Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required. Luminaire with a high protection class.

Lamp
Luminaire with screw base E 27 Lamp output max. 75 W This product contains light sources of energy efficiency class E Supplied lamp BEGA LED lamp 13548 LED Retrofit 7 W · 805 lm · 2700 K dimmable Supplied lamp BEGA LED lamp 13586 LED Retrofit 7 W · 805 lm · 3000 K dimmable Luminaire efficiency: 54% Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Product description
Metal housing, finish Colour white Hand-blown opal glass, satin matt, with sliding-bolt closure 2 mounting holes ø 5.5 mm Distance apart 240 mm 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connection terminal 2.5@ Earth conductor connection Lampholder E 27 Safety class I Protection class IP 44 Protected against granular foreign bodies ≥ 1 mm and splash water Impact strength IK07 Protection against mechanical impacts < 2 joule r – Safety mark c  – Conformity mark Weight: 3.4 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

Pass the mains supply cable through the base plate. Notice position of application »arrow down« when installed at the wall. Fix base of the luminaire with enclosed or any other suitable fixing material on to the mounting surface. It is imperative to use the enclosed gaskets. Make earth and electrical connection to the terminals. Insert lamps. The sliding-bolt closure provides a safe and vibration-resistant holding of glass. Place glass to the base plate and observe that the holding springbolts fit into the notches of the glass. Insert the opal glass into the luminaire base with sliding bolt glass closure and turn the glass clockwise until it is locked. To release the glass from the base plate, turn it counter-clockwise.

Relamping · Maintenance

Disconnect from main supply. Remove glass turning it counter-clockwise. Clean glass. Use only solvent-free cleansers. Change the lamp. Place glass into fitter and turn it clockwise until the stop.

Spares

  • Spare glass 11 002 771 .0R G
  • LED lamp 2700 K 13 548
  • LED lamp 3000 K 13 586
  • Lampholder 63 000 355
  • Reflector 76 000 678

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals