BEGA 24 030 Ceiling and Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
24 030
Ceiling and wall luminaire
Instructions for use
Application
Unshielded ceiling and wall luminaire with high protection class.
For a variety of interior and exterior lighting applications.
Product description
Luminaire made of aluminium alloy and stainless steel
BEGA Unidure® coating technology
Colour white
Opal glass
Silicone gasket
2 mounting holes ø 5.5 mm
Distance apart 283 mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G
1.5@
Connecting terminal 2.5@ with plug connection
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
– Conformity mark
Weight: 3.6 kg
This product contains light sources of energy efficiency classes C
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate vervoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 27.6 W |
---|---|
Luminaire connected wattage | 30.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | a max = 45 °C |
24 030 K3
Module designation| LED-0832/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 4935 lm
Luminaire luminous flux| 3597 lm
Luminaire luminous efficiency| 116,8 lm / W
24 030 K4
Module designation| LED-0832/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 5010 lm
Luminaire luminous flux| 3651 lm
Luminaire luminous efficiency| 118,5 lm / W
Installation
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Push plug into coupler as far as it will go.
Make sure that gasket is positioned correctly.
Place the opal glass with LED unit onto the luminaire base in such a way that
both yellow arrow markers align to each other and screw the glass clockwise
into the base up to the stop.
Cleaning & Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass | 11 002 665 11 |
---|---|
LED power supply unit | DEV-0303/350 |
LED module 3000 K | LED-0263/830 |
LED module 4000 K | LED-0263/840 |
Gasket glass | 83 001 831 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com