BEGA 77 090 Surface Mounted Luminaire Instruction Manual

June 13, 2024
BEGA

Surface-mounted luminaire
77 090
Technical amendments reserved

BEGA 77 090 Surface Mounted Luminaire - fig 1

Instructions for use

Application

Surface-mounted luminaire with four-sided light sectors.
Drive-over luminaire for vehicles with pneumatic tyres.
For the various requirements at the installation site, we offer a connection housing as a accessory.
The luminaires can thus be installed on unpaved surfaces.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Product description

Luminaire made of aluminium alloy and stainless steel
BEGA Unidure® coating technology Borosilicate glass Silicone gasket
Luminaire with mounting plate for bolting onto a foundation or onto a connecting housing Mounting plate made of stainless steel
Steel grade number 1.4301 3 fixing holes ø 9 mm
Angle 120° · Pitch circle ø 132 mm 1,8 m water-resistant connecting cable
H07RN8-F 3 G 1,5@ with implemented water stopper and 1.2 m PVC cable conduit
LED power supply unit 220-240 V 0/50-60 Hz
DC 176-280 V
Safety class I
Protection class IP 67
Dust-tight and protection against temporary immersion
Pressure load 1,000 kg (~10 kN)
Impact strength IK10
Protection against mechanical impacts < 20 joule
Maximum surface temperature 30 °C
(measured according to EN 60598 of ta 15 °C)
– Safety mark
– Conformity mark
Weight: 2.8 kg
This product contains light sources of energy efficiency class(es) G

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Installation

Disassemble mounting plate in the luminaire housing by undoing screws up to the stop (by turning them approx. 1.5 revs).
Turn luminaire housing and lift it off.

BEGA 77 090 Surface Mounted Luminaire - fig 2

Installation on foundations provided by the customer or on other paved surfaces (ill. A):
For the electrical connection and for accepting the connecting cable with water stopper a cavity of ø 100 mm is required under the luminaire at site.
Sufficient drainage must be provided. If the luminaire connecting cable is laid in the soil the enclosed protective conduit must be used.
Fix mounting plate with enclosed or any other suitable fixing material onto the foundation.

Installation onto a connection housing (ill. B):
Fix mounting plate onto the connection housing (BEGA accessory 71 246).
The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
We recommend the use of distribution box 70 730.
Make the earth conductor connection and the electrical connection.
To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
Place luminaire housing onto the mounting plate, align and tighten.

Lamp

Module connected wattage 11.8 W
Luminaire connected wattage 13.4 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

77 090 K27

Module designation 2x LED-0258/827
Colour temperature 2700 K
Colour rendering index CRI > 80
Module luminous flux 1740 lm
Luminaire luminous flux 264 lm
Luminaire luminous efficiency 19,7 lm / W

77 090 K3

Module designation 2x LED-0258/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 1750 lm
Luminaire luminous flux 265 lm
Luminaire luminous efficiency 19,8 lm / W

77 090 K4

Module designation 2x LED-0258/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 1860 lm
Luminaire luminous flux 282 lm
Luminaire luminous efficiency 21 lm / W

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Corrosive chemicals must not come in contact with the luminaire.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the electrical installation.
Clean dirt and deposits from key openings of screw head.
Do not use a high pressure cleaner.
Open the luminaire and clean.
Use only solvent-free cleaners.
The luminaire housing must be completely clean and absolutely dry.
Please follow the installation instructions for the LED module.
Check all screws and threads thoroughly and grease them.
Check the gasket and replace, if necessary.
A broken glass must be replaced.
Close the luminaire.

Accessories

71 246 Connection housing made of galvanised steel Total length 225 mm
70 730 Distribution box with 7 cable entries Connection terminals 5 x 4@
For the accessories a separate instructions for use can be provided upon request.

Spares

Spare glass
LED power supply unit
LED module 2700 K
LED module 3000 K
LED module 4000 K
Gasket| 11 002 888
DEV-0136/700
LED-0258/827
LED-0258/830
LED-0258/840
83 001 716
---|---

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com