BEGA 50350.2 Wall Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
50350.2 Wall Luminaire
Instruction Manual
50350.2 Wall Luminaire
Technical amendments reserved
Wall luminaire for indoor use
Instructions for use
Application
Wall luminaire · indoor luminaire with velvet white luminaire housing and
inside hue. The light emits upwards and downwards.
Product description
Wall luminaire “STUDIO LINE” Luminaire housing made of aluminium, surface
Colour velvet white inside hue aluminium matt Reflector made of pure anodised
aluminium 2 elongated fixing holes Width 4.5 mm · 90 x 38 mm spacing 1 cable
entry for through-wiring for mains cable Connecting terminal 2.5@ with plug
connection Earth conductor connection LED-Module for mains voltage 220-230 V y
50/60 Hz BEGA Thermal Switch ® Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I – Safety mark – Conformity mark Weight: 0.8 kg This product
contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc.
we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Luminaire connected wattage | 14 W |
---|---|
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 35 °C |
50 350.2 K3
Module designation | LED-0608/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | Ra > 90 |
Module luminous flux | 1320 lm |
Luminaire luminous flux | 364 lm |
Luminaire luminous efficiency | 26 lm / W |
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo set screw and lift off luminaire housing. Loosen LED-connection and earth
connection (plug connection). Pass the power connecting cable through the
cable entry in the mounting plate.
Note position of application of the luminaire “arrow down”.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface. Make earth conductor
connection. Push silicone sleeves over the lines and make electrical
connection to terminal (plug connection).
Make earth conductor connection between luminaire housing and mounting plate.
Push LED plug into coupler as fa as it will go. Install luminaire housing over
mounting plate and tighten set screw.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified person using commercially available tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.
Spares
LED module 3000 K | LED-0608/930 |
---|
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com
References