COOLON ARIA X RGBW Light Instruction Manual

June 13, 2024
COOLON

ARIA X

INSTALL ATION
INSTRUCTIONS

COOLON ARIA X RGBW Light - 1


INCLUDED

Box Contents

  • Luminaire
  • Mounting Brackets (Integral)

+ Run Box

  • Allen Key
  • Cable Plastic Caps
  • Cable Kits
CONTENTS LxWxH DIMENSIONS
Single Luminaire 582 x 191 x 121mm
Double Luminaire 637 x 249 x 151mm
Triple Luminaire 665 x 292 x 162.5mm
Run Box Varies depending on quantity
ATTENTION
  • Please observe / follow the instructions methodically.
  • Please ensure the units are handled with extreme care.
  • Do not remove product from packaging prematurely. Only remove from packaging when ready for installation.
  • Failure to observe installation instructions and handling will void warranty of the product.
  • Fittings must be installed by a licensed electrician.
  • Before installing, make sure the power supply is switched off or mains cable is disconnected.
  • Aria is designed for a wide range of applications, including those with low vibrations such as bridges and fixed metal structures. However, is not designed for heavy-duty environments with excessive vibration.

INSTALLATION LIMITS @ 230VAC

Maximum 40 x Single Luminaires per individual run.

COOLON ARIA X RGBW Light - b1

INSTALLATION LIMITS @ 120VAC

Maximum 20 x Single Luminaires per individual run.

COOLON ARIA X RGBW Light - b2

2mm distance between the ends of fittings to keep consistent LED pitch.
COOLON ARIA X RGBW Light - b3

  INSTALLATION LIMITS @ 230VAC

Maximum 20 x Double Luminaires fittings per individual run.

COOLON ARIA X RGBW Light - b4

INSTALLATION LIMITS @ 120VAC

Maximum 10 x Double Luminaires per individual run.

COOLON ARIA X RGBW Light - b5

  INSTALLATION LIMITS @ 230VAC

Maximum 13 x Triple Luminaires per individual run.

COOLON ARIA X RGBW Light - b6

INSTALLATION LIMITS @ 120VAC

Maximum 6 x Triple Luminaires per individual run.

COOLON ARIA X RGBW Light - b7

WIRING CONFIGURATION

COOLON ARIA X RGBW Light - c1

  1. EXTENSION DATA 5,000mm

  2. EXTENSION & LEADER KIT
    • CBLKIT-MADA-L-5M

  3. EXTENSION MAINS 5,000mm

  4. LEADER DATA 250mm

  5. LEADER MAINS 400mm

  6. EXTENSION KIT
    • CBLKIT-MADA-J-0.6M (600mm)
    • CBLKIT-MADA-J-5M (5,000mm)
    • CBLKIT-MADA-J-CST (Custom Length)

  7. END-END INTEGRAL JUMPER
    • Integral to 06 lengths only

  8. CAP
    • CBLKIT-MADA-CAPS

DATA Pinouts

  1. DATA F
    OUTPUT

  2. DATA M
    INPUT

  3. DMX +
    Green / White

  4. DMX –
    Green

  5. COMMON
    Grey

MAINS Pinouts

COOLON ARIA X RGBW Light - c3

  1. POWER F
    OUTPUT

  2. POWER M
    INPUT

  3. ACTIVE
    Black

  4. NEUTRAL
    White

  5. EARTH
    Green

COOLON ARIA X RGBW Light - 2

WIRING DIAGRAMS

DALI INSTALLATION

COOLON ARIA X RGBW Light - d1a

  1. DALI
  2. MAINS LEADER
  3. EXTENSION

¹ Control limits defined by the DALI system


0-10V INSTALLATION

COOLON ARIA X RGBW Light - d2

COOLON ARIA X RGBW Light - d3

  1. 0 – 10V
  2. MAINS LEADER

¹ Single luminaire control


CASAMBI INSTALLATION

COOLON ARIA X RGBW Light - d4

  1. CBU-A2D
  2. OTHER CASAMBI DEVICES
  3. DMX LEADER
  4. MAINS LEADER
  5. EXTENSION

¹ Please refer to Casambi’s documentation about system limits and range
² Please refer to CBU-A2D documentation for reference
³ Control limits defined by the DALI system

  1. Termination Caps
CONNECTION

Before installation begins, please ensure that you understand the fitting layout as per luminaire schedule.

