BEGA 24 044 Ceiling and Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Technical amendments reserved
24 044 Ceiling and Wall Luminaire
Ceiling and wall luminaire
Instructions for use
Application
Ceiling and wall luminaire with hand-blown, satin matt opal glass. For a soft
and uniform light distribution.
Some of the light exits behind the shield and also illuminates the mounting
surface.
Product description
Luminaire made of aluminium alloy and stainless steel BEGA Unidure® coating technology Opal glass satin matt Silicone gasket 2 mounting holes ø 5.5 mm Distance apart 283 mm2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 1.5@ Connecting terminal 2.5@ with plug connection Earth conductor connection BEGA Ultimate Driver ® LED power supply unit 220-240 V x 0/50-60 Hz DC 176-264 V DALI-controllable Basic insulation is provided between the mains and control cables
BEGA Thermal Control® Temporary thermal regulation to protect temperature- sensitive components without witching off the luminaire Safety class I Protection class IP 65 Dust-tight and protection against water jets Impact strength IK06 Protection against mechanical impacts < 1 joule Safety mark Conformity mark Weight: 4.4 kg This product contains light sources of energy efficiency classes C
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc.
we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 27.6 W |
---|---|
Luminaire connected wattage | 30.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
24 044 K3
Module designation | LED-0832/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 4935 lm |
Luminaire luminous flux | 2895 lm |
Luminaire luminous efficiency | 94 lm / W |
24 044 K4
Module designation | LED-0832/840 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 5010 lm |
Luminaire luminous flux | 2939 lm |
Luminaire luminous efficiency | 95,4 lm / W |
Installation
Lead the mains supply cable through the cable entry of the luminaire base. Fix
luminaire base with enclosed or any other suitable fixing material onto the
mounting surface.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctlyPlace the opal glass with LED
unit onto the luminaire base in such a way that both yellow arrow markers
align to each other and screwthe glass clockwise into the base up to the stop.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Turn the opal glass with the integrated LED unit to the left as far as it will
go, and remove it. Disconnect the plug-in device.
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
To dismantle the LED unit, the two springs must be removed. To do this, use a small screwdriver to move the spring clip resting against the hexagon socket screw upwards and over the head of the screw (see drawing A). The spring can then be removed. Loosen the hexagon socket screws and take the LED unit out of the opal glass. Replace the LED modules. Please follow the installation instructions for the LED module. Insert the LED unit into the opal glass and secure it in place. Then insert the springs at the two pposite hexagon socket screws. Make sure that the spring clip is properly located behind the heads of the screws (see drawing B).
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Place the opal glass with LED unit onto the luminaire base in such a way that
both yellow arrow markers align to each other and screw the glass clockwise
into the base up to the stop.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Spares
LED power supply unit | DEV-0270/700i |
---|---|
LED module 3000 K | LED-0832/830 |
LED module 4000 K | LED-0832/840 |
Glass with shield | 75 004 036 |
Gasket | 83 001 636 |
24 044
BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com
Documents / Resources
| BEGA
24 044 Ceiling and Wall
Luminaire
[pdf] Instruction Manual
24 044 Ceiling and Wall Luminaire, 24 044, Ceiling and Wall Luminaire, Wall
Luminaire, Luminaire
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>