BEGA 22 453 Ceiling-Wall-Pillar Luminaire Instruction Manual

June 12, 2024
BEGA

22 453
Ceiling · Wall · Pillar luminaire
BEGA 22 453 Ceiling-Wall-Pillar Luminaire Instructions for use

Application

Ceiling, wall and pillar luminaire with safety guard.
A luminaire made of aluminium alloy and impact resistant crystal glass with light diffusing structures.

Lamp

Module connected wattage 3.8 W
Luminaire connected wattage 4.9 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 55 °C

22 453 K3

Module designation LED-0263/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 755 lm
Luminaire luminous flux 385 lm
Luminaire luminous efficiency 78,6 lm / W

22 453 K4

Module designation LED-0263/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 780 lm
Luminaire luminous flux 398 lm
Luminaire luminous efficiency 81,2 lm / W

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Crystal glass, white inside 2 mounting holes ø 5.5 mm
Distance apart 144 mm 2 cable entries for through-wiring of mains  supply cable ø 7-10.5 mm
Connecting terminal and earth conductor terminal 2.5@
BEGA Ultimate Driver® LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-264 V
BEGA Thermal Switch
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
– Conformity mark
Weight: 3.0 kg
This product contains light sources of energy efficiency classes C®

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo screws.
Remove luminaire top with glass and gasket.
Lead the mains supply cable through the cable entry into the luminaire back housing.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
In case of installation on a foundation, please observe the following: Wet concrete can be highly alkaline and must not come into contact with the luminaire permanently.
We recommend draining the installation area and painting it with insulating paint.
Make the earth conductor connection and the electrical connection.
Insert glass with gasket and luminaire top.
Make sure that the gasket is in correct position.
Tighten screws firmly.

Cleaning & Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 002 665 11
LED power supply unit DEV-0303/350
LED module 3000 K LED-0263/830
LED module 4000 K LED-0263/840
Gasket glass 83 001 831

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com