Safety The installation and operation of this luminaire are subject to

national safety regulations. Installation and commissioning may
only be carried out by a qualified electrician. The manufacturer
accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the
luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage Protection| The electronic components installed in the luminaire are
protected against overvoltage in accordance with DIN EN 61547. To
achieve an additional protection against e.g. transients, etc. we
recommend separate overvoltage protection components. You can find
them on our website at www.bega.com.
Lamp Module Connected Wattage| 11.6 W
Luminaire Connected Wattage| 15.5 W
Rated Temperature| Ambient temperature: 25-45°C
Colour Temperature| 3000 K
Colour Rendering Index (CRI)| CRI > 90
Module Luminous Flux| 1725 lm
Luminaire Luminous Flux| 1026 lm
Luminaire Luminous Efficiency| 66.2 lm/W

Product Usage Instructions

Installation:

  1. Avoid touching the light output opening of the LED directly during installation or relamping.
  2. Before installing onto the ceiling, insert the luminaire mounting plate into the luminaire housing.
  3. Pass the mains supply cable through the grommet into the luminaire mounting plate.
  4. Fix the mounting plate inside the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  5. Dismantle the mains supply cable approximately 60 mm.
  6. Pull silicone sleeves over the wires and make earth and electrical connection to the terminals.
  7. Remove the synthetic cover by turning it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Spares:

Part Product Code
Synthetic Cover 15 000 424 71 001 759 L12 75 001 898 .1K 3
Shield 15 000 424 71 001 759 L12 75 001 898 .1K 3
LED Unit (3000 K) 15 000 424 71 001 759 L12 75 001 898 .1K 3

Dimension

Ceiling luminaire for indoor useBEGA-51012.2-Ceiling-Luminaire-fig
1

Application

  • Ceiling luminaire · indoor luminaire impact resistant synthetic diffuser and metal housing for non-glare light deflected downwards.

Product description

  • Ceiling luminaire »STUDIO LINE«

  • Luminaire housing made of aluminium, surface Colour velvet black

  • inside hue aluminium matt

  • Metal luminaire mounting plate, finish Colour velvet black

  • Impact resistant synthetic diffuser, white, with bayonet closure

  • 2 mounting holes ø 5.5 mm

  • Distance apart 180 mm

  • 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@

  • Connection terminal 2.5@

  • Earth conductor connection

  • LED power supply unit

  • 220-240 V y 50-60 Hz

  • BEGA Thermal Switch®

  • Temporary thermal shutdown to protect temperature-sensitive components
    Safety class I

  • Impact strength IK10

  • Protection against mechanical

  • impacts < 20 joule

  • – Safety mark

  • – Conformity mark

  • Weight: 1.6 kg

  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 11.6 W

  • Luminaire connected wattage 15.5 W

  • Rated temperature ta = 25 °C

  • Ambient temperature ta max = 45 °C
    51 012.2 K3

  • Colour temperature 3000 K

  • Colour rendering index CRI > 90

  • Module luminous flux 1725 lm

  • Luminaire luminous flux 1026 lm

  • Luminaire luminous efficiency 66,2 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.BEGA-51012.2-Ceiling-Luminaire-fig 4

  • Before installing onto the ceiling the luminaire mounting plate must be inserted into the luminaire housing. Thereby pass the mains supply cable through the grommet into luminaire mounting plate.
  • Fix monting plate inside the luminaire housingwith enclosed or any other suitable fixing material on to the mounting surface.
  • Dismantle the mains supply cable approx. 60 mm.
  • Pull silicone sleeves over the wires and make earth and electrical connection to the terminals. In order to securely install the synthetic cover in the fitting, the top opening of the synthetic cover must be inserted into the luminaire housing at an angle.
  • Make sure that at least one of the recesses in the edge of the synthetic cover matches the position of one of the lugs on the fitting – see drawing.

IMPORTANT:

  • Turn the synthetic cover upwards into the fitting as far as it will go. Now secure the synthetic cover in the fitting by turning it clockwise.
  • Only then is the synthetic cover held securely in place and resistant to vibration.
  • The synthetic cover is removed by turning it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED unit

  • The designation of the LED unit is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Unscrew synthetic diffuser from luminaire housing by turning it counter-clockwise.
  • Disassemble LED unit.
  • Assemble LED replacement unit.
  • Note installation instructions of the LED unit.
  • Screw in synthetic diffuser by turning it clockwise.
  • A damaged synthetic diffuser must be replaced.

Spares
Synthetic cover 15 000 424
Shield 71 001 759 L12
LED unit 3000 K 75 001 898 .1K 3

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com