BEGA 77 090 Surface Mounted Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
Surface-mounted luminaire
77 090
Technical amendments reserved
Instructions for use
Application
Surface-mounted luminaire with four-sided light sectors.
Drive-over luminaire for vehicles with pneumatic tyres.
For the various requirements at the installation site, we offer a connection
housing as a accessory.
The luminaires can thus be installed on unpaved surfaces.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture
is exposed to a horizontal strain due to braking, acceleration and change of
direction.
Product description
Luminaire made of aluminium alloy and stainless steel
BEGA Unidure® coating technology Borosilicate glass Silicone gasket
Luminaire with mounting plate for bolting onto a foundation or onto a
connecting housing Mounting plate made of stainless steel
Steel grade number 1.4301 3 fixing holes ø 9 mm
Angle 120° · Pitch circle ø 132 mm 1,8 m water-resistant connecting cable
H07RN8-F 3 G 1,5@ with implemented water stopper and 1.2 m PVC cable conduit
LED power supply unit 220-240 V 0/50-60 Hz
DC 176-280 V
Safety class I
Protection class IP 67
Dust-tight and protection against temporary immersion
Pressure load 1,000 kg (~10 kN)
Impact strength IK10
Protection against mechanical impacts < 20 joule
Maximum surface temperature 30 °C
(measured according to EN 60598 of ta 15 °C)
– Safety mark
– Conformity mark
Weight: 2.8 kg
This product contains light sources of energy efficiency class(es) G
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
Disassemble mounting plate in the luminaire housing by undoing screws up to
the stop (by turning them approx. 1.5 revs).
Turn luminaire housing and lift it off.
Installation on foundations provided by the customer or on other paved
surfaces (ill. A):
For the electrical connection and for accepting the connecting cable with
water stopper a cavity of ø 100 mm is required under the luminaire at site.
Sufficient drainage must be provided. If the luminaire connecting cable is
laid in the soil the enclosed protective conduit must be used.
Fix mounting plate with enclosed or any other suitable fixing material onto
the foundation.
Installation onto a connection housing (ill. B):
Fix mounting plate onto the connection housing (BEGA accessory 71 246).
The electrical connection must be carried out with matching protection class
and safety class with suitable connection terminals (not included in the scope
of delivery) at the luminaire power supply cable.
We recommend the use of distribution box 70 730.
Make the earth conductor connection and the electrical connection.
To protect the luminaire connecting cable from damage push the enclosed cable
conduit over the cable.
Place luminaire housing onto the mounting plate, align and tighten.
Lamp
Module connected wattage | 11.8 W |
---|---|
Luminaire connected wattage | 13.4 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
77 090 K27
Module designation | 2x LED-0258/827 |
---|---|
Colour temperature | 2700 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 1740 lm |
Luminaire luminous flux | 264 lm |
Luminaire luminous efficiency | 19,7 lm / W |
77 090 K3
Module designation | 2x LED-0258/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 1750 lm |
Luminaire luminous flux | 265 lm |
Luminaire luminous efficiency | 19,8 lm / W |
77 090 K4
Module designation | 2x LED-0258/840 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 1860 lm |
Luminaire luminous flux | 282 lm |
Luminaire luminous efficiency | 21 lm / W |
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Corrosive chemicals must not come in contact with the luminaire.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the electrical installation.
Clean dirt and deposits from key openings of screw head.
Do not use a high pressure cleaner.
Open the luminaire and clean.
Use only solvent-free cleaners.
The luminaire housing must be completely clean and absolutely dry.
Please follow the installation instructions for the LED module.
Check all screws and threads thoroughly and grease them.
Check the gasket and replace, if necessary.
A broken glass must be replaced.
Close the luminaire.
Accessories
71 246 Connection housing made of galvanised steel Total length 225 mm
70 730 Distribution box with 7 cable entries Connection terminals 5 x 4@
For the accessories a separate instructions for use can be provided upon
request.
Spares
Spare glass
LED power supply unit
LED module 2700 K
LED module 3000 K
LED module 4000 K
Gasket| 11 002 888
DEV-0136/700
LED-0258/827
LED-0258/830
LED-0258/840
83 001 716
---|---
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>