COOLON Ex Dlk Industrial Led User Manual

June 12, 2024
COOLON

COOLON Ex Dlk Industrial Led User Manual
COOLON Ex Dlk Industrial

Product Dimensions Instruction

Product Dimension
IECEx ExTC 23.0006X Ex tb IIIC T65°C Db
CONDITION OF USE: The equipment may be operated in an ambient temperature range of -20°C to 50°C.
Product Dimension
WARNING:
Do not open any covers or optics. Factory sealed – no user serviceable parts inside. Potential electrostatic charging hazard – see cleaning instructions below.

CLEANING INSTRUCTIONS

n order to ensure safe light levels are maintained during operation the optical face of the luminaire should be cleaned at regular intervals. The optical covers are made from polycarbonate.

  •  Use lukewarm soapy water and a soft sponge or cloth to clean the optical surface.
    If luminaires are not accessible by hand use a long-poled car or RV washing pad.

  • If using soapy water rinse using clean water.

  • After final rinse dry off with a soft cloth. Polycarbonate is vulnerable to scratching.

  • Do not scrub with brushes, abrasive materials or sharp instruments as these will mark the surface.

  • Never use solvents, alkaline cleaners, thinners or abrasive cleaners.

  • Do not steam clean or high pressure wash.

  • Never use: acetone, petrol, benzene, or solvents containing Butyl Cellosolve or Isopropanol.

  • Incorrect cleaning which in any way damages the unit automatically renders void all warranties.

INSTALLATION INSTRUCTIONS

Step : 1
Feed the cable through and slide the DLK onto the spigot
Installation Instruction
Step : 2
Tighten bolts to secure luminaire to the spigot.
Installation Instruction

Step : 3 *Optional U-Bolts
Mount the DLK to spigot by securing U-Bolts with washers and Nylock nuts
Installation Instruction
WIRING :

Mains (100 – 240VAC) Version
WIRING
Cable needs to be terminated in a suitable enclosure such that the outer sheath provides the sealing for the inner sheath and conductors.
This is to eliminate the possibility of any ingress due to the capillary effect created as the unit goes through the warm up and cool down cycles.
Mains
www.coolon.com.au

As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field.
The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals