MEAN WELL ELG-75 Series 48-75W Constant Voltage Constant Current LED
Driver
Features
- Constant Voltage + Constant Current mode output
- Metal housing design with functional Ground
- Built-in active PFC function
- Class 2 power unit
- No load / Standby power consumption <0.5W
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off); Smart timer dimming; DALI
- Typical lifetime>50000 hours
- 5 years warranty
Description
ELG-75 series is a 75W AC/DC LED driver featuring the dual mode constant voltage and constant current output. ELG-75 operates from 100~305VAC and offers models with different rated voltage ranging between 12V and 48V. Thanks to the high efficiency up to 90%, with the fanless design, the entire series is able to operate for -40°C ~ +85°C case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. ELG-75 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Applications
- LED street lighting
- LED architectural lighting
- LED bay lighting
- LED floodlighting
- Type “HL” for use in Class I, Division 2 hazardous (Classified) location.
Model Encoding
Type | IP Level | Function | Note |
---|---|---|---|
Blank | IP67 | Io and Vo fixed. | In Stock |
A | IP65 | Io and Vo adjustable through built-in potentiometer. | In Stock |
B | IP67 | 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) | In |
Stock
AB| IP65| Io and Vo adjustable through built-in potentiometer &
3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance)
| In Stock
DA| IP67| DALI control technology.| In Stock
Dx| IP67| Built-in Smart timer dimming function by user re uest.| By re uest
D2| IP67| Built-in Smart timer dimming and programmable function.| In Stock
SPECIFICATION
MODEL| | ELG-75-12| ELG-75-24| ELG-75-36|
ELG-75-42| ELG-75-48
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V| 36V| 42V| 48V
CONSTANT CURRENT REGION Note.2| 6 ~ 12V| 12 ~ 24V| 18 ~ 36V|
21 ~ 42V| 24 ~ 48V
RATED CURRENT| 5A| 3.15A| 2.1A| 1.8A| 1.6A
RATED POWER **Note.5**
| 200VAC ~ 305VAC
60W| 75.6W| 75.6W| 75.6W| 76.8W
100VAC ~ 180VAC
48W| 60W| 60W| 60W| 60W
RIPPLE & NOISE (max.) **Note.3**| 150mVp-p| 200mVp-p| 250mVp-p|
250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE
| Adjustable for A/AB-Type only (via built-in potentiometer)
10.8 ~ 13.2V| 21.6 ~ 26.4V| 32.4 ~ 39.6V| 37.8 ~ 46.2V| 43.2 ~ 52.8V
CURRENT ADJ. RANGE
| Adjustable for A/AB-Type only (via built-in potentiometer)
2.5 ~ 5A| 1.57 ~ 3.15A| 1.05 ~ 2.1A| 0.9 ~ 1.8A| 0.8 ~ 1.6A
VOLTAGE TOLERANCE Note.4| ±3.0%| ±3.0%| ±2.5%| ±2.5%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.6| 500ms, 100ms/115VAC, 230VAC
HOLD UP TIME (Typ.)| 10ms/ 230VAC 10ms/ 115VAC(at full load)
INPUT
| ****
VOLTAGE RANGE **Note.5**
| 100 ~ 305VAC 142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR
| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION
| THD< 20%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 86%| 88%| 89%| 90%| 90%
AC CURRENT| 0.7A / 115VAC 0.45A / 230VAC 0.38A/277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=350 μ s measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| ****
5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
NO LOAD / STANDBY POWER CONSUMPTION| No load power consumption <0.5W for
Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type
PROTECTION
| ****
OVER CURRENT
| 95 ~ 108%
Constant current limiting, recovers automatically after fault condition is
removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition
is removed
OVER VOLTAGE
| 14 ~ 18V| 28 ~ 34V| 41 ~ 48V| 47 ~ 54V| 54 ~ 62V
Shut down output voltage, re-power on to recover
OVER TEMPERATURE| Shut down output voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| Tcase=-40 ~ +85℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC
| ****
SAFETY STANDARDS
| UL8750(type”HL”), CSA C22.2 No. 250.13-12; IEC/BS EN/EN/AS/NZS 61347-1,
IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384;EAC TP TC 004;BIS
IS15885(for 12A/12DA/12B/24A/24B/24DA/36A/36B/42A/42B/48A/48B only); IP65 or
IP67; GB19510.1, GB19510.14; KC61347-1,KC61347-2-13 approved
DALI STANDARDS| Compliance to IEC62386-101,102,(207 by request) for DA
Type only
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION| Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C
(@load≧50%) ; BS EN/EN61000-3-3; GB17743, GB17625.1; EAC TP TC 020; KC
KN15,KN61547
EMC IMMUNITY
| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV);EAC TP TC 020; KC KN15,KN61547
OTHERS
| MTBF| 1172K hrs min. Telcordia SR-332 (Bellcore) 331Khrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 1806335.5mm (LWH)
PACKING| 0.8Kg;16pcs/13.4Kg/0.67CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated current and 25℃ of ambient temperature.
