Specifications
- Product Type: LED Driver
- Input Voltage : 100-240V AC
- Output Voltage : 12V/24V DC
- Warranty : Provided for products in normal use
Product Usage Instructions
Electrical Installation
- Switch off the mains power before installation.
- Ensure compatibility with constant voltage LED fixtures and use the appropriate driver (12V for 12V products, 24V for 24V products).
- Connect cables with correct polarity (+ to +, – to -) and do not wire output to the main supply.
- Verify that the LED driver’s power capacity exceeds the total load of connected products.
- Use suitable cables considering voltage drop, current rating, and type to prevent overheating.
Mechanical Installation
- Install the driver in a ventilated area away from explosive gases and mount it on a metal surface to dissipate heat.
- Secure the driver using fixing points and prevent mechanical damage during installation.
- Ensure cables connected to the driver are secured for strain relief.
Environmental
- The product warranty covers faults related to quality during normal use.
- Warranty exclusions include damage from unauthorized usage, disassembly, or severe physical damage.
FAQ:
- Q: What should I do if the driver generates excessive heat?
- A: Ensure proper ventilation and mounting on a metal surface, and verify that the load does not exceed the driver’s capacity.
- Q : Can I use this driver with non-LED fixtures?
- A: No, this product is designed for use with compatible constant voltage LED fixtures only.
Precautions
Installation Notes
- Install in accordance with all local wiring regulations and building regulations.
- This product must be installed and serviced by a qualified professional.
IMPORTANT
- Please read prior to installation.
- Please read these instructions carefully before commencing any work.
- Please retain these instructions for future reference.
Electrical
- Switch the power off at the mains supply before installing or maintaining this fitting.
- Ensure others cannot restore the electrical power supply without your knowledge.
- Only install compatible constant voltage LED fixtures and controls. 12V products should be used with a 12V driver and 24V products should be used with a 24V driver. Contact technical support or visit the product page for compatible products. Connect
- products with correct polarity. The positive cable (+) should be connected to the positive terminal on the driver. The negative cable (-) should be connected to the negative terminal on the driver.
- Do not wire output (SEC) to the main supply.
- Ensure that the power capacity of the LED driver is greater than the total load of all the connected products.
- Ensure appropriate cables are installed between the driver, fixtures, and any controllers. When choosing cable, factor in voltage drop, current rating and type. Inadequate cables could overheat and cause a fire.
- The maximum length of the output cable to the light source should not exceed 2 metres to meet EMC standards.
- The minimum distance between the plug top and the driver must not be less than 1.5 metres.
- Do not install if the product has visible damage.
- Do not modify or disassemble the product beyond instructions or the warranty will be void.
Mechanical
- The driver will generate heat during use. It should be installed in a well-ventilated location free from explosive gases and vapours and mounted to a surface that will dissipate this heat i.e. metal, not wood or plastic.
- The driver should be fixed to a surface using fixing points.
- Protect the driver from mechanical damage. Take care not to dislodge any components during installation. Ensure that cables connected to the driver cannot be pulled and are secured to provide strain relief.
Environmental
- The product should only be used in an environment with an ambient temperature between -20°C to +40°C. The temperature of the LED driver should never exceed 80°C when in operation.
- IP20 drivers are not waterproof and can only be installed indoors and with humidity of no more than 55%. IP67 drivers are suitable for indoor and outdoor installation.
- Install in a location without chemicals like sulphur, acid and halogen present.
- Avoid direct exposure to sunlight and protect cables from UV rays with a suitable silicone sheath.
Warranty
Product Warranty
- A warranty period is provided for products in normal use. For any faults arising during the period that are confirmed to be quality-related by inspection by the company, a product of the same specification will be replaced for free.
- The warranty does not cover any of the following:
- Any product damage due to usage is not allowed in the instructions.
- Any product damage due to disassembling or wrong operation by the user.
- Severe appearence damage or deformation of the product.
WARNING
Shock hazard. May result in serious injury or death. Isolate supply before
installation. Complete electrical safety checks before commissioning. Inspect
regularly in accordance with local regulations
WARNING
Risk of fire. Ensure correct cable sizing, over-current protection, and
ventilation and keep away from combustible materials.
Mounting Location
Wiring Diagram
Installation
Refer to the “Electrical” section listed in the precautions. Ensure all components are compatible. Configure and pre-test the system prior to permanent installation.
- Unscrew and remove the covers from the driver.
- Connect the LED system on the output (SEC) side of the driver. Check polarity.
- Connect the main supply wires on the input (PRI) side of the driver. Check polarity.
- Replace the covers and screw down ensuring cables are firmly clamped.
- Complete electrical safety checks.
List of SKU’s
SKU | Dimensions | Mounting Points (F1 x F2) |
---|---|---|
TAG12V15W / TAG24V15W | L 103mm x W 35.3mm x H 16mm | 89.8mm x 31.8mm |
TAG12V30W / TAG24V30W | L 154mm x W 50mm x H 14mm | 144.3mm x 44.95mm |
TAG12V75W-S / TAG24V75W-S | L 170mm x W 44.5mm x H 28.2mm | 160.4mm x 40.6mm |
TAG12V100W-S / TAG24V100W-S | L 170mm x W 44.5mm x H 28.2mm | 160.4mm x 40.6mm |
TAGTHIN12V45W | L 251mm x W 30mm x H 16mm | 244.7mm x 26.8mm |
TAGTHIN12V60W / TAGTHIN24V60W | L 304.6mm x W 30mm x H 16.7mm | 298.2mm x 26.8mm |
TAGTHIN12V75W | L 304.6mm x W 30mm x H 16.7mm | 298.2mm x 26.8mm |
TAG12V216W / TAG24V200W | L 195mm x W 67.1mm x H 31.2mm | 182.8mm x 60mm |
TAG24V60W | L 160mm x W 58mm x H 18mm | 148.2mm x 52.5mm |
TAGTHIN24V100W | L 320.6mm x W 30mm x H 18.2mm | 312.2mm x 26.8mm |
TAGTHIN24V200W | L 356.4mm x W 32.1mm x H 22.3mm | 347.1mm x 28.6mm |
TAG24V150W-S | L 179.4mm x W 62.5mm x H 30.6mm | 168.8mm x 58.2mm |
TAG24V320W | L 215mm x W 77.5mm x H 35mm | 201.7mm x 67.9mm |
TAGTRIAC12V30W / TAGTRIAC24V30W | L 158mm x W 45.8mm x H18.3mm | 141.8mm x |
41.2mm
TAGTRIAC12V50W / TAGTRIAC24V50W| L 177mm x W 57.8mm x H 21.8mm| 158.8mm x
53.2mm
TAGTRIAC12V100W / TAGTRIAC24V100W| L 200.8mm x W 63mm x H 30mm| 195.1mm x
20.3mm
TAGTRIAC24V75W| L 170.4mm x W 56.5mm x H 31mm| 160.1mm x 51mm
TAGTRIAC24V150W| L 195mm x W 67.1mm x H 31.2mm| 182.8mm x 62.2mm
ORION-D-200/24V| L 310mm x W 60mm x H 45mm| 300.7mm x 45.3mm
0161 442 1180 | Southfield Ind. Estate, Trafford Park, Manchester, M17 1SJ
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>