SAL PC100CS Pixie Contact Sensor Transceiver
Specifications:
- Model NO.: PC100CS/R/BTAM
- Attachments: Contact sensor (sold separately)
- Storage Humidity: 0 ~ 40
- Input Output IP Rating: 0 ~ 60
- Operation Humidity: 10% – 85% RH, NC
- Role in PIXIE System: Master
Product Introduction
The PIXIE Contact Sensor Transceiver is a smart device that monitors the open & closed status of gates/doors/windows using contact sensors. It sends push notifications to users via the PIXIE PLUS App when a status change occurs. These status changes can trigger advanced home automation functions within the system.
Product Features:
- Monitors open & closed status
- Push notifications via PIXIE PLUS App
- Integration with home automation functions
The package includes
Contact sensor (sold separately)
Installation and Wiring
Preparation:
- Select a suitable contact sensor (NC type) which consists of a reed switch and a magnet.
- Mount the reed switch on a fixed surface and the magnet on a moving part.
- Ensure the reed switch contact is closed when the gate/door is closed.
Installation:
- Mount the contact sensor at the desired position.
- Wire the PIXIE Contact Sensor Transceiver following the wiring diagram.
- Supply power to the transceiver and check the LED indicator is lit in white.
Note: Make sure to add the device into the App and finalize configuration following the guide provided in the App.
FAQ
Q: Can I use multiple contact sensors with one PIXIE Contact Sensor Transceiver?
A: Yes, you can use multiple contact sensors with one transceiver by adding them individually to the system through the App.
Q: What is the range of the wireless signal for the PIXIE Contact Sensor Transceiver?
A: The wireless signal range for the PIXIE Contact Sensor Transceiver is up to 40 meters in an open area.
Version 1.1
Date 15/12/2023
Foreword
IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE GUIDE AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and Australian Standards, which require installation in accordance with AS/NZS3000 by a qualified installer and regular cleaning and maintenance of the equipment. Products are sold in accordance with the following instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
Due to continued product and information updates, product data sourced from sal.net.au shall not form part of any contract and or technical performance guarantee unless expressly confirmed in writing by SAL at the time of order. The product wireframe drawings in this document are intended for illustration purposes only and may differ from the final physical product. The installation instruction is subject to change without prior notice.
Product Introduction
PIXIE Contact Sensor Transceiver is a smart device that monitors open & closed status of gates/doors/windows, via a set of contact sensors (sold separately). Push notification to users are delivered (PIXIE PLUS App only) when status change occurs. Any status change can be used as a trigger for logic control within the system to deliver more advanced home automation functions, e.g, if the door is open, then turn on a PIXIE smart switch.
Product Features
- Works with wired contact sensors (magnetic reed switches) for gates, doors and windows, to monitor open & closed status
- Connect with 1 set of contact sensor equals monitoring of 1 gate or door or window status
- In-built button for easy setup and control
- One RGB LED indicator to reflect different working modes and gate/door/win-dow status
The package includes
- PIXIE Contact Sensor Transceiver * 1
- Quick Start Guide *1
Product illustration
Specifications
Model NO. | PC100CS/R/BTAM | Input | 240V~ 50Hz |
---|---|---|---|
Attachments | Contact sensor (sold separately) | Output | Wireless |
signal
Operation Ambience Temperature (˚C)| ****
0 ~ 40
| ****
IP Rating
| ****
IP20
Storage Ambience Temperature (˚C)| ****
0 ~ 60
| ****
Operation Humidity
| ****
10% – 85% RH, NC
Storage Humidity| 10% – 85% RH, NC| Role in PIXIE System| Master
*All drawings shown are for illustration purpose only, actual product may vary due to product enhancement.
Installation and Wiring
Preparation
- Select suitable contact sensor (NC type), which comes as a pair, consisting of a reed switch and a magnet. The reed switch contact is closed when the magnet is present, and the contact opens when the magnet moves away.
- The reed switch comes with cable attached and is supposed to be mounted on a fixed surface, e.g. the ground, the wall, or a pole etc. The magnet is supposed to be mounted on a moving part
- Make sure the reed switch contact is closed when the gate/door is closed, and the contact is open when the gate/door is open.
Installation
- Mount the contact sensor onto the desired position
- Wire the PIXIE Contact Sensor Transceiver as per the wiring diagram on the right
- Supply power to the PIXIE Contact Sensor Transceiver, make sure the LED indicator is lit and in white colour
- Add this device into the App, follow the step-by-step guide in the App to finalise the configuration
** This product must be installed by a licensed electrician
Operation
Button operation
- Single click: Set the device to Armed mode, in which the device monitors the contact sensor status, and send out notification to the system if status changes
- Double Clicks: Set the device to Disarmed mode, in which the device does not monitor the contact sensor status
- 4 clicks: The device enters pairing mode, the LED indicator quickly flashes in blue and white for 30 seconds. This is for pairing the device to a PIXIE secondary device, so the working mode can be controlled by an extra device, typically a physical button on the wall for convenient control
- 9 clicks: Reset the device to factory default. The LED indicators flash in blue and white for 3 seconds then stay at white
The LED indicator
- The LED indicator is solid white colour when the device is new or factory reset
- The LED indicator is solid red colour when it’s in Armed mode, it’s high brightness when the contact sensor is in closed status, and low brightness when the contact sensor is in open status
- The LED indicator is solid green colour when it’s in Disarmed mode, it’s high brightness when the contact sensor is in closed status, and low brightness when the contact sensor is in open status
How to download App
- Scan QR code or go to App store (IOS) or Google Play (Android) to download the free PIXIE PLUS app to your smart phone.
- IOS: Requires IOS 6.0 or later. Compatible with iPhone, iPad and iPod touch.
- Android: Requires Android 4.4 or above, devices must support Bluetooth 4.0 or above.
- Specifications above are for reference only and may vary without prior notice.
Warranty
In accordance with SAL’s standard terms and conditions of sale, SAL warrant
this product to be free from defects in materials and or workmanship for a
period as stated below for goods not subject to incorrect installation,
maintenance, operation, mishandling, environmental, unauthorised modifications
or electrical operating conditions outside the nominated product specification
as detailed in these installation instructions.
The benefits to you given by this warranty are in addition to other rights and
remedies you have under law. Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You are entitled to a replacement
or refund for a major failure and compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure.
Warranty term – Residential usage (12) months, Commercial usage (12) months
How to make a claim?
- Step #1 – Within 30 days of the fault discovery, please contact the original place of the SAL product purchase during standard (local) business hours, with the following information (a) proof of purchase (b) description and quantity of the claimed fault (c) address of installation. (d) operating hours of the product.
- S tep #2 – It is then the responsibility of the original place of product purchase to report the matter to SAL aftersales;
- Step #3 – Upon review of your claim and if the product is required to be returned to SAL for technical evaluation, then at the owners expense the product must be returned to SAL as per the above nominated locations.
- Step #4 – Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the discretion of SAL, or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of installation, product removal, return freight and or testing fees are not the responsibility of SAL.
Scan QR code to access the full product information
References