signify ID-39 TruGroove Recessed Micro T Grid Instruction Manual

June 4, 2024
signify

Linear

TruGroove Recessed Micro
ID-23 T-Grid

Installation Instructions

Standalone or Continuous Run in T-Grid Ceiling
These instructions review how to install TruGroove recessed micro fixtures in T-Grid ceilings. For continuous run lengths, Please refer to layout drawings supplied by Philips Ledalite in conjunction with these installation instructions. The graphics below show the components required to install a run of TruGroove fixtures in T-Grid ceilings.

i Hanger Kit(s)

  • Bracket (x4)
  • Screws (x8)

NOTE: One kit required for each module.

ii Joint Kit(s)

  • Joiner Aligners (x2)
  • Joining Brackets (x2)
  • Hex Bolts (x4)
  •  Screw(s) ( x1 symmetric, x2 for asymmetric )
  • LED pan connectors (x1)

NOTE: Image shown is a symmetric connector. Asymmetric has two pieces.
NOTE: One (1) kit required for each module joint in continuous runs

ID-23 TruGroove Recessed Micro T-Grid Installation Instructions

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Important Notes

Warning, Shock Hazard

Fixture must be connected to the building ground via the provided ground wire before connecting to the mains power supply.
Disconnect or turn off the power before attempting any installation, service, or maintenance.

Prepare Fixtures

Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings. Remove fixtures from boxes.  Remove plastic from fixtures. Match up each fixture and lens based on the spec tag and ID number labeled on each fixture box for the specified run.

  1. T-Grid
    Install main T’s, 2.75” on center. For continuous row lengths, refer to supplied layout drawings. Add 1/4 “ to the overall housing length indicated on your layout drawings. Position the cross T.
    Install Fixtures

  2. Install Mounting Brackets

    Important:
    Install T-Grid mounting brackets to the required height.

  3. Install Fixture Above T-Bar Grid
    Install the first fixture (or Standalone Unit) from above the T-Bar Grid.
    NOTE: For Standalone fixtures skip to step 8

  4. Install Joiner Aligners
    In the joining fixtures install the joiner aligners in the trim extrusion to approximately halfway
    Important: To insert aligners, tap gently with a hammer until half is inserted into the joiner channel. Be sure to engage the dimple.

  5. Complete Wiring and Connect Fixtures
    Install the joiner fixture into the T-Bar Grid from above. Complete wiring and slide the fixtures together.

  6. Open Slots for Joiner Brackets
    Snap off the safety cover on joiner brackets slots with a flathead screwdriver. This only needs to be done on one side that requires joining.

  7. Install Joiner Brackets
    Install supplied side attachment brackets with 3/8” nut driver.

  8. Secure Fixture on the Grid

    Secure the fixture to T-bar the Grid. For continuous runs, finish installing the run first and then secure it to the T-Bar grid.

  9. **Install Power Drop

** Install power drop at the desired location. At the power location(s), remove factory installed wire cover. Feed power wires through. Complete all wiring connections.

  1. Install Wire Access Cover

    Install wire access cover to close the fixture

  2. **Install Seismic Restraints

** Install seismic restraints according to local building code requirements.

  1. a LED Pan Joiner – Symmetric
    Mount the LED pan connector with the supplied screw in the joiner kit.
    12b LED Pan Joiner – Asymmetric
    Mount the LED Pan connector with the supplied screw in the joiner kit. There are two pieces for asymmetric fixtures.

  2. Install Snap-In Flush Lens
    Snap-in lens into fixture.

Standalone Units: Lenses are supplied in 2’, 3’, 4’, 5’, 6’, or 8’ lengths.
Continuous Runs: Lenses are pre-cut to a maximum of 8’ lengths and are specific to run lengths. Consult layout drawings for placement.

Sensors in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
    Note:
    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
    Multiple Sensors Controlling Separate Zones in a Row

  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes:
    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
    • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
    Sensor Spacing
    • For correct operation, sensors should be placed a minimum distance of 8ft apart.
    • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB, or RA options):
    DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
    Fixture mains wiring should not be connected to a circuit with an external on/off switch.

  • For best aesthetic condition, place sensors at the ends of the row only so as not to break the continuous lens.

  • For better occupancy coverage in long rows, sensors may be placed mid-run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, a remote sensor may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:
Note: Longer dimension of the detection area (Y1, Y2) is parallel to the longer dimension of the luminaire.

Daylight sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside from entering the sensor (for example sunlight reflection on a car
    hood) as this will lead to incorrect light regulation.

As a guideline, the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.
The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (person moving ≤3ft/s or 0.9m/s).
  • Major movement (person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response

ATTENTION: Install in accordance with local and national building and electric codes.

2021 Signify Holding. All rights reserved. The information provided herein is subject to change. without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify.
Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807 Telephone: 855-486-2216
Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3 Telephone: 800-668-9008
All trademarks are owned by Signify Holding or their respective owners.

6/9/2022  www.ledalite.com
www.signify.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals