BEGA 51196.1 LED Recessed Ceiling Downlight Instruction Manual

June 12, 2024
BEGA

Recessed ceiling downlight with
zoom optics for indoor use
Instructions for use

51196.1 LED Recessed Ceiling Downlight

BEGA 51196 1 LED Recessed Ceiling Downlight - Parts 1

Application

Recessed ceiling downlight · Indoor luminaire with focusable zoom optics.
Adjustable light distribution.
To change the light distribution, optical filters are