Fresair S8 Golf Cart Kit User Manual

July 31, 2024
fresair

Fresair S8 Golf Cart Kit

Specifications

  • Main Components: Inner Light, Top Cover, Air Diffuser, Control Panel, Cover Straw Filter Cover Filter Set, Fan Bracket Fan Cover Fan, Internal Base Filter Base PreFilter Water Pump, Base Sealing Control Panel Main Panel, Finishing Frame
  • Fan Speeds: 5 levels

Product Usage Instructions

Main Components:
The Fresair Air Cooling Unit consists of various components including the fan, water pump, control panel, and filters. Make sure all components are properly assembled according to the provided manual.

Turning the Unit On/Off:
To turn the fan on and off, press button 5. Use button 8 to adjust the fan speed levels. Press the pump button to activate or deactivate water circulation. The water pump starts automatically when the fan is turned on if there is water in the reservoir.

Low Water Indicator:
When the LOW WATER LED blinks, it indicates low water level. If the water is completely depleted, the pumps will shut off. Refill the water tank to resume cooling operation.

Control Panel Functions:
The control panel allows you to manage various functions such as turning on/off the interior light, adjusting fan speeds, and monitoring water pump status. Follow the provided guide to navigate through different settings.

FAQ

  • Can the Fresair Air Cooling Unit be used while driving?
    Yes, the unit is designed for stationary use but can also be used while driving.

  • What should I do if the low water indicator turns on?
    Refill the water tank to ensure uninterrupted cooling operation. The pumps will shut off if water is completely depleted.

Dear User

  • Congratulations on your new purchase! As a Fresair Air Cooling Unit owner, you’re about to enjoy the fruits of an innovative, high quality product designed exclusively to provide you with extreme comfort in hot climates.
  • We take pride in our products and want you to feel confident installing and operating the Fresair Air Cooling unit, that’s why we prepared this manual.
  • Here you will find simple instructions for step-by-step installation, optimal performance, and operational procedures so you can get the most out of your Fresair.

Main Components

  • Fan On/Off: Press button ➎ to turn the fan on and off

  • Fan Speed: Press button ➑ to cycle through fan power levels (5 fan speeds.)

  • Pump On/Off : Press button ➏ to turn water circulation on and off.
    Note: When you turn the fan on the water pump automatically starts (if there is water in the reservoir.)

  • Low Water: When the water tank level is low the “LOW WATER” LED ➋ starts blinking. The light will remain solid when water is completely depleted at which point pumps will shut off. Refill the water tank to resume normal cooling operation.

  • Interior Light: Press button ➐ to turn the interior light on and off.

Control Panel / Remote Control Functions:

  1. Interior LED Light On/Off
  2. Water Pump On/Off
  3. Decrease Fan Speed
  4. Sleep Programming
  5. Increase Fan Speed
  6. Water Pump On Indicator (green)
  7. Low Water Indicator (yellow)
  8. Battery Indicator (red)
  9. Sleep Indicator (blue)
  10. Bluetooth Indicator (blue)
    External Lighting On/Off (unavailable)
    Fan On/Off

Safety Information

Explanation of Symbols

  • CAUTION!
    Safety Instruction: Indicates a hazardous situation that, if not avoided, could result in serious, minor or moderate injury.

  • NOTICE!
    Indicates a situation that, if not avoided, can results in property damage.

  • NOTE
    Supplementary information for operating the product.

Safety
The manufacturer accepts no liability for damage in the following cases:

  • Damage to the product resulting from mechanical influences and incorrect connection voltage.
  • Alterations to the product without express permission from the manufacturer
  • Use for purposes other than those described in the operating manual.

Handling the Product

  • Only use the Fresair Air Cooling Unit for the purpose specified by the manufacturer and do not make any alterations or structural changes to the device.
  • Do not use the Fresair Air Cooling Unit if it is visibly damaged.
  • Installation and repairs to the Fresair Air Cooling Unit may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause serious hazards. People
  • (including children) whose physical, sensory or mental capacities or whose lack of experience or knowledge prevent them from using this product safely should not use it without the supervision or instruction of a responsible person.
  • Electrical devices are not toys.
  • Children must be supervised to ensure that they do not play with the product.
  • Do not undo the upper cover of the Fresair Air Cooling Unit in case of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
  • Do not reach into air vents or insert any foreign objects in the system.
    CAUTION!
    Disconnect all power supply lines when working on the unit (cleaning, maintenance, etc.)

Intended Use

  • The Fresair Air Cooling Unit is used to supply the interior with cool air.

  • The system is designed for stationary use. It can be used while driving.
    NOTE
    Only install the Fresair Air Cooling Unit using the installation instructions provided in the manual.

  • The Fresair unit uses minimal 12V power to pull air from the outside of the vehicle, through an anti-bacterial and anti-fungal pine straw filter, delivering strong directional air through the four adjustable air vents. With the cooling mode on, the pine filter is gradually wetted through a drop system, by repetitive injection and return of circulating water from the water reservoir. The pine straw filter is never oversaturated and water usage is conserved by this regular flow of water between the reservoir and the unit. The resultant air flowing into the vehicle is cooled by an evaporative process.

  • The unit will continue to produce cool air until it is turned off, the connected power source is depleted, or the water reservoir is exhausted.

  • The unit can be used both with or without water circulation. To use it without, power on the Fresair unit and power off the pump on the control panel. With no water circulating the system acts like a simple directional fan without cooling.

  • The system is controlled using the control panel or the included remote control.
    NOTE
    The Fresair Air Cooling unit can lower the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your unit. For the cooling capacity of your unit, see “Technical data” on page 7.

Technical Data

Height 3.7 inches
Width 33 inches
Depth 25 inches
Weight 25 pounds
Average Water Consumption 500 to 1500 ml/h depending on the external

moisture and temperature
Capacity| 8L or 5L water tank
Autonomy| 15-22 hours
Fan| Double fan with ohmic resistance
Voltage| 12V
Maximum Nominal Current| 12V/10A
Fan Speed| 4000 rpm
Weight Maximum Air Flow| 400 m³/h
Insulation Class| 1Ω

Technical Data

NOTE
These figures are estimates based upon aggregated data. Fresair is not responsible for exact achievable temperatures or comfort zones as installations differ.

Technical Assistance

  • Fresair is committed to providing guidance to ensure optimal performance, understanding routine maintenance and preventative care.
  • Should you need any assistance or guidance on performance, preventative care, maintenance or general questions please contact an authorized dealer or reach out to us directly at support@fresair.com.
  • Additionally, we have outlined some of our go to resources for questions and/or troubleshooting remedies that can help to answer your questions.

Operation Information

NOTICE!
The manufacturer assumes no liability for non-observance of this operating manual, in particular for any consequential damage(s), especially consequential damage(s) caused by failure of the Fresair Air Cooling unit. Do not insert foreign objects into the system.

Observe the following instructions to ensure your Fresair Air Cooling Unit is used properly and efficiently.

It is recommended that you:

  • Park your vehicle in the shade when possible.
    If you leave your vehicle and your unit is in off mode and the vehicle is not ventilated, make sure to open a window, door, or vent when you return in order to release hot air and more quickly introduce cool air.

  • Select a suitable fan speed by increasing or decreasing the speed until the desired speed is achieved.

  • Use the any or all of the 4 directional vents to point the airflow to the desired areas. Ensure water reservoir is full.

  • The water pump automatically turns on when the unit is turned on provided there is water present in the reservoir.

  • Keep the water pump on for maximum cooling performance.

  • The best cooling capacity is achieved when the fan is at maximum speed, the pump is on and the directional vents are directed toward you.

Operation

  • With the system switched off, press the button.
  • The Power LED and Water Pump LED light up.
  • The fan and water pump starts.
  • If you wish for the unit to operate without the water press the button to turn the water pump off.
  • To increase or decrease the airflow press the button.
  • To turn the interior light on or off press the button.

Warranty Information

  • The warranty period begins on the purchase date and ends 12 months from the purchase date with exceptions to certain replacement parts as outlined in the manual.
  • If the product is defective, please contact the dealer you purchased from or contact Fresair directly by emailing support@fresair.com. For repair and warranty processing, please include a copy of the receipt with purchase date and a reason for the claim and/or description of the fault.
  • In no case will Fresair exchange the product for a replacement solely due to a defective component.
    • Damages caused by accidents;
    • Plastic items: superior cover in ABS plastic, main panel, finishing frame and base;
    • Electric harness or hoses cut or damaged;
    • Control panel with any sign of modification or use with other brand;
    • Fan with broken or damaged airscrew or with normal brush wear and tear;
    • Air filter obstructed by dirt or dust;
    • Any component in which the label with the date of manufacture is removed or not legible;
    • Use of unauthorized parts, unauthorized modifications, or unauthorized repairs made by technicians or individuals who are not licensed or not qualified to modify or repair Fresair units;
    • Off road application;
    • Unsatisfactory product performance due to improper installation;
    • Damage caused by unexpected circumstances (ex: accident, fall, wear and tear, violent weather conditions, use of chemical abrasive products inside and outside the product, etc.);
    • If the product is switched on at a different voltage than it was intended for;
    • Removal of and/or modification of the serial number or the product identification label.
      NOTICE!
      If kept in off mode for an extended period of time, there may be an odor when turning it on again as a result of the absence of water cycling through the straw filter. You may remedy this by running a few cycles and the odor will naturally subside.
      NOTICE!
      This model has exclusive application for on road uses. We do not recommend extreme off road uses at this time.
      NOTICE!
      Never add anti-freeze, softener, perfume, fragrance or any other substance than pure water in the reservoir. Adding substances could create foam or potentially cause leaks.

Parts: Maintenance

  • Fan: Located in the center of the tray, the fan draws in external air and blows internal air through the 4 directional vents.
    NOTE
    The fan contains carbon brushes that can degrade over time. We recommend replacing every 4 years.

  • Evaporative Straw Filter: Located in the tray, external air is pulled through the moistened straw causing evaporation over a large surface area resulting in the cooling of the passing air which is delivered to the internal vents. It also filters out dust, insects, and acts as a humidifier in very low humidity environments.
    NOTE
    We recommend inspecting the filter and washing with a hose every 3-6 months to remove dirt and debris. Depending on usage we recommend replacing the filter every 12 months.

  • Tray Internal Filter: An internal filter located in the tray which is responsible for filtering the excess water descending from the straw filter. The water is then recycled and returned to the water reservoir
    NOTE
    We recommend inspecting and gently washing the filter every 6 months. Excess amounts of dirt could prevent water from cycling through, possibly cause water leakage.

  • Tray Pre-Filter: Also located in the tray and is responsible for a second filtering process, avoiding the entry of dirt into the pump, protecting the pump from clogging and breaking down.
    NOTE
    We recommend inspecting and gently washing the filter every 6 months. Dirt can gradually accumulate which overtime lowers the equipment’s performance and can cause eventual water leakage.

  • Water Pumps

    • INJECTION: The injection pump is located on the outside of the water reservoir and sends water to the Fresair unit.
    • RETURN: The return pump is located in the tray and returns excess water to the reservoir.
      NOTE
      We recommend removing the pumps every 6 months and cleaning them with an air blast. Additionally, we recommend changing the pumps every 12 months.
  • Float Sensor: The sensor buoy is attached to the water tank and monitors the water level. If the tank is full and the low water warning light remains on, check that the sensor is inserted correctly in the reservoir with the green dot facing up. If the sensor is inserted correctly and the light remains on it should be replaced.

  • Control Panel: The control panel controls all the product functions. The panel is equipped with an internal safety circuit against motor and pump short-circuits. Should your unit stop working, always check the fan motor and pumps first. The control panel may turn off, protecting itself against some other electrical defects. If the control panel is completely dead, check the main fuse to the battery.

NOTICE!
Periodical maintenance is essential for optimal performance and prolonging the life of your Fresair Air Cooling unit. We recommend preventative maintenance and replacing of wearable parts annually or as outlined in the manual, coinciding with your yearly vehicle maintenance.

Parts: Installation

Loose Components

Bag #1

Water Reservoir

Bag #2

Bag #3

Cleaning & Care

Please observe the following tops for the cleaning and care of your Fresair Air Cooling Unit.

  • Clean the external cover of the unit removing dirt and debris on and around the unit as often as you wash your vehicle.

  • Check regularly that all the internal and external elements are fastening and tighten when necessary. Be careful not to over tighten as you could warp or crack the base.

  • Check regularly that the connection lines are undamaged and secure.

  • Check the filter every 6 months and replace every 12 months.

  • Gently wash the trey internal filter every 6 months.

  • Gently wash the trey pre-filter every 6 months.

  • Remove the pumps every 6 months and clean them with an air blast. Change the pumps every 12 months.