Product Information
The Signal Lighting System is a commercial and industrial lighting solution designed for various applications. It is equipped with the following technical specifications:
- Supply Voltage: 240VAC mains input
- Power: 40W
- Operating Temperature: Suitable for various operating temperatures
- IP Rating: IP66 (protected against dust and powerful water jets)
- IK Rating: IK09 (resistant to impact up to 10 joules)
Product Usage Instructions
- Step 1: Ensure that the fixed nut is not tightened and the luminaire is factory adjusted. Do not move it.
- Step 2: Lock the two pole mount brackets in position by tightening the four nylock nuts. Measure the distance from the top of the pole and ensure that the angles are parallel. The system must not rotate or slide.
- Step 3: The maximum allowed distance from the pole top to the bottom clamp is approximately 2,600mm. At this position, the distance A/F should be 175mm (maximum allowed by the clamp).
- Step 4: Loosen the indicated nuts enough to allow rotation of the clamps.
- Step 5: Rotate the light into the desired position. Tighten the nuts after adjustment to complete the installation.
- Step 6: If additional rotation is required, the light tube can also be rotated. Loosen the nuts of the upper clamp and screws on the bottom cup enough to allow rotation of the light tube.
- Step 7: Rotate the light into the desired position. Tighten the screws on the bottom cup first, then tighten the nuts of the upper clamp until they meet the stoppers to complete the installation.
- Step 8: Wire the lights and power supply into the junction box. Repeat this step for each junction box. Use loom and cable tie as required.
- Step 9: Wire the mains input and luminaire out cables into the power supply.
Important Note: The product must be installed by a suitably qualified person. For more information and updates, please visit our website at www.coolon.com.au.
Technical Specifications
Technical Specifications (per Luminaire)
- SUPPLY VOLTAGE 48VDC ± 10%
- POWER 40W
- OPERATING TEMP. 0°C Tamb 50°C
- IP RATING IP66
- IK RATING IK09
INSTALLATION INSTRUCTIONS
-
Step 1
Tighten the 4x nuts to secure the threaded rods to the pole-clamp sub- assembly. Ensure inner distance between rods are:- TOP CLAMP: 163mm
- BOTTOM CLAMP: 163mm
-
Step 2
Fully Lock the 2 pole mount brackets in position by tightening the 4x nylock nuts. Measure distance from the top of the pole. Ensure the angles are parrallel. The system must not rotate or slide.- Light Adjustment
Angle of the fittings are factory adjusted to achieve 360° of coverage. Do not move unless required. See below for adjustment instructions.
- Light Adjustment
-
Step 4
Loosen indicated nuts enough to allow rotation of the clamps. -
Step 5
Rotate light into desired position. Tighten nuts after adjustment to complete installation. -
Step 6
If additional rotation is required, the light tube can also be rotated. Loosen the nuts of the upper clamp and screws on the bottom cup enough to allow rotation of the light tube. -
Step 7
Rotate light into desired position. Tighten screws on bottom cup first then, tighten nuts of the upper clamp until it meets the stoppers to complete installation. -
Step 8
Wire the lights and power supply into the junction box. Repeat for each junction box. Loom and cable tie as required. -
Step 9
Wire mains input and luminaire out cables into the power supply.
IMPORTANT
Primary use: commercial and industrial applications.
- Read through this manual before installation
- Handle the product with care
- Class I products must be grounded
- The product must be installed by a suitably qualified person
- Do not stare at operating lamp, may be harmful to the eyes
- Turn OFF the power before installation and maintenance
- Make sure the product is securely installed
- The housing might become hot after operation
- Keep optical face clean
CONTACT
- support@coolon.com.au.
- aus. 1300 287 533
- intl. +613 8681 3633
- www.coolon.com.au.
- www.coolon.com.au.
As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field. The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>