Warmup 6iE Smart WiFi Programmable Underfloor Heating Thermostat Instruction Manual

June 5, 2024
Warmup

Warmup 6iE Smart WiFi Programmable Underfloor Heating Thermostat

Instruction

Welcome to the 6iE. The 6iE is a Wi-Fi-enabled thermostat designed to provide timed regulation of electric underfloor heating systems.

The 6iE must be installed by a qualified electrician. It requires a permanent 110V-240V AC, 60Hz supply. The 6iE contains a Class A GFCI with a 5mA trip level and the wiring must conform to the local electrical code. Isolate the 6iE from the main supply throughout the installation process. Conduits are only required where it is mandated by state or provincial code. Please refer to the local electrical code for compliant applications. The 6iE and its packaging are not toys; do not allow children to play with them. Small components and packaging present a risk of choking or suffocation. The 6iE is suitable for indoor use only. It must not be exposed to moisture, vibrations, mechanical loads, or temperatures outside of its rated values. For safety and licensing reasons, unauthorized change and/or modification of the 6iE is not permitted. Ensure the distance from your router to the 6iE is not excessive. This will ensure the wireless connection is not subject to the range or interference issues once installed Install the 6iE in an area with good ventilation. It should not be beside a window/door, in direct sunlight, or above another heat-generating device (e.g. radiator or TV).

  • Isolate the 6iE and supply from the mains supply.
  • Unclip the display from the power base and remove the display
  • DO NOT install the 6iE near a window/door, in direct sunlight, or above another heat-generating device (e.g. radiator or TV).
  • Ensure the distance from the router to 6iE is not excessive to reduce range or interference issues.
  • Install a 3-1/2” (89 mm) deep single gang or 2-gang box with a mud ring in your preferred thermostat location. Pull wires (heater, supply, and sensor) through the gang box and complete terminal wiring. Insert fixing screws through mounting holes of the power base and tighten.
  • The 6iE must be installed by a qualified electrician in accordance with National Electrical Code.

WIRING CONNECTIONS

  • LOAD L1 & L2 Heater Load Max.15A
  • (1800W/120V, 3600W/240V)
  • LINE L1 Supply Live (120 V)
  • LINE L2 Supply Neutral (120 V) /
  • Supply Live (240 V)
  • P1 & PC Probe 1 – Floor/Air Control Sensor
  • (No Polarity)
  • P2 & PC Probe 2 – Limit Sensor (No Polarity)
  • The function of Probe 1, Probe 2 from Control/Limit Sensor can be swapped in Advanced Settings; Sensors & Application.
  • Re-attach the display to the power base and switch on the 6iE. Follow the on-screen instructions to set up the system. Once set up a QR Code will appear.
  • Download the MyHeating App.
  • Open the MyHeating App and scan the QR Code on the 6iE screen and follow the instructions in the App to complete the setup.
  • Scan the QR Code for the full online user guide.

Technical Specifications

Warmup 6iE Smart WiFi Programmable Underfloor Heating
ThermostatFig2

Guarantee

Warmup plc warrants this product, to be free from defects in the workmanship or materials, under normal use and service, for a period of twelve (12) years from the date of purchase by the consumer when installed with a Warmup heater. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either; Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or Contact Warmup. Warmup will determine whether the product should be returned or replaced. The twelve (12) year warranty only applies if the product is registered with Warmup within 30 days after purchase. Registration can be completed online at www.warmup.com This warranty does not cover removal or re- installation costs and shall not apply if it is shown by Warmup that the defect or malfunction was caused by failure to follow the instruction manuals, incorrect installation or damage which occurred while the product was in the possession of a consumer. Warmup’s sole responsibility shall be to repair or replace the product within the terms stated above. If the 6iE is installed with a non-Warmup heater a three (3) year warranty will apply. This warranty does not extend to any associated software such as apps or portals. WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY WARMUP MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE TWELVE-YEAR DURATION OF THIS WARRANTY. This Warranty does not affect your statutory rights.

Important Notices

FCC Notice

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • this device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.
  • Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio TV technician for help.

Caution

To maintain compliance with the RF exposure guidelines, place the unit at least 8″ (20 cm) from nearby person

IC Statement

This device complies with Industry Canada Licenceexempt RSS-247. Operation is subject to the following two conditions

  • This device may not cause interference, and
  • This device must accept any interference, including interference that may cause undesired operation of the device.
  • To maintain compliance with the RF exposure guidelines, place the unit at least 8″ (20 cm) from nearby persons.

GFCI Notice

The GFCI feature is used to detect any leakage of current from your heating system. During a ground fault, the two lines of the load will be cut off. Once your thermostat is installed and connected to a power supply you can test the GFCI function by increasing the set temperature until heating is on – the heat up icon ( ) will be illuminated – and pressing the “TEST” button. If your test is successful you will see the red GROUND FAULT screen and you will need to hold the screen for 3 seconds in order to restore the heating operation. In the following circumstances, you should immediately isolate the power supply to the thermostat and contact our helpline: If the thermostat detects that one of the relays has FAILED to open correctly you will see the DEVICE ERROR screen. If the red GROUND FAULT page does not appear having pressed the test button. NOTE: The GFCI test should be carried out monthly.