BEGA 24 491 Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
BEGA 24 491 Wall Luminaire Instruction Manual
Application
Wall luminaire with asymmetrical light distribution.
For lighting wall and ground surfaces.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Safety glass, antireflection-coated Silicone gasket
Reflector surface made of pure aluminium
Mounting plate with 3 elongated holes, Width 6.5mm · 80 x 145mm spacing 2
screw cable glands with strain relief
for through-wiring power connecting cable ø 7–12mm
1 screw cable gland closed at the factory with a dummy plug
Connecting terminal 2.5@ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 66
Dust-tight and protection against strong water jets
Impact strength IK08
Protection against mechanical impacts < 5 joule
– Safety mark
– Conformity mark
Weight: 7.2 kg
This product contains light sources of energy efficiency class(es) C
Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated and emits less than 1% of the luminaire luminous flux into the upper halfspace of the luminaire.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 62 W
Luminaire connected wattage 67 W
Rated temperature ta=25 °C
Ambient temperature ta max=45 °C
24 491K3
Module designation LED-1095/830
Colour temperature 3000 K
Colour rendering index CRI >80
Module luminous flux 12040 lm
Luminaire luminous flux 9336 lm
Luminaire luminous efficiency 139,3 lm/W
24 491K4
Module designation LED-1095/840
Colour temperature 4000 K
Colour rendering index CRI >80
Module luminous flux 12380 lm
Luminaire luminous flux 9600 lm
Luminaire luminous efficiency 143,3 lm/W
- preliminary data
Installation
Undo hexagon socket head screws (wrench size 3mm) up to the stop and
disassemble the mounting plate.
Pass the power connecting cable through the cable entry in the mounting plate.
The installed black gasket insert is intended for cables ø < 10mm.
For cables ø 10-12mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the
enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket
insert and thrust screw (wrench size 22 mm) (see sketch).
Fix the mounting plate with enclosed or any other suitable fixing material
onto the mounting surface.
Tighten screw cable gland.
Make earth conductor connection and electrical connection to the connecting
terminal (plug connection).
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Make sure that gasket is positioned correctly.
Push plug into coupler as far as it will go.
Place the luminaire onto the mounting plate and fix it.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass with frame graphite 25 000 081
LED power supply unit DEV-0356/1400i
LED module 3000 K LED-1095/830
LED module 4000 K LED-1095/840
Reflector 76 001 961
Gasket wall box 83 001 097
Gasket glass frame 83 001 971
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com