the nominated product specification as detailed in these installation instructions. The benefits to you given by this warranty are in addition to  other rights and remedies you have under law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a  replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or  replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Warranty term – Residential usage (60) months, Commercial usage (36) months and batteries where supplied (12) months from date of purchase. For New Zealand,  please refer to www.sal.co.nz for warranty conditions and service.

How to make a claim?

Step # 1 – Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following  information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.

Step # 2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;

NSW | ACT – SAL National Pty Ltd, 40 Biloela Street Villawood NSW 2163 | P # 02 9723 3099 QLD – SAL National Pty Ltd, 36 Whitelaw Place Richlands QLD 4077 | P # 07 3879 5999 VICT | TAS | SA | NT – SAL National Pty Ltd, 46-48 Keys Road Moorabbin Victoria 3189 | P # 03 9532 3168 WA – SAL National Pty Ltd, 29 Beringarra Av Malaga WA 6090 | P # 08 9248 7458 NZ – Hamer, 130 Bush Road, Albany, Auckland, 0632 | P # 0800 239 239

Step # 3 – Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be  returned to SAL as per the above nominated locations.

Step # 4 – Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the  discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of  installation, product removal, return freight and or testing fees are not the responsibility of SAL.

SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21 633 189 474 Copyright SAL V15 APR 2021 | www.sal.net.au | Page 2

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals