WARNING
Risk of fatal electric shock from touching live connections. Before working on
the controller always switch off the 230V power supply and prevent it from
being accidentally switched on.
Must be mounted on a flat surface, screws max. Ø 3 mm.
A) 230V power (factory installed).
B)) 230V pump output, max. load 0,5 A. Connect “brown” to L and “blue” to N.
Cables must be secured.
C) D) Actuator. Connect “brown” to L and “blue” to N. Cables must be secured.
Use Roth Project actuators 230V 1 Watt, HVAC no. 7466275430. Max. 2 pcs. per
channel.
Pairing/registering the thermostat. All connections must be made to the
Controller (pump, actuator before start-up. Please see controller manual for
details. Press the registration button on the left side of the control unit
(see picture 6) and then press the registration button on the room thermostat
(see picture 7). The temperature is now shown in the display.
Attention! Do not press the buttons on the front of the thermostat whilst
pushing the pairing button on the rear (see picture 7).
Press the registration button again to register an additional thermostat.
The thermostat is now connected to the channel. Make sure Ch.1/Ch.2 on the
Controller light up when the room thermostat calls for heating.
Roth Touchline® SL Standard Room thermostat
Push lightly on the snap lock with a finger or screwdriver (if mounted on the
wall) to slide the backplate of the thermostat.
Insert batteries (included), be aware of +/- polarity.
Mount backplate on the wall (screws not incl.) thermostat slides onto back
plate.
If you want to use the thermostat as a free-standing, the supplied foot can be
mounted in the back plate before it’s mounted again. The thermostat can be
connected to all Controllers in the Roth Touchline® SL series.
Roth underfloor heating system
|
In sleepmode the current temperature is displayed.
To set/change temperature press < > buttons. Confirm by pressing £ or wait 5
sec.
---|---
| You can switch between temperature display and relative humidity display by
briefly pressing the £ button.
| Enables you to view battery level. Select “Bat”, the display flashes.
Confirm within 5 sec. after which the battery level is displayed in
percentage %.
|
Enables you to lock the buttons. Select “Yes” by using one of the buttons < >,
confirm by pressing £ or wait 5 seconds. When the lock is active, the keys are
locked automatically after 10 seconds of inactivity. To unlock, press and
hold the bottons < > for 10 sec. The keys are accessible when the display
returns to showing the current temperature. The key lock is activated until
you inactivate it in the menu.
|
Enables you to return the room thermostat to the factory setting. Select “dEF”
and the display flashes and shows the selected value. Select/confirm (Yes)
with < > buttons within 5 sec. Confirm by pressing £ or wait 5 sec. and the
factory settings has be restored.
| Sensor calibration value. “Cai”.Value can not be changed
|
Enables you to return from the MENU manually. After selecting ”rEt” the screen
flashes for 5 sec. and returns to view of the current temperature.
Roth Touchline® PL room thermostat
Remove screw and slide backplate off.
Insert batteries (included), be aware of +/- polarity.
Mount backplate on the wall (screws not incl.) thermostat slides onto back
plate.
| In sleepmode the current temperature is displayed. To set/change temperature
press +/- button.
---|---
|
Enables you to view battery level. After selecting ”Bat” the screen flashes
for 3 sec. and the level is displayed.
|
Enables you to view the sensor calibration value. After selecting ”Cal” the
screen flashes for 3 sec. and the value is displayed.
Value can be changed on the Controller, please see user manual.
|
Enables you to lock the buttons. After selecting ”Loc” the screen flashes for
3 sec. You can choose/confirm to activate the lock with yes/no. After
activating ”Loc” (yes) the lock will be activated after 10 sec. of inactivity.
To unlock press and hold +/- and when ”Ulc” appears the buttons are unlocked
| Enables you to restore factory settings on the sensor. After selecting ”Def”
the screen flashes for 3 sec. you confirm/choose (yes/ no) with +/ – button
and after 3 sec. the reset will be done.
| Enables you to return from the MENU manually. After selecting ”Ret” the
screen flashes for 3 sec. and you return to view of
the current temperature.
https://roth.support/projectline
ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com
roth-uk.com
ROTH DANMARK A/S
Centervej 5
3600 Frederikssund
Tlf. +45 4738 0121
E-mail: service@roth-danmark.dk
roth-anmark.dk| ROTH SVERIGE AB
Höjdrodergatan 22
212 39 Malmö
Tel. +46 40534090
Fax +46 40534099
E-mail: service@roth-sverige.se
roth-sverige.se| ROTH NORGE AS
Billingstadsletta 19
1396 Billingstad
Tel. +47 67 57 54 00
E-mail: service@roth-norge.no
roth-norge.no
facebook.com/RothNorge| ROTH FINLAND
OY
Raaseporintie 9 (Talo 2)
10600 Tammisaari
Puh. +358 (0)19 440 330
S-posti: service@roth-finland.fi
roth-finland.fi
facebook.com/RothFinland
---|---|---|---
Installation Roth Touchline® PL controller 2ch_20220324
References
- borger.dk - din indgang til det offentlige
- Frontpage | Norge.no
- Hej! Welcome to sweden.se – the official website of Sweden
- UK.COM
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>