MEAN WELL MPS-30 Series 30W Single Output for Medical Type Instruction Manual
- June 4, 2024
- MEAN WELL
Table of Contents
30W Single Output for Medical Type
M P S – 3 0 series
Features
- Universal AC input / Full range
- Low leakage current <200pA
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Medical safety approved (2 x MOPP between primary to secondary)
- Fixed switching frequency at 100KHz
- Low cost
- High reliability
- 3 years warranty
SPECIFICATION
MODEL| MPS-30-5| MPS-30.12| MPS-30-15| MPS-30-24|
MPS-30-27| MPS-30-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 48V
RATED CURRENT| SA| 2.5A| 2A| 1.2A| 1.1A| 0.6A
CURRENT RANGE| 0 – 5A| 0 – 2.5A| 0 – 2A| 0 – 12A| 0-1.1A| 0 – 0.6A
RATED POWER| 25W| 30W| 30W| 28.8W| 29.7W| 282W
RIPPLE & NOISE (ma) Note.2| 80mVp-p| 120mVp-p| 150mVp-p| 240mVp-p| 240mVp-p|
240mVp-p
VOLTAGE TOLERANCE Note.3| i 3.0%| r 3.0%| 13.%| 13.%| 13.%| 12.%
LINE REGULATION| 11.%| 11.%| 11.%| 11.%| 11.%| 11.%
LOAD REGULATION| 12.%| -1.%| 11.%| 1.1.0%| 11.%| 11.%
SETUP, RISE TIME| 500ms. 30ms/230VAC SOOms. 30ms/115VAC at ful load
HOLD UP TIME (Typ.)| 70ms/230VAC 12ms/115VAC at full load
INPUT| VOLTAGE RANGE| 88 – 264VAC aub switch 120 – 370VDC
FREQUENCY RANGE| 47 – 63Hz
EFFICIENCY (Typ.)| 72% I 75% 178% 177% I 78% 178%
AC CURRENT (Typ.)| 0.8A1115VAC 0.5A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30N230VAC
LEAKAGE CURRENT| Earth leakage current < 20001264VAC
PROTECTION| OVERLOAD| Above 105% rated output power
Protection type: Hiccup mode. recovers automatically after the fault condition
is removed
OVERVOLTAGE| 5.5 -6.75V 1 132 – 18.2V 1 16.5 -2025V 1 26.4 -32.4V 1 29.7 –
36.45V 1 52.8 – 64.8V
Protect= type : Hiccup mode. recovers automatically after the fault condition
is removed
OVER TEMPERATURE| Shut down of voltage. re-power on to recover
EIMRONNENT| WORKING TEMP.| -10 – •60 C (Refer to ‘berating Curve’)
WORKING HUMIDITY| 20- 90% RH non-condensing
STORAGE TEMP.. HUMIDITY| -20- •85 C.10 – 95% RH
TEMP. COEFFICIENT| ±0.03%1C (0 – 50t)
VIBRATION| 10- 500Hz. 2G 10mindlcycle. period for 60min. each along X. Y.Z
axes
SA TY &FE EMC (Note 4)| SAFETY STANDARDS| ANSI/MMI E560601-1. TUV
EN60601-1.1E080601-1 approved
ISOLATION LEVEL| Primary-Secondary: 2xMOPP. Primary-Earth:1 xMOPP
WITHSTAND VOLTAGE| VP-0/P:IKVAC IIP-FG2KVAC OiP-FG:SHORT
ISOLATION RESISTANCE| 1/P-011s, I/P-FG:100M Ohms / 500VDC / 25C/ 70% RH
EMC EMISSION| Compliance to EN55011 (CISPR11) Class B. EN61000-3.2.-3
EMC IMMUNITY| Compliance to EN61000-4-22.4.5.6.8.11.EN55024.EN60601.1-2.
medical level. criteria A
OTHERS| MTBF| 547Khrs min. ML-HDBK-217F(2512)
DIMENSION| 101.6’65.8’23.5mm (12WIH)
PACKING| 0.16Kg: 90pcs/15.8Kg11.06CUFT
NOTE| I. AI parameters NOT specially mentioned are measured at 230VAC
Mal rated load and 26-c cr ambient temperature.
2 Ripple & noise are measured at 2014H2 of bandwidth by usrg it twisted pa
‘woe terminated with a 0.1u18 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regJabcn.
4. The power supply is considered a component that will be instated into the
final equipment. Al the EKE tests are been executed by mounting the unit on a
36Orrrn*360mm metal plate with Imm of thickness. The foal equipment must be
re-confirmed that it sat meets EMC directives. For guidance on how to perform
these EMC tests. please refer to ‘EMI testing of component power supplies: (as
eyelet: Ile on
herps:/www.menwell.com
5. When the input voltage s Ic6s than 40VAC. the SPS may exhibit degradation
of performance. The final product manufacturers must re-confirm xis deviation
that does not affect basic safety or essential performance. -‘.. Product
Lialolly Osclaimer For detailed information. please refer to
herps:/www.menwell.com/serviceDisclaimer.aspx
Mechanical Specification
Unit:mm
Block Diagram
Derating Curve
Static Characteristics