BEGA 51108.1 Recessed Ceiling Downlight Instruction Manual

June 13, 2024
BEGA

51108.1 Recessed Ceiling Downlight
Instruction Manual

51108.1 Recessed Ceiling Downlight

Technical amendments reserved
Recessed ceiling downlight for indoor use

BEGA 51108.1 Recessed Ceiling Downlight - indoor

Instructions for use

Application
Recessed ceiling luminaire · indoor luminaire with adjustable symmetrical broad spread light distribution.
Ready-to-connect set of 6 including external phase-dimmable LED power supply unit and connection cables between the luminaires.
For installation in suspended ceilings of 3-18 mm in interior applications.

Product description

Set of 6 ready-to-connect recessed ceiling luminaire downlights including external power supply unit Luminaire housing made of die-cast zinc finish Colour velvet white Reflector surface made of pure aluminium Fixing is achieved by using 2 fastening springs
Recessed opening ø 68 mm Required installation depth 86 mm Connection cable with 2-pole plug connector between luminaires and external LED power supply unit (see sketch) External LED power supply unit 220-240 V y 50-60 Hz Dimmable via a leading-edge or trailing-edge dimmer Safety class II – Conformity mark Weight: 1.0 kg This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 4 W
Luminaire connected wattage 33 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 25 °C

51 108.1 K27

Module designation 6x LED-1208/927
Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 3240 lm
Luminaire luminous flux 1871 lm
Luminaire luminous efficiency 56,7 lm / W

51 108.1 K3

Module designation 6x LED-1208/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 3480 lm
Luminaire luminous flux 2010 lm
Luminaire luminous efficiency 60,9 lm / W

Light technique
Adjustable broad spread light distribution.
Half beam angle 52° Optical system 0-30° swivel-mounted.

Installation

Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.
IMPORTANT: For the luminaire housing and the power supply unit, a clearance of at least 50 mm to the sides of the building is required.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

BEGA 51108.1 Recessed Ceiling Downlight - LED

The ready-to-connect set of recessed ceiling luminaires includes an external phasedimmable LED power supply unit and connection cables with 2-pole plug connector between the luminaires and the LED power supply unit.
Installation in suspended ceilings:
For each luminaire, a recessed opening of 68 mm with a minimum depth of 86 mm is required.
The minimal thickness of the ceiling panel must be 3 mm and must not be greater than 18 mm.
A ceiling panel with less than 3 mm thickness must be reinforced on the reverse.
The electrical connection must be made on site in the appropriate safety class on the LED power supply unit connecting cable. A distribution box must be used.
Ensure the correct assignment of the connecting cable. Establish the mains connection on the brown (L) and blue (N) wires. Guide the LED power supply unit and connection cable with distribution boxes through the ceiling opening and deposit them in
the suspended ceiling.
Make sure that the plug connectors between connection cables and distribution boxes on the suspended ceiling are connected correctly before connecting the recessed luminaires.
The luminaires are interlinked in a series connection.
IMPORTANT: Make sure that the series circuit is closed via the plug with wire jumper in the distribution box of the last luminaire.
Alternatively, plug this plug with wire jumper into the distribution box socket of the last luminairConnect the plug of the first recessed luminairto the integrated socket of the first distribution box until the latch engages.
Proceed with additional luminaires in the same way.
Cover the recessed opening with the stop ring of the luminaire housing.
The luminaire housing is then fixed in the recessed opening via two springs.
Compress the fastening springs of the luminairhousing on both sides and slide the luminaire housing into the recessed opening.
The fastening springs lock into place behind the ceiling panel.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Close the luminaire.

Spares

LED power supply unit DEV-0454/700
Connecting cable 62 001 256
Connecting cable 62 001 258
Distributor 64 000 636
Plug with wire jumper 64 000 637
LED module 2700 K LED-1208/927
LED module 3000 K LED-1208/930
Reflector 76 002 018

BEGA Gantenbrink-Leuchten KG ·