COOLON ARIA X RGBW Light - e3 COOLON ARIA X RGBW
Light - e4
CLICK!

COOLON ARIA X RGBW Light - 3

DIMENSIONS

Single Luminaire

  1. 150mm minimum clearance required for full rotation
  2. 200mm minimum clearance required for full rotation

Double Luminaire

  1. 220mm minimum clearance required for full rotation
  2. 200mm minimum clearance required for full rotation

Triple Luminaire

  1. 315mm minimum clearance required for full rotation
  2. 300mm minimum clearance required for full rotation

COOLON ARIA X RGBW Light - 4

DIMENSIONS WITH GLARE SHIELD

Single Luminaire

COOLON ARIA X RGBW Light - f10 COOLON ARIA X RGBW
Light - f12

  1. 176mm minimum clearance required for full rotation
  2. 220mm minimum clearance required for full rotation

Double Luminaire

  1. 220mm minimum clearance required for full rotation
  2. 200mm minimum clearance required for full rotation

Triple Luminaire

COOLON ARIA X RGBW Light - f16

  1. 315mm minimum clearance required for full rotation
  2. 300mm minimum clearance required for full rotation

COOLON ARIA X RGBW Light - 5

MOUNTING FOOTPRINTS

Single Luminaire

COOLON ARIA X RGBW Light - g1

MINIMUM RECOMMENDED FASTENERS PER LUMINAIRE:
4 x M5 bolts for single luminaires

MOUNTING BRACKET MATERIAL:
Aluminium

APPLICATION:
Low vibration

Double Luminaire

COOLON ARIA X RGBW Light - g2

Triple Luminaire

COOLON ARIA X RGBW Light - g3

MINIMUM RECOMMENDED FASTENERS PER LUMINAIRE:
4 x M12 bolts for double and triple luminaires

MOUNTING BRACKET MATERIAL:
Stainless Steel 304

APPLICATION:
Low vibration

AIMING SINGLE LUMINAIRE

STEP 1

Loosen Screws A and B counter clockwise to allow for rotation of the luminaire.

STEP 2

Rotate the luminaire to your desired angle.

COOLON ARIA X RGBW Light - h2

STEP 3

Tighten Screws A and B clockwise to lock into position (9Nm).

COOLON ARIA X RGBW Light - h4

  1. Screw A
  2. Screw B
AIMING DOUBLE LUMINAIRE

STEP 1

Loosen the angular adjustment M8 screws.

  1. Angular Adjustment M8 Screw

STEP 2

Once luminaire is aimed, tighten to 7Nm. The bracket allows for 90° vertical rotation and 45° forwards rotation.


AIMING TRIPLE LUMINAIRE

STEP 1

Loosen the angular adjustment M8 screws to adjust angle of the triple luminaire array.

  1. Angular Adjustment M8 Screw

STEP 2

Once luminaire is aimed, tighten to 7Nm. The bracket allows for 90° vertical rotation and 30° forwards rotation.

STEP 3

This bracket also allows for individual angle adjust of each luminaire. Loosen each angular adjustment M8 screws.

  1. Angular Adjustment M8 Screw

STEP 4

Once luminaire is aimed, tighten to 7Nm. The bracket allows for 10° positive and negative rotation.

LUMINAIRE SAFETY LANYARD PROVISIONS

Utilize provisioned apertures if safety lanyards are required in the installation.

For maximum safety, utilize a safety lanyard for each provision including single fixtures within the double and triple arrays.

Single Luminaire

Double Luminaire

Utilize safety lanyard provisions for the bracket.

COOLON ARIA X RGBW Light - h12

Triple Luminaire

Utilize safety lanyard provisions for the bracket.

COOLON ARIA X RGBW Light - h13

COOLON ARIA X RGBW Light - h14


archsales@coolon.com.au    aus. 1300 287 533 intl. +613 8681 3633   www.coolon.com.au
All documentation is subject to change without notice. Refer to our website for the latest information.

Version 1.0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals