  • Wide input range 100~305V AC( Class I)
  • Full power output at 70~100% Constant power mode operation
  • Metal case with IP67, suitable for outdoor application
  • Class 2 power unit(except for L type)
  • Surge protection with 6KV/4KV
  • 3 in 1 dimming function (Dim to off and Isolation design)
  • India (EESL) version with Input Over Voltage Protection can survive input voltage stress of 440 Vac for 48 hours
  • Protection functions: OVP/SCP/OCP/OTP
  • Life time >50,000 hrs. and 5 years warranty

Applications

  • Skyscraper lighting
  • Street lighting
  • Floodlight Lighting
  • Stage lighting
  • Fishing lighting
  • Horticulture lighting
  • Bay lighting
  • DMX power supply
  • Type HL for use in class I, Division 2

Description

XLG-75 series is a 75W LED AC/DC driver featuring the constant power mode.XLG-75 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 5000mA. Thanks to the high efficiency up to 91%, with the fanless design, the entire series is able to operate for – 40°C~+90°C case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-75 series comply with the latest version of IEC61347/GB7000.1-2015 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.

Model Encodina

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-1

Note:

  1. 12V and 24V models without the AB type
  2. India version needs MOQ for production, please consult MEANWELL for detail

SPECIFICATION

MODEL XLG-75 -12- XLG-75 -24-






OUTPUT

| DC VOLTAGE| 12V| 24V
CONSTANT CURRENT REGION Note.2| 8.4~ 12V| 16.8~ 24V
RATED CURRENT| 5A| 3.1A
RATED POWER| 60W| 74.4W
RIPPLE & NOISE (max.) **Note.3| 150mVp-p| 240mVp-p
CURRENT ADJ RANGE| 2.5A~5A| 1.55A~3.1A
VOLTAGE TOLERANCE Note.4| ±3.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%
LOAD REGULATION| ±2%| ±1%
SETUP, RISE TIME Note.6| 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
HOLD UP TIME (Typ.)**| 10ms/ 230VAC 10ms/ 115VAC






INPUT

| VOLTAGE RANGE Note.5| 100 ~ 305VAC           142 ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” section)

FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
TOTAL HARMONIC DISTORTION| THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
EFFICIENCY (Typ.)| 89%| 90%
AC CURRENT| 1.0A / 115VAC 0.45A / 230VAC 0.38A/277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=300 μ s measured at 50% Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 9 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO           LOAD POWER CONSUMPTION| No load power consumption <0.5W(for standard version)




PROTECTION

| OVER CURRENT| 95 ~ 108%
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 13 ~ 19V| 26 ~ 36V
Shut down output voltage, re-power on to recover
INPUT OVER VOLTAGE Note.7| 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max
OVER TEMPERATURE| Shut down output voltage, re-power on to recover




ENVIRONMENT

| WORKING TEMP.| Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +90℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes










EMC SAFETY &

| SAFETY STANDARDS Note.7| UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12;ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB19510.1,GB19510.14; EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)

(for XLG-75I type only); OM-058-SCFI-2017(except for Blank type);IP67 approved

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH



EMC EMISSION

| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Harmonic Current| BS EN/EN61000-3-2 ,GB/T17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–





EMC IMMUNITY

| BS EN/EN61547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT/Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods


OTHERS

| MTBF| 1232.28K hrs min. Telcordia SR-332 (Bellcore) ; 376.3Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1406332mm (LWH)
PACKING| 0.58Kg;24pcs /15Kg /0.85CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2. Please refer to “DRIVING METHODS OF LED MODULE”.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7. Input over voltage only for XLG-75 I series ,and I series without UL/CSA certificate.

8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.

10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

12. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.

13. To fullfill requirements of the latest ErP regulation for lighting fixtures, this LED drivers can only be used behind a switch without permanently connected   to the mains

14. For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)

15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.

※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx) Fil e __Name:XLG-75-SPE C 2021-11-26

MODEL XLG-75 -L- XLG-75 -H-




OUTPUT

| RATED CURRENT| 700mA| 1400mA
RATED POWER| 74.9W| 75.6W
CONSTANT CURRENT REGION| 53 ~ 107V| 27 ~ 56V
FULL POWER CURRENT RANGE| 700~1050mA| 1300~2100mA
OPEN CIRCUIT VOLTAGE (max.)| 115V| 60V
CURRENT ADJ. RANGE| 350~1050mA| 650~2100mA
CURRENT RIPPLE| 3.0%(@rated current)
CURRENT TOLERANCE| ±5%
SET UP TIME| 500ms/230VAC, 1200ms/115VAC








INPUT

| VOLTAGE RANGE| ****

Note.5

| 100 ~ 305VAC           142VDC ~ 431VDC

(Please refer to “STATIC CHARACTERISTIC” ang “ DRIVING METHODS OF LED MODULE”section)

FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 / 277VAC at full load

(Please refer to “Power Factor Characteristic” section)

TOTAL HARMONIC DISTORTION| THD< 10% (@ load≧50% at 115VAC/230VAC ,@load≧75% at 277VAC) Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
EFFICIENCY (Typ.)| 91%| 90%
AC CURRENT (Typ.)| 1A / 115VAC           0.45A / 230VAC           0.38A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=300 μ s measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| 9 unit(circuit breaker of type B) / 14 units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY

POWER CONSUMPTION

| Standby power consumption <0.5W for AB-Type(Dimming OFF)(for standard version)



PROTECTION

| OVER POWER| 110 ~ 150%
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
INPUT OVER VOLTAGE Note.7| 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours @ tc 75℃ max
OVER TEMPERATURE| Shut down output voltage, re-power on to recovery



ENVIRONMENT

| WORKING TEMP.| Tcase=-40 ~ +90℃(Please refer to “OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes




SAFETY & EMC

| SAFETY STANDARDS Note.7| UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;

GB19510.1,GB19510.14; EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)

(for XLG-75I type only); NOM-058-SCFI-2017(except for Blank type);IP67 approved

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH



EMC EMISSION

| Parameter| Standard| Test Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T17743| —–
Harmonic Current| BS EN/EN61000-3-2 ,GB/T17625.1| Class C @load≥50%
Voltage Flicker| BS EN/EN61000-3-3| —–





EMC IMMUNITY

| BS EN/EN61547
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 3
EFT/Burst| BS EN/EN61000-4-4| Level 3
Surge| BS EN/EN61000-4-5| 4KV/Line-Line 6KV/Line-Earth
Conducted| BS EN/EN61000-4-6| Level 3
Magnetic Field| BS EN/EN61000-4-8| Level 4
Voltage Dips and Interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods,

95% interruptions 250 periods


OTHERS

| MTBF| 1232.28K hrs min.| Telcordia SR-332 (Bellcore) ; 376.3Khrs min.| MIL-HDBK-217F (25℃)
DIMENSION| 1406332mm (LWH)
PACKING| 0.58Kg;24pcs /15Kg /0.85CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.

2. Please refer to “DRIVING METHODS OF LED MODULE”.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.

6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.

7. Input over voltage only for XLG-75 I series ,and I series without UL/CSA certificate.

8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly  tc point (or TMP, per DLC), is about 75℃ or less.

10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com

11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

12. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.

13. To fullfill requirements of the latest ErP regulation for lighting fixtures, this LED drivers can only be used behind a switch without permanently connected  to the mains

14. For any application note and IP water proof function installation caution, please refer our user manual before using. https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)

15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.

※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx) Fil e __Name:XLG-75-SPE C 2021-11-26

BLOCK DIAGRAM

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-2

DRIVING METHODS OF LED MODULE

  • I-V Operating Area

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-3

  • This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-4

DIMMING OPERATION

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-5

3 in 1 dimming function (for AB-Type)

  • Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
  • Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
  • Dimming source current from power supply: 100μA (typ.)

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-6 MEAN-WELL-XLG-75
-Series-75W-Constant-Power-Mode-LED-Driver-fig-7 MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-
Driver-fig-8

Note :

  1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
  2. The output current could drop down to 0% when dimming input is about 0Ω or 0Vdc, or 10V PWM signal with 0% duty cycle.

OUTPUT LOAD vs TEMPERATURE

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-9

If XLG-75 operates in Constant Current mode with the rated current the maximum workable Ta is 60℃ (Typ. 230VAC) or 50℃(Typ.100VAC) Below 110VAC@ -30℃ may retry to 2nd setup

STATIC CHARACTERISTIC

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-10

POWER FACTOR (PF) CHARACTERISTIC

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-11

TOTAL HARMONIC DISTORTION (THD)

  • XLG-75-L Model, Tcase at 75℃

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-12

EFFICIENCY vs LOAD

XLG-75 series possess superior working efficiency that up to 92% can be reached in field applications.

  • XLG-75-L Model, Tcase at 75℃MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-fig-13

LIFE TIME

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-14

MECHANICAL SPECIFICATION

Blank-Type

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-15

A-Type

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-16

AB-Type

MEAN-WELL-XLG-75-Series-75W-Constant-Power-Mode-LED-Driver-
fig-17

INSTALLATION MANUAL

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals