BEGA 23846.1 LED Ceiling Luminaire Instruction Manual
- June 13, 2024
- BEGA
Table of Contents
31.22 · Technical amendments reserved
23 846.1
Ceiling luminaire for indoor use
Instructions for use
Application
Ceiling mounted luminaire · indoor luminaire with handblown opal glass, satin
matt and aluminium housing, for all lighting tasks in interior applications.
They are ideal for places where a soft and uniform lighting distribution is
required.
Product description
Luminaire made of Aluminium, finish Colour white
Opal glass, satin matt, with screw neck
Silicone gasket
2 mounting holes ø 4.5 mm
Distance apart 69 mm
1 cable entry for mains supply cable up to ø 10,5 mm
Connecting terminals 2.5
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
Safety class I
- Safety mark
- Conformity mark
Weight: 0.55 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. The manufacturer accepts no liability for damage
caused by improper use or installation. If subsequent modifications are made
to the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Lamp
Module connected wattage 3 W
Luminaire connected wattage 4.1 W
Rated temperature ta=25 °C
Ambient temperature ta max=50 °C
23 846.1 K3
Module designation LED-0349/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 445 lm
Luminaire luminous flux 311 lm
Luminaire luminous efficiency 75,9 lm/W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Remove glass from luminaire housing by turning it counter-clockwise.
Undo knurled screws and remove cover plate. Lead the mains supply cable
through the cable entry into the luminaire housing.
Fasten the luminaire housing with the supplied fastening material or other
suitable fastening material to the mounting surface.
It is absolutely essential to use the enclosed protection against accidental
contact.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Make earth conductor connection between cover plate and luminaire housing.
Assemble cover plate.
Screw glass with gasket into luminaire housing.
Make sure that gasket is positioned correctly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass 11 003 073 40R G
LED power supply unit DEV-0303/350
LED module 3000 K LED-0349/930
Gasket glass 83 001 444
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com