COOLON DLK Industrial LED User Manual

June 12, 2024
COOLON

COOLON DLK Industrial LED

Product Information

Product Name DLK INDUSTRIAL LED
Manual Edition 0.8
Dimensions 370mm x 402mm x 130mm
Power (Mains Powered) 69W @ 230VAC
Power (Low Voltage) 62W @ 24VDC
IP/IK Rating IP66 / IK09

Product Usage Instructions

  1. Step 1: Feed the cable through and slide the DLK onto the spigot.
  2. Step 2: Tighten bolts to secure luminaire to the spigot.
  3. Step 3 (Optional): Mount the DLK to spigot by securing U-Bolts with washers and Nylock nuts.

Product Wiring Instructions

Version ACTIVE NEUTRAL EARTH + POSITIVE (24VDC) – NEGATIVE (24VDC)
Mains (230VAC) Red Black Green/Yellow N/A N/A
Low Voltage (24VDC) N/A N/A N/A White Black

Light Sensor Dimming

The DLK LED will be at 100% brightness when it is turned on and then will dim to 4% brightness when daylight is detected. After 3 minutes of the daylight dropping below the minimum ambient light threshold, the DLK LED will ramp up to 100% brightness. (Only applies to DLK equipped with light sensor)

IMPORTANT: Primary use of this product is for commercial and industrial applications.

For more information and updates, please visit our website: www.coolon.com.au

Note: Product must be installed by a suitably qualified person. All documentation is subject to change without notice.

DIMENSIONS

Technical Specifications

  • MP: Mains Powered
  • Voltage In: 100 – 240VAC 50/60Hz
  • Power: 69W @ 230VAC
  • IP/IK Rating: IP66 / IK09
  • Operating Temp.°: -20°C Tamb 50°C

ELV: Extra Low Voltage Luminaire

  • Voltage In: 22.5 – 26VDC
  • Power: 62W @ 24VDC
  • IP/IK Rating: IP66 / IK09
  • Operating Temp.°: -20°C Tamb 50°C

INSTALLATION INSTRUCTIONS

Step 1

  • Feed the cable through and slide the DLK onto the spigot.

Step 2

  • Tighten bolts to secure luminaire to the spigot.

*Step 3 Optional U-Bolts**

  • Mount the DLK to spigot by securing U-Bolts with washers and Nylock nuts.

WIRING

Mains (230VAC) Version

Low Voltage (24VDC) Version

LIGHT SENSOR DIMMING

The DLK LED will be at 100% brightness when it is turned on and then will dim to 4% brightness when daylight is detected. 3 minutes after the daylight has dropped below the minimum ambient light threshold, the DLK LED will ramp up to 100% brightness. (Only applies to DLK equipped with light sensor)

IMPORTANT

Primary use: commercial and industrial applications.

  • Read through this manual before installation
  • Handle the product with care
  • Class I products must be grounded
  • The product must be installed by a suitably qualified person
  • Do not stare at operating lamp, may be harmful to the eyes
  • Turn OFF the power before installation and maintenance
  • Make sure the product is securely installed
  • The housing might become hot after operation
  • Keep optical face clean

support@coolon.com.au • aus. 1300 287 533 • intl. +613 8681 3633 • www.coolon.com.au  As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field. The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information. Product must be installed by a suitably qualified person. All documentation is subject to change without notice. www.coolon.com.au.