COOLON ARIA X RGBW Light Instruction Manual
- June 13, 2024
- COOLON
Table of Contents
ARIA X
INSTALL ATION
INSTRUCTIONS
INCLUDED
Box Contents
- Luminaire
- Mounting Brackets (Integral)
+ Run Box
- Allen Key
- Cable Plastic Caps
- Cable Kits
CONTENTS | LxWxH DIMENSIONS |
---|---|
Single Luminaire | 582 x 191 x 121mm |
Double Luminaire | 637 x 249 x 151mm |
Triple Luminaire | 665 x 292 x 162.5mm |
Run Box | Varies depending on quantity |
ATTENTION
- Please observe / follow the instructions methodically.
- Please ensure the units are handled with extreme care.
- Do not remove product from packaging prematurely. Only remove from packaging when ready for installation.
- Failure to observe installation instructions and handling will void warranty of the product.
- Fittings must be installed by a licensed electrician.
- Before installing, make sure the power supply is switched off or mains cable is disconnected.
- Aria is designed for a wide range of applications, including those with low vibrations such as bridges and fixed metal structures. However, is not designed for heavy-duty environments with excessive vibration.
INSTALLATION LIMITS @ 230VAC
Maximum 40 x Single Luminaires per individual run.
INSTALLATION LIMITS @ 120VAC
Maximum 20 x Single Luminaires per individual run.
2mm distance between the ends of fittings to keep consistent LED pitch.
INSTALLATION LIMITS @ 230VAC
Maximum 20 x Double Luminaires fittings per individual run.
INSTALLATION LIMITS @ 120VAC
Maximum 10 x Double Luminaires per individual run.
INSTALLATION LIMITS @ 230VAC
Maximum 13 x Triple Luminaires per individual run.
INSTALLATION LIMITS @ 120VAC
Maximum 6 x Triple Luminaires per individual run.
WIRING CONFIGURATION
-
EXTENSION DATA 5,000mm
-
EXTENSION & LEADER KIT
• CBLKIT-MADA-L-5M -
EXTENSION MAINS 5,000mm
-
LEADER DATA 250mm
-
LEADER MAINS 400mm
-
EXTENSION KIT
• CBLKIT-MADA-J-0.6M (600mm)
• CBLKIT-MADA-J-5M (5,000mm)
• CBLKIT-MADA-J-CST (Custom Length) -
END-END INTEGRAL JUMPER
• Integral to 06 lengths only -
CAP
• CBLKIT-MADA-CAPS
DATA Pinouts
-
DATA F
OUTPUT -
DATA M
INPUT -
DMX +
Green / White -
DMX –
Green -
COMMON
Grey
MAINS Pinouts
-
POWER F
OUTPUT -
POWER M
INPUT -
ACTIVE
Black -
NEUTRAL
White -
EARTH
Green
WIRING DIAGRAMS
DALI INSTALLATION
- DALI
- MAINS LEADER
- EXTENSION
¹ Control limits defined by the DALI system
0-10V INSTALLATION
- 0 – 10V
- MAINS LEADER
¹ Single luminaire control
CASAMBI INSTALLATION
- CBU-A2D
- OTHER CASAMBI DEVICES
- DMX LEADER
- MAINS LEADER
- EXTENSION
¹ Please refer to Casambi’s documentation about system limits and range
² Please refer to CBU-A2D documentation for reference
³ Control limits defined by the DALI system
- Termination Caps
CONNECTION
Before installation begins, please ensure that you understand the fitting layout as per luminaire schedule.
CLICK!
DIMENSIONS
Single Luminaire
- 150mm minimum clearance required for full rotation
- 200mm minimum clearance required for full rotation
Double Luminaire
- 220mm minimum clearance required for full rotation
- 200mm minimum clearance required for full rotation
Triple Luminaire
- 315mm minimum clearance required for full rotation
- 300mm minimum clearance required for full rotation
DIMENSIONS WITH GLARE SHIELD
Single Luminaire
- 176mm minimum clearance required for full rotation
- 220mm minimum clearance required for full rotation
Double Luminaire
- 220mm minimum clearance required for full rotation
- 200mm minimum clearance required for full rotation
Triple Luminaire
- 315mm minimum clearance required for full rotation
- 300mm minimum clearance required for full rotation
MOUNTING FOOTPRINTS
Single Luminaire
MINIMUM RECOMMENDED FASTENERS PER LUMINAIRE:
4 x M5 bolts for single luminaires
MOUNTING BRACKET MATERIAL:
Aluminium
APPLICATION:
Low vibration
Double Luminaire
Triple Luminaire
MINIMUM RECOMMENDED FASTENERS PER LUMINAIRE:
4 x M12 bolts for double and triple luminaires
MOUNTING BRACKET MATERIAL:
Stainless Steel 304
APPLICATION:
Low vibration
AIMING SINGLE LUMINAIRE
STEP 1
Loosen Screws A and B counter clockwise to allow for rotation of the luminaire.
STEP 2
Rotate the luminaire to your desired angle.
STEP 3
Tighten Screws A and B clockwise to lock into position (9Nm).
- Screw A
- Screw B
AIMING DOUBLE LUMINAIRE
STEP 1
Loosen the angular adjustment M8 screws.
- Angular Adjustment M8 Screw
STEP 2
Once luminaire is aimed, tighten to 7Nm. The bracket allows for 90° vertical rotation and 45° forwards rotation.
AIMING TRIPLE LUMINAIRE
STEP 1
Loosen the angular adjustment M8 screws to adjust angle of the triple luminaire array.
- Angular Adjustment M8 Screw
STEP 2
Once luminaire is aimed, tighten to 7Nm. The bracket allows for 90° vertical rotation and 30° forwards rotation.
STEP 3
This bracket also allows for individual angle adjust of each luminaire. Loosen each angular adjustment M8 screws.
- Angular Adjustment M8 Screw
STEP 4
Once luminaire is aimed, tighten to 7Nm. The bracket allows for 10° positive and negative rotation.
LUMINAIRE SAFETY LANYARD PROVISIONS
Utilize provisioned apertures if safety lanyards are required in the installation.
For maximum safety, utilize a safety lanyard for each provision including single fixtures within the double and triple arrays.
Single Luminaire
Double Luminaire
Utilize safety lanyard provisions for the bracket.
Triple Luminaire
Utilize safety lanyard provisions for the bracket.