IMPORTANT: IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and
AS/NZS Standards, which require installation in accordance with AS/NZS3000 by
a qualified installer and regular cleaning and maintenance of the equipment.
Products are sold in accordance with the following instructions and SAL
standard terms and conditions of sale, available via
www.sal.net.au.
Due to continued product and information updates, product data sourced from
sol.net.au shall not form part of any contract and or technical performance
guarantee unless expressly confirmed in writing by SAL at the time of order.
ECOLINE MKIII SL9732 LED LINEAR BATTEN product electrical and installation specification effective 21/10/2022.
General product application requirements (if applicable):
-
power before the selection is made, otherwise equipment damage may occur.
-
Recycling – SAL encourages recycling, please consider the environment when disposing of packaging, batteries & components.
-
Switching or test intervals – For optimum product performance, good design practice does not encourage 24/7 operation of lighting products without the provision of a routine switching or regulatory test cycle. As a guide for continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications and a six (6) hour duration for Residential applications should be considered.
-
Product maintenance – In line with the relevant design standards and to protect your investment, it is important to have in place a routine cleaning program that reflects the installation environment and maintains the product in a clean and functional condition.
IMPORTANT – The supply must be isolated before any product maintenance or cleaning is conducted. In addition, damage to ANY cable or cord supplied with the product must be addressed as follows; For attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by an equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the external flexible cable is damaged, it must be exclusively replaced by an equivalent cable by the manufacturer or authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable cannot be replaced and the luminaire must be destroyed. -
Adverse, corrosive and coastal installation environments – Unless the product is specifically designated for such applications in these installation instructions, which is supported by a professional maintenance program: installation of equipment in such environments is not recommended.
-
Dimming products – Dimming circuits and product compatibility must be validated by the installer before installation; SAL cannot be responsible for third party changes in dimmer compatibility.
-
Suspended products – For installation safety, any suspended products must NOT be installed in high air movement spaces or locations subject to impact.
-
Light source replacements – (Non-replaceable light sources) – The light source of the product is deemed not replaceable, when the product reaches its end of life the complete product, it must be replaced by a qualified installer. (Non-user replaceable light sources) – The light source of the product must only be replaced by the manufacturer or qualified installer. Caution, risk of electric shock.
-
Interior downlights and sensors with remote drivers and electrical accessories – The mounting facilities provided for the transformer/driver (if any), need only be utilized if in the application of the product is required by AS3000. Drivers are not designed for installation environments that restrict conventional airflow.
-
Floodlight products – Unless nominated aiming restrictions or installation parameters apply, products are designed for installation environments between ground and 15 metres in height, subject to the desired optical performance being achieved.
-
Emergency enabled products – In the interest of transport and safety, emergency products are supplied with the battery disconnected. In addition to specific emergency commissioning instructions, this battery MUST be connected at the time of installation.
-
Specific installation procedures (if any) – this device must be installed by a licensed electrician:
Wiring Diagrams (For EM models only)
Commissioning and operation (For EM)
- Switch on mains supply. The charge monitor LED will illuminate.
- Allow the unit to operate for 30 minutes and then depress the test switch to check emergency operation.
- Release the test switch and allow the unit to operate for 16 hours to fully charge the battery after which time the unit is ready.
- Self-contained emergency luminaires shall be subjected to a battery discharge test for the required duration at regular intervals in accordance with AS/NZS 2293 applicable to emergency lighting. Batteries should be replaced with the same brand/type when the rated duration is no longer achieved.
Important safety issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- The supply must be isolated before opening or accessing the luminaire.
Note: In the interest of safety, the 6 monthly test should be undertaken during daylight hours to allow for the possibility of failures of the standard lighting supply whilst the battery is discharged.
13. Warranty- In accordance with SAL’s standard terms and conditions of sale, SAL warrant this product to be free from defects in materials and or workmanship for a period as stated below for goods not subject to incorrect installation, maintenance, operation, mishandling, environmental, unauthorised modifications or electrical operating conditions outside the nominated product specification as detailed in these installation instructions. The benefits to you given by this warranty are in addition to other rights and remedies you have under law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Warranty term – Residential usage (60) months, Commercial usage (36) months and Lithium batteries where supplied (24) months from date of purchase. For New Zealand, please refer to www.sal.co.nz for warranty conditions and service.
How to make a claim?
Step# 1 – Within 30 days of the fault discovery, please contact the original
place of the SAL product purchase during standard (local) business hours, with
the following information (a) proof of purchase (b) description and quantity
of the claimed fault (c) address of installation. (d) operating hours of the
product.
Step # 2 – It is then the responsibility of the original place of product
purchase to report the matter to SAL aftersales;
NSW I ACT – SAL National Ply Ltd, 40 Biloela Street Villawood NSW 2163 P # 02
9723 3099
QLD – SAL National Pty Ltd, 36 Whitelaw Place Richlands QLD 4077 P # 07 3879
5999
VICT I TAS I SA I NT – SAL National Ply Ltd, 46-48 Keys Road Moorabbin
Victoria 3189 P # 03 9532 3168
WA – SAL National Pty Ltd, 29 Beringarra Av Malaga WA 6090 P # 08 9248 7458
NZ – Hamer, 130 Bush Road, Albany, Auckland, 0632 P # 0800 239 239
Step# 3 – Upon review of your claim and if the product is required to be
returned to SAL for technical evaluation, then at the owners expense the
product must be returned to SAL as per the above nominated locations.
Step# 4 – Pending the evaluation, the claim will be validated resulting in the product being repaired or replaced with the same or best equivalent product at the discretion of SAL or rejected if the product fault was found to be caused by conditions beyond the responsibility of SAL warranty obligations. Consideration of installation, product removal, return freight and or testing fees are not the responsibility of SAL.
SAL National Pty Ltd. 40 Biloela Street Villawood NSW 2163 ABN 21633189 474 Copyright SAL Vl 2 FEB 2020 I www.sal.net.au