2. Please refer to “DRIVING METHODS OF LED MODULE”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final e uipment. Since EMC performance will be affected by the complete installation, the final e uipment manufacturers must re- ualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
9. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 11.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
※ Product Liability Disclaimer: For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
DRIVING METHODS OF LED MODULE
- This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
DIMMING OPERATION
- DIM+ for B/AB-Type DA+ for DA-Type PROG+ for D2-Type
- DIM- for B/AB-Type DA- for DA-Type PROG- for D2-Type
3 in 1 dimming function (for B/AB-Type)
- Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
- Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.
- Dimming source current from power supply: 100μA (typ.)
Applying additive 0 ~ 10VDC
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
Applying additive resistance:
Note:
- Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.
- The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.
- DALI Interface (primary side; for DA-Type)
- Apply DALI signal between DA+ and DA-.
- DALI protocol comprises 16 groups and 64 addresses.
- First step is fixed at 8% of output.
- Smart timer dimming function (for Dxx-Type by User definition)
MEAN WELL Smart timer dimming primarily provides the adaptive proportion dimming profile for the output constant current level to perform up to 14 consecutive hours. 3 dimming profiles hereunder are defined accounting for the most frequently seen applications. If other options may be needed, please contact MEAN WELL for details.
Ex : ◎D01-Type: the profile recommended for residential lighting
TIME matches the Operating Time in the diagram whereas LEVEL matches the Dimming Level.
Example:
If a residential lighting application adopts D01-Type when turning on the
power supply at 6:00 pm, for instance:
- The power supply will switch to the constant current level at 100% starting from 6:00 pm.
- The power supply will switch to the constant current level at 70% in turn, starting from 0:00 am, which is 06:00 after the power supply turns on.
- The power supply will switch to the constant current level at 50% in turn, starting from 1:00 am, which is 07:00 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00 am, which is 11:00 after the power supply turns on.
The constant current level remains till 8:00 am, which is 14:00 after the power supply turns on.
Ex:◎D02-Type: the profile recommended for street lighting
TIME matches Operating Time in the diagram whereas LEVEL matches Dimming Level.
Example:
If a street lighting application adopts D02-Type, when turning on the power
supply at 5:00pm, for instance:
- The power supply will switch to the constant current level at 50% starting from 5:00pm.
- The power supply will switch to the constant current level at 80% in turn, starting from 6:00pm, which is 01:00 after the power supply turns on.
- The power supply will switch to the constant current level at 100% in turn, starting from 8:00pm, which is 03:00 after the power supply turns on.
- The power supply will switch to the constant current level at 60% in turn, starting from 1:00am, which is 08:00 after the power supply turns on.
- The power supply will switch to the constant current level at 80% in turn, starting from 4:00am, which is 11:00 after the power supply turns on. The constant current level remains till 6:30am, which is 14:00 after the power supply turns on.
Ex:◎D03-Type: the profile recommended for tunnel lighting
TIME matches Operating Time in the diagram whereas LEVEL matches the Dimming Level.
Example:
If a tunnel lighting application adopts D03-Type, when turning on the power
supply at 4:30 pm, for instance:
- The power supply will switch to the constant current level at 70% starting from 4:30 pm.
- The power supply will switch to the constant current level at 100% in turn, starting from 6:00 pm, which is 01:30 after the power supply turns on.
- The power supply will switch to the constant current level at 70% in turn, starting from 5:00 am, which is 11:00 after the power supply turns on.
The constant current level remains till 6:30 am, which is 14:00 after the power supply turns on.
OUTPUT LOAD vs TEMPERATURE
OUTPUT LOAD vs TEMPERATURE(Note.9)
STATIC CHARACTERISTIC
- De-rating is needed under low input voltage.
POWER FACTOR (PF) CHARACTERISTIC
- Tcase at 75℃
Constant Current Mode
TOTAL HARMONIC DISTORTION (THD
- 48V Model, Tcase at 75℃
EFFICIENCY vs LOAD
ELG-75 series possess superior working efficiency that up to 90% can be reached in field applications.
- 48V Model, Tcase at 75℃
LIFE TIME
Mechanical Specification
Blank-Type
- CASE NO.: 243A Unit:mm
A-Type
AB-Type
B/DA/D2-Type
3Y Model (3-wire input)
- Note 1: Please connect the case to PE for the complete EMC deliverance and safety use.
- Note 2: Please contact MEAN WELL for the input wiring option with PE.
Installation Manual
Please refer to: http://www.meanwell.com/manual.html.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>