BEGA 99 458 Pendant Luminaire for Catenary Systems Instruction Manual

June 12, 2024
BEGA

BEGA 99 458 Pendant Luminaire for Catenary Systems

BEGA-99-458-Pendant-Luminaire-for-Catenary-Systems-PRODUCT-
IMG

Product Information

The product is a pendant luminaire designed for use with catenary systems. It has a symmetrical flat beam light distribution, making it suitable for illuminating streets according to DIN EN 13 201. The luminaire’s cable hanger system is compatible with transverse suspension systems and longitudinal chain systems.

Dark Sky: The luminaire directs its light evenly and efficiently onto the surface to be illuminated, without emitting any light into the upper half- space.

Safety: The installation and operation of this luminaire must comply with national safety regulations. Only qualified electricians should carry out the installation and commissioning. The manufacturer is not liable for any damage caused by improper use or installation. Modifications to the luminaire should only be made by authorized personnel. Overvoltage Protection: The luminaire’s electronic components are protected against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

Lamp Specifications:

  • Module Connected Wattage: 31.2 W
  • Luminaire Connected Wattage: 34.6 W
  • Rated Temperature: ta = 25°C
  • Ambient Temperature: ta max = 60°C

Module Specifications:

  • Module Designation: 4x LED-0363/840
  • Colour Temperature: 4000 K
  • Colour Rendering Index (CRI): CRI > 80
  • Module Luminous Flux: 6180 lm
  • Luminaire Luminous Flux: 5173 lm
  • Luminaire Luminous Efficiency: 149.5 lm / W

Note: The desiccant bag inside the luminaire housing should not be removed as it is necessary for removing residual moisture.

Product Usage Instructions

  1. Ensure that the installation and operation of the luminaire comply with national safety regulations.
  2. Only a qualified electrician should perform the installation and commissioning of the luminaire.
  3. Do not make any modifications to the luminaire without authorization.
  4. If additional protection against overvoltage or transients is required, use separate overvoltage protection components available on the manufacturer’s website.
  5. Keep the desiccant bag inside the luminaire housing to remove residual moisture.

DIMENSIONS

BEGA-99-458-Pendant-Luminaire-for-Catenary-Systems-
FIG-1

Instructions for use

Application

  • Pendant luminaire with symmetrical flat beam light distribution for use with catenary systems.
  • Their light distribution is especially suitable for illuminating streets according to DIN EN 13 201.
  • The cable hanger system of the luminaire is suitable for transverse suspension systems and longitudinal chain systems.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Safety glass, antireflection-coated Silicone gasket
  • Reflector made of pure anodised aluminium
  • Cable hanger for tension cable of ø 5 mm to ø 12 mm with suspending bracket and cable clamp
  • Thrust screws M8 and lock nuts are made of stainless steel – grade No 1.4301
  • Horizontal infinitely adjustable ± 5°
  • Vertical infinitely adjustable 360°
  • Connection box with cable entries for throughwiring of mains supply cable ø 10-14 mm max. 5 × 2,5@
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 66
  • Dust-tight and protection against strong water jets
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • BEGA-99-458-Pendant-Luminaire-for-Catenary-Systems-FIG-3 – Safety mark
  •  – Conformity mark
  • Wind catching area: 0.065 m²
  • Weight: 8.2 kg
  • This product contains light sources of energy efficiency class(es) C

Dark Sky
The light of this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. No light is emitted into the upper half-space of the luminaire.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.

Lamp

  • Module connected wattage 31.2 W
  • Luminaire connected wattage 34.6 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 60 °C

99 458 K4

  • Module designation 4x LED-0363/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6180 lm
  • Luminaire luminous flux 5173 lm
  • Luminaire luminous efficiency 149,5 lm / W

99 458 K3

  • Module designation 4x LED-0363/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 6020 lm
  • Luminaire luminous flux 5039 lm
  • Luminaire luminous efficiency 145,6 lm / W

Installation

  • Place cable hanger with luminaire onto the tension cable. Align unit axially.
  • Make tight connection between cable clamp with thrust screws M8 and tension cable.
  • Secure thrust screw with lock nut.
  • For through-wiring of the mains supply cable the dummy screw gland must be replaced with enclosed screw cable gland.
  • Open the connection box and lead free line ends into connection box.
  • Make earth conductor connection und electrical connection to connecting terminal.
  • For digital control please use the connecting terminal DA, DA.
  • In case this connector is not used the luminaire will be operated at full light output.
  • Tighten screw cable glands firmly.
  • When no through wiring is done, one screw cable gland must be closed with the enclosed dummy plug. Close the connection box.
  • Make sure that the gasket is positioned correctly.
  • Tighten screws evenly.
  • In case the supporting cable is not stretched in a horizontal position it is possible to bring the luminaire in a horizontal burning position by adjusting the screw joint at the junction box. Adjustable range ± 5°.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0270/700
  • LED module 3000 K LED-0363/830
  • LED module 4000 K LED-0363/840
  • Reflector 76 001 172
  • Gasket housing 83 001 401
  • Gasket connection box 83 002 009

BEGA Gantenbrink-Leuchten KG

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals