BEGA 22 363 Wall Luminaire Instruction Manual

June 12, 2024
BEGA

22 363
Wall luminaireBEGA 22 363 Wall Luminaire Instructions for use

Application

Wall luminaire with shielded light source.
A luminaire of high protection class and with two-sided light output.
For a variety of lighting tasks in interior and exterior lighting applications.
The used LED technique offers durability and optimal light output with low power consumption at the same time.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Matt safety glass
Silicone gasket
Reflector made of pure anodised aluminium
2 mounting holes ø 5 mm
Distance apart 172 mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
DC 170-280 V
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK04
Protection against mechanical impacts < 0.5 joule
– Safety mark
– Conformity mark
Weight: 1.4 kg
This product contains light sources of energy efficiency classes B, C

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

Module connected wattage 7.7 W
Luminaire connected wattage 10 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C

22 363 K3
Module designation| LED-0269/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 1515 lm
Luminaire luminous flux| 732 lm
Luminaire luminous efficiency| 73,2 lm / W
22 363 K4
Module designation| LED-0269/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 1560 lm
Luminaire luminous flux| 754 lm
Luminaire luminous efficiency| 75,4 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the screws and lift off the luminaire top.
Lead the mains supply cable through the cable entry into the luminaire housing.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
Make earth conductor connection between luminaire top and luminaire base.
Make sure that gasket is positioned correctly.
Note the position of application of the luminaire top “arrow down”.
Replace the luminaire top and tighten the screws evenly.
Tighten the screws evenly.

Cleaning & Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 002 665 11
LED power supply unit DEV-0303/350
LED module 3000 K LED-0263/830
LED module 4000 K LED-0263/840
Gasket glass 83 001 831