BEGA 24 649 Wall Luminaires with Directed Light Instruction Manual

June 12, 2024
BEGA

BEGA 24 649 Wall Luminaires with Directed Light

Instructions for use

BEGA-24-649-Wall-Luminaires-with-Directed-Light-FIG-1

Application

  • Cast aluminium ceiling and wall luminaire with exceptionally high luminous efficiency.
  • In combination with a reflector unit, the composite lens system delivers maximum transmission values and optimal visual comfort.
  • Product description
  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass with optical structure
  • Reflector made of pure anodised aluminium Silicone gasket 2 mounting holes ø 7 mm
  • Distance apart 310 mm 2 screw cable glands with strain relief  for through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed at the factory with a dummy plug
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • c  – Conformity mark
  • Weight: 4.8 kg

This product contains light sources of energy efficiency classes C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to  the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against  e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at: www.bega.com.

Installation

  • Unscrew the locking screw (wrench size 3) through the side opening in the luminaire housing.
  • Turn the lower part of the luminaire approx. 20° to the left and then lift it out of the upper part of the luminaire.
  • Disconnect the earth conductor connection from the plug connection.
  • Disconnect plug-connection of the LED connecting cable.
  • Lead the mains supply cable through the screw cable gland into the luminaire back housing. The installed black gasket insert is intended for cables ø < 10 mm.
  • For cables ø 10-12 mm the enclosed grey gasket insert must be used.
  • In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert.
  • Notice position of use “arrow down” of the luminaire back plate.
  • At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).BEGA-24-649-Wall-Luminaires-with-Directed-Light-FIG-2
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Tighten screw cable glands firmly.
  • Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Connect the green and yellow protective earth conductor from the luminaire top to the terminal marked 1 in the luminaire base.
  • Connect the LED connection cable by means of a plug connector.
  • Make sure that gasket is positioned correctly. Insert the luminaire top into the luminaire base so that the lateral bore holes in the rim of the housing are positioned at an offset of approx. 20° to the locking system on the luminaire base.
  • Push down on the luminaire top and turn it clockwise as far as it will go.
  • Tighten the locking screw (hexagon socket screw wrench size 3 mm) through the opening in the luminaire housing.

Lamp

  • Module connected wattage 37.7 W
  • Luminaire connected wattage 41 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

24 649 K3

  • Module designation LED-1233/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6675 lm
  • Luminaire luminous flux 5440 lm
  • Luminaire luminous efficiency 132,7 lm / W

24 649 K4

  • Module designation LED-1233/830
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 7020 lm
  • Luminaire luminous flux 5721 lm
  • Luminaire luminous efficiency 139,5 lm / W

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Glass/Trim frame graphite 25 000 155
  • Glass/Trim frame white 25 000 156
  • LED power supply unit DEV-0270/1050
  • LED module 3000 K LED-1233/830
  • LED module 4000 K LED-1233/840
  • Reflector 76 002 041
  • Gasket 83 001 123

CONTACT

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals