CDVI RX CUBE POWER Bluetooth Controlled Radio Receiver Instruction Manual
- June 9, 2024
- CDVI
Table of Contents
CDVI RX CUBE POWER Bluetooth Controlled Radio Receiver Instruction Manual
Introduction
RX CUBE POWER – Bluetooth controlled radio receiver
The receiver ERONE “Cube Power” is a super heterodyne radio receiver
operating at 433,92 MHz in AM/ASK demodulation.
It is compatible with the full range of remote controls Erone that use the
Keeloq® Hopping code security protocol.
This receiver can be programmed only via Bluetooth using set-up and control
that can be done only using the app : “RX Cube” on a Smartphone ( iOS or
Android ).
Power supply 12-24 Vac/dc autodetect. High power output contacts The equipment
is manufactured in compliance with the provisions of European Directive
2014/30/EU, 2014/35/EU, 2014/53/EU and the provisions of the standard EN
62368-1.
Part-name | F-code | Description |
---|---|---|
SEL2641R433-RCP | F1001000106 | RECEIVER CUBE POWER 12/24V |
Technical Specifications
- Receiver type: Super heterodyne
- Operating frequency: 433,92 MHz – AM/ASK
- Input sensitivity: 118 dBm
- Input load: 50 Ohm
- Power supply: 12 – 24 Vac/dc ( autodetect)
- Consumption max: 120 mA @12Vac
- Peak consumption: 500 mA at power up
- Max switching power: 10 A @ (30 Vdc)
- Contact NO: 6 A @ (30 Vdc) – Contact NC
- Relay number: 1
- Operating modes: Pulse / Latch / Timed
- Release time (Timed mode): from 1 sec. to 23h.59m:59s
- Contacts: C-NO-NC
- Memory capacity: 250 user codes
- TX security code: KeeLoq® Hopping code
- Max code combination number: 264
- Operating temperature: 20°/+65°C
- Housing protection: IP2X
- Overall dimensions: 44 x 58 x 25 mm
- Communication w/mobile phone: Bluetooth
- Standard: BLE 4.2
- IO : Compatibility: Android, iOS
- Release Android: 5.1 and next
- Release iOS: 10 and next
Dimensions|
Warnings
The receiver allocation is very important for the best operation of the
system. Place the receiver far from interference sources such
as big magnetic fields or radio emissions. The distance between 2 receivers
must be at least1,5 m.
- The equipment must be powered from a device that provides a safety extra low voltage (SELV) type LPS ( Low Power Source);
- There must be a suitable disconnecting device to the current drawn by the receiver (90 mA max @ 12Vdc).
Wiring
Compatible transmitters
- Erone – S2TR2641E2-E4-E2M
- Erone – SETR2641AM1, SETR2641AM2
- Erone – S3TR2641T1-T2-T4
- Erone – S4TR2641E1-E2-E4
- Erone – SETR2641TM
- Erone – S7TR2641E4
- Erone – FKT2641E1 – FKTHS2641E1- TTH2641E1
- Erone – S4TR2641E1-E2-E4
- CDVI – GALEOR
Color LED | Description |
---|---|
Green | Power ON |
NO Bluetooth communication
Green-Orange blinking| Bluetooth communication in progress
Orange| Relay excited
The App “RX CUBE”
The setup of the receiver can be done only through the App “Rx Cube”. So,
first of all, download the App from “Apple Store” or “Google Play”. You can
find it both typing the name of the App, “RX Cube”, or searching simply CDVI
and then selecting Rx Cube. Once downloaded, authorize the App to use the
Bluetooth communication. The App will ask even the GPS localization: please
authorize it for the full operating of the Bluetooth BLE.
Start the App and press the scan button: the App begins scanning the surroundings searching for any Rx Cube is running in the range of the Bluetooth signal ( 10 — 30 m ). Much depends on the fixing position of the receiver and whether the communication is direct or passes through walls. At the end of the scanning, the screen will show all the receivers Rx Cube found.
The receiver, by factory, comes with the name “CUBE”. If you power two or more receivers simultaneously, the scanning will list many receivers all identical: it is advisable to power one device at time and possibly rename it individually. The name of the device can have up to 12 characters.
Changing the factory name of the receiver
- Type the default password 11111 (for administrator), click UNLOCK and enter in the main menu.
- Select Settings.
- Type the new name, give OK, then disconnect and make a new scanning..
- The App will display the new name of the receivers.
Password
The access to the receiver has 2 different security levels: ADMINISTRATOR and
INSTALLER.
Factory password for ADMINISTRATOR = 11111.
Factory password for INSTALLER = 00000.
Both can make all the settings. Only the Administrator can change the
passwords, the Installer is not authorized
Memory
Enter the submenu Memory to manage the receiver memory : add or delete
transmitters individually, add or delete a batch of transmitters, delete all
the transmitters, restore the memory to factory settings.
Memorizing transmitters
Individually ( fig. 3)
The memorization can be done directly, pressing the button of the
transmitter to store or specifying its S/N and Facility code. In this case you
must specify the button/s authorized ( you can store up to 4 buttons).
In one block ( fig. 4)
Specify the number of transmitters of the block, the detail of the first
transmitter ( S/N and Facility code ) and the buttons to enable ( A, B, C or
D).
NOTE: The button Format allows to display the numbers in DECIMAL or
HEXADECIMAL format.
Delete transmitters
Individually
Enter the S/N and Facility code of the transmitter to delete and press
DELETE
In one block
Specify the number of transmitters of the block, enter S/N and Facility
code of the first TX and press DELETE
Delete memory
Press DELETE to delete all the transmitters memorized
Factory Default
This option allows to delete all the transmitters and reset the settings to
the factory defaults: pulse mode, time of the timed mode ( 5 sec.), name of
the receiver ( CUBE).
Settings
Clicking on Settings it is possible to set the the relay operating mode:
PULSE, STEP, TIMED. In pulse mode the relay remains activated for the entire
duration of the radio transmission with a min. time of 300 mS. For the Timed
mode it is possible to set the release time of the relay from 1 sec. to 23h :
59m : 59s.
Pulse mode
Step mode
Timed mode
Password
The password can be changed selecting the icon Password on the mail screen.
Only the ADMINISTRATOR is authorized to change the password.
The password set-in-factory are:
- Administrator: 11111
- Installer: 00000
The password is composed by max 5 numeric digits (min 1)
A red message appears if the password is still the factory password.
NOTE: The icon PASSWORD, in the main menu, is RED when at least one of
the two password is still at the factory value
Info
The icon INFO of the main screen allows to display the features of the
receiver: number of TX memorized, revision of the Firmware and release of the
App.
It is possible to list the transmitters memorized: press List..> The screen
displays only 5-6 lines of the list.
Scroll the list taping the center of the screen.
The Serial number of the transmitters can be displayed in Decimal or
Hexadecimal format.
If you select one line, you display the information of a specific transmitter.
For each transmitter it is displayed the FC + S/N and the button active ( A,
B, C or D).
For changing this setting, press one of the 4 buttons and push CHANGE.
From this screen is also possible to DELETE the TX from the memory.
Command
It is possible to activate directly the relay from the App.
Enter the icon “Command” and press the button.
The symbol becomes RED confirming of the relay activation.
Disposal
This product is made up of various types of material, therefore, as indicated
by the symbol in the figure, the product must not be disposed of in with the
household waste.
Dispose in accordance with local current regulations.
Guarantee
The warranty period for this product is 60 months, beginning from the
manufacturer date.
During this period, if the product does not work correctly, due to a defective
component, the product will be repaired or substituted at our discretion.
The guarantee does not cover the plastic container integrity. After-sale
service is supplied at the factory.
Manufacture
Manufactured by: CDVI WIreless SPA – Via Piave, 23
31020 S.Pietro di Feletto (TV) – Italy
Tel: +39-0438-450960 –
Fax: +39-0438-455628
CUSTOMER SUPPORT
CDVI AMERICAS
[CANADA – USA – LATIN AMERICA]
www.cdvi.ca
Manufactured by : CDVI Wireless SPA
Via Piave, 23 – 31020 S.Pietro di Feletto (TV) – Italy
tel: +39-0438-450860 –
mail: info@erone.com
web: www.erone.com
www.erone.com
References
- CDVI Group
- Access Control Solutions Manufacturer - CDVI Americas
- Fabricant de solutions de contrôle d'accès - CDVI Suisse
- Access Control Solutions Manufacturer - CDVI UK
- Home - CDVI Group
- Producent rozwiązań z zakresu kontroli dostępu - CDVI Polska
- Produttore di soluzioni per il controllo degli accessi - CDVI Italia
- cdvi.ma
- Innovativa accesslösningar för alla branscher | CDVI® - CDVI Nordic AB
- Fabrikant van toegangscontrole-oplossingen - CDVI Benelux
- Fabricante de soluciones de control de acceso - CDVI Ibérica
- Fabbricanti di soluzioni per le automazioni- CDVI Wireless | Erone
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>