BEGA 50845.1 LED Large Area Recessed Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

Large-area recessed ceiling luminaire for indoor useBEGA 50845 1 LED
Large Area Recessed Ceiling Luminaire 50 845.1
Instructions for use

Application

Recessed ceiling luminaire · indoor luminaire with impact resistant synthetic diffuser, translucent white and aluminium housing. For installation in suspended ceilings of 1225 mm in interior applications.

Product description

Recessed ceiling luminaire »STUDIO LINE« Luminaire housing made of aluminium inside hue white Recessed opening ø 885 mm Required installation depth 205 mm Luminaire housing with 4 fastening springs and guide bolts Luminaire with impact-resistant  cover made of synthetic material, translucent white with bayonet closure LED power supply unit 220-240 V x 0/50-60 Hz DC 176-270 V During DC operation the LED power is reduced to 15 % DALI-controllable Basic insulation is provided between the mains and control cables BEGA Thermal Control ® Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK07
Protection against mechanical impacts < 2 joule – Conformity mark
Weight: 16.8 kg
This product contains light sources of energy efficiency classes D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage
Luminaire connected wattage
Rated temperature
Ambient temperature
When installed in heat-insulating material| 78.8 W
86 W
ta = 25 °C
ta max = 45 °C
ta max = 25 °C
---|---

50 845.1 K3

Module designation
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency| 4x LED-0704/930
3000 K
CRI > 90
12960 lm
10520 lm
122,3 lm / W
---|---

Notice prior to installation :
The installation of the luminaire must be carried out by 2 persons!

When mounting the luminaires, it must be ensured that the ceiling surface has sufficient load-bearing capacity.
Please check the secure mounting of the luminaires after installation.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

Remove the luminaire housing (installation housing) from its packaging.
Depending on on-site requirements, the steel wire affixed to the top of the luminaire housing can be secured to a non-flammable building component (see drawing).
Cover the recessed opening with the stop ring of the luminaire housing.
The luminaire housing is then fixed in the recessed opening via four adjustable springs.

IMPORTANT:
Place the four protective adhesive foils in the areas where the fastening springs will be screwed into the luminaire housing.
This will protect the inner surface of the luminaire housing during installation in the recessed opening.

Installation into inserted ceilings:
A recessed opening of 885 mm with a minimum depth of 205 mm is required.
Push luminaire housing into the ceiling cut-out and tighten evenly the hexagon socket head screws (wrench size 4) of the four mounting springs.
The mounting springs catch the ceiling facing from the back side. The minimum thickness of the panel must be 12 mm and the maximum thickness 25 mm.
If the ceiling facing has a thickness of less than 3 mm, the facing thickness in the region of the mounting  springs must be increased from the back side.
Pass the power connecting cable through the opening in the installed luminaire housing.
Unpack luminaire.

IMPORTANT: In order to prevent deformation caused by the luminaire’s own weight, do not place it on its curved synthetic cover when outside the packaging!

Remove the adhesive protective foils and replace them with an offset below the four openings on the edge of the housing.
Position the luminaire in such a way that the LED power supply unit at the back of the luminaire is facing up.
Open the cover of the external LED power supply unit.
Make the earth conductor and electrical connection via terminals on the external power supply unit.
For digital control please use the connecting terminals DA, DA at the power supply unit .
In case these connectors are not used the luminaire will be operated at full light output. Close the cover of the external LED power
supply unit.
Luminaire housing and external LED power supply unit must not be covered by any heat insulating materials.

Guide the LED power supply unit through the opening of the luminaire housing and position it on the suspended ceiling.
Pick up the luminaire and carefully guide it into the luminaire housing, taking care not to damage the coloured surface.
The four retaining plates of the luminaire must fit exactly into the four openings on the top edge of the housing.
Secure the luminaire by lifting it over the locking pins and with a twist to the right until you feel a stop.
The luminaire will now be held securely in place and will be resistant to vibration.
Remove all protective foil from inside the luminaire housing once the luminaire is fully installed in the luminaire housing.
The luminaire is removed by lifting it over the locking pins and twisting it anti-clockwise.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleaning agents to remove dirt.
A defective synthetic cover must be replaced.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
A qualified person using standard tools can easily do the replacement.
Disconnect the system from the power supply.
Twist the luminaire anti-clockwise to remove it from the luminaire housing.
Loosen the hex nuts (M4), remove the three sections of the trim ring and lift off the synthetic luminaire cover.
Remove the LED module. Install the replacement LED module.
Please follow the installation instructions for the LED module.
Twist the luminaire in the luminaire housing to the right to secure it.
A defective synthetic cover must be replaced.
Close up the luminaire again in reverse order.

Spares

Synthetic cover
LED power supply unit
LED module 3000 K
Installation housing| 15 000 358 B1
DEV-0403/1800
LED-0704/930
71 003 451 B2
---|---

Technical amendments reserved
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60
· 58689 Menden
· info@bega.com
· www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals