Application
Ceiling and wall luminaire with hand-blown, satin matt opal glass. For a soft and uniform light distribution.
Some of the light exits behind the shield and also illuminates the mounting surface.

Product description

Luminaire made of aluminium alloy and stainless steel BEGA Unidure®  coating technology Opal glass satin matt Silicone gasket 2 mounting holes ø 5.5 mm Distance apart 283 mm2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5   1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection BEGA Ultimate Driver ®   LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V DALI-controllable Basic insulation is provided between the mains and control cables

BEGA Thermal Control®  Temporary thermal regulation to protect temperature- sensitive components without  witching off the luminaire  Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical  impacts < 1 joule   Safety mark Conformity mark Weight: 4.4 kg This product contains light sources of energy efficiency classes C

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc.
we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp

Module connected wattage 27.6 W
Luminaire connected wattage 30.8 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

24 044 K3

Module designation LED-0832/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 4935 lm
Luminaire luminous flux 2895 lm
Luminaire luminous efficiency 94 lm / W

24 044 K4

Module designation LED-0832/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 5010 lm
Luminaire luminous flux 2939 lm
Luminaire luminous efficiency 95,4 lm / W

Installation

Lead the mains supply cable through the cable entry of the luminaire base. Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctlyPlace the opal glass with LED unit onto the luminaire base in such a way that both yellow  arrow markers align to each other and screwthe glass clockwise into the base up to the stop.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.

Disconnect the system.
Turn the opal glass with the integrated LED unit to the left as far as it will go, and remove it. Disconnect the plug-in device.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

To dismantle the LED unit, the two springs must be removed. To do this, use a small screwdriver to move the spring clip resting against the hexagon socket screw upwards and over the head of the screw (see drawing A). The spring can then be removed. Loosen the hexagon socket screws and take the LED unit out of the opal glass. Replace the LED modules. Please follow the installation instructions for the LED module.  Insert the LED unit into the opal glass and secure it in place. Then insert the springs at the two  pposite hexagon socket screws. Make sure that the spring clip is properly located behind the heads of the screws (see drawing B).BEGA 24 044 Ceiling and Wall Luminaire -
LED

Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Place the opal glass with LED unit onto the luminaire base in such a way that both yellow arrow markers align to each other and screw the glass clockwise into the base up to the stop.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.

Spares

LED power supply unit DEV-0270/700i
LED module 3000 K LED-0832/830
LED module 4000 K LED-0832/840
Glass with shield 75 004 036
Gasket 83 001 636

24 044
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com

Documents / Resources

| BEGA 24 044 Ceiling and Wall Luminaire [pdf] Instruction Manual
24 044 Ceiling and Wall Luminaire, 24 044, Ceiling and Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals