renkforce RF-5151026 Thermal Transfer Ribbon
Product Information
- Product Name: Ribbon Cartridge for RF-HSP-500
- Color: Black
- Item Number: 2575513
- Intended Use: For automatic thermal transfer printer RF-HSP-500
to label shrink tubes
Product Usage Instructions
Safety Instructions
- If you lack expertise in installation, please have the unit installed by a qualified technician! Improper installation can cause damage to both the ribbon cartridge and your printer. Turn off the printer before installation!
- After printing, the print head may remain hot for some time! Warning, risk of burns!
Installation
-
1. Turn off the printer.
- Open the printer by pushing the locking lever upwards and lifting the printer housing.
- Put the ribbon cartridge into the printer as illustrated:
- Squeeze the clips (b2) on both sides of the cartridge when loading the ribbon.
- After inserting the ribbon, ensure the two clips (b2) are properly engaged.
- After installation, tighten the ribbon by turning the upper roller (b1) by hand in the direction of the arrow.
- Close the housing again.
Disposal
Dispose of the product according to local regulations.
Latest Product Information
Download the latest product information at www.conrad.com/downloads or scan the QR code shown on the package. Follow the instructions on the website.
This is a publication by Conrad Electronic SE,
Klaus-Conrad-Str. 1, D-92240 Hirschau
(www.conrad.com).
Copyright 2022 by Conrad Electronic SE.
Operating instructions
Ribbon cartridge for RF-HSP-500 black
Item no. 2575513
Intended use
This product can be used with the RF-HSP-500 automatic thermal transfer
printer for labelling heat shrink tubes.
Please observe the safety instructions at all times!
- Using this product for any purpose other than those described above may damage the product and result in a short circuit, fire or electric shock. The product must not be modified or reas-sembled!
- This product complies with statutory, national and European regulations. All company and prod-uct names contained herein are trademarks of their respective owners. All rights reserved.
Delivery content
- Ribbon cartridge for RF-HSP-500 “black”
- Operating instructions
Latest product information
Download the latest product information at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.
Explanation of symbols
The following symbols appear on the product/device or in the text:
- This symbol warns of hazards that can lead to injury.
Safety instruction
Read the operating instructions carefully and especially observe the safety information. If you do not follow the safety instructions and information on proper handling, we assume no liability for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
- For safety and licensing reasons, no unauthorised conversion and/or modification of the product is allowed.
- This product is not a toy. Keep it out of the reach of children and pets.
- Do not leave packaging material lying around carelessly, as it could become a dangerous plaything for children.
- The product must not get damp or wet.
- Handle the product with care. Jolts, impacts or a fall even from a low height may damage the product.
- If you have any questions that are not answered in the operating instructions, please con-tact our technical department or third-party specialist.
Installation
If you lack expertise in installation, please have the unit installed by a
quali-fied technician! Improper installation can cause damage to both the
ribbon cartridge and your printer. Turn off the printer before installation!
After printing, the print head may remain hot for some time! Warning, risk of
burns!
- Open the printer by pushing the locking lever upwards and lifting the printer housing.
- Put the ribbon cartridge into the printer as illustrated.
- Squeeze the clips (b2) on both sides of the cartridge when loading the ribbon.
- After inserting the ribbon, ensure the two clips (b2) are properly engaged.
- After installation, tighten the ribbon by turning the upper roller (b1) by hand in the direction of the arrow.
- Close the housing again.
Disposal
Product
This symbol must appear on any electrical and electronic equipment placed
on the EU market. This symbol indicates that this device should not be
disposed of as unsorted municipal waste at the end of its service life. Owners
of WEEE (Waste from Electrical and Electronic Equipment) shall dispose of it
separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection
point. Distributors of electrical and electronic equipment are legally obliged
to provide free take-back of waste. Conrad provides the following return
options free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be
disposed of.
It should be noted that different obligations about the return or recycling of
WEEE may apply in countries outside of Germany.
Technical data
- Colour…………………………………….. black
- Width……………………………………… 55 mm
- Length……………………………………. 45 m
- Operating conditions…………………. 15 °C to +35 °C, 10% to 90% RH, non-condensing
- Storage conditions……………………. -10 °C to +55 °C, 5% to 80% RH, non-condensing
- Weight……………………………………. 101 g
- Dimensions……………………………… 128 x 120 x 44 mm (L x W x H)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g.
photocopying, microfilming or capturing in electronic
data processing systems) requires prior written approval from the publisher.
Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE.