BEGA 50350.2 Wall Luminaire Instruction Manual

June 13, 2024
BEGA

50350.2 Wall Luminaire
Instruction Manual

50350.2 Wall Luminaire

Technical amendments reserved
Wall luminaire for indoor use

Instructions for use

Application
Wall luminaire · indoor luminaire with velvet white luminaire housing and inside hue. The light emits upwards and downwards.

Product description

Wall luminaire “STUDIO LINE” Luminaire housing made of aluminium, surface Colour velvet white inside hue aluminium matt Reflector made of pure anodised aluminium 2 elongated fixing holes Width 4.5 mm · 90 x 38 mm spacing 1 cable entry for through-wiring for mains cable Connecting terminal 2.5@ with plug connection Earth conductor connection LED-Module for mains voltage 220-230 V y 50/60 Hz BEGA Thermal Switch ®  Temporary thermal shutdown to protect temperature-sensitive components
Safety class I – Safety mark – Conformity mark Weight: 0.8 kg This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc.
we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Luminaire connected wattage 14 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 35 °C

50 350.2 K3

Module designation LED-0608/930
Colour temperature 3000 K
Colour rendering index Ra > 90
Module luminous flux 1320 lm
Luminaire luminous flux 364 lm
Luminaire luminous efficiency 26 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo set screw and lift off luminaire housing. Loosen LED-connection and earth connection (plug connection). Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the luminaire “arrow down”.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).
Make earth conductor connection between luminaire housing and mounting plate. Push LED plug into coupler as fa as it will go. Install luminaire housing over mounting plate and tighten set screw.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified person using commercially available tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.

Spares

LED module 3000 K LED-0608/930

BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com