Make Your Motion and Control More Accurate!
E53.C1K-K/E53.C4K Piezo Motor Controller Software
User Guide
1.Select Control Mode >>
(1) Select the corresponding serial port.
(2) Click “Set Serial Port”.
(3) Click “Piezo Motor Control”.
2.Display Interface >>
Control
Select channel No., there 4 channels could be selected, and it could be
operated one channel at a time.
Step motion(steps)
In the current position, relative forward motion or reverse motion could be
chosen. In the moving cycle, the channel position information could be
obtained. Click “Forward”, the piezo linear actuator will move in one
direction, and the reverse motion will move in a relatively positive
direction. Adjust it according to the actual application.
High Resolution
Used for tiny steps. Low resoluiton: usde for quick movement. High resolution
and low resolution, the two are relatively theory.
Continuous Motion
Continuous forward means moving until the maximum position of piezo actuator
positive, or click “Stop” button at a certain point of time to stop the
movement.
Continuous reverse and continuous positive opposite directions, control and
motion stop are similar.
Position Info.
Click “Acquire”, it will display the value of the current control channel
recorded by the piezo controller.
Click “Empty” to clear the value of the current control channel by the
controller.
Foward/Reverse Control
Fill in the running time, then click “Start”, the piezo actautor reciprocating
motion for specified time. Click “Stop” to stop the movement.
Acquire Amplifier Info.
Reading the piezo controller version information.
3.Exit System >>
Complete the operation and exit the system.
7.Zero Calibration >>
It indicates that piezo motor finds the absolute zero position of grating ruler, and returns to the absolute position before calibration after finding it.
8.Return Zero >>
It indicate that piezo motor returns to zero position, which is generally consistent with absolute zero position of grating ruler.
9.Set >>
Click “Set” button to pop up the device information window.
Harbin Core Tomorrow Science & Technology Co., Ltd.
Tel: +86-451-86268790
Fax: +86-451-86267847
Email: info@coremorrow.com
Web: www.coremorrow.com
Headquarters: Building I2, No.191 Xuefu Road, Nangang District, Harbin
Shanghai Office: Building 2, No.608 Shengxia Road, Pudong District, Shanghai
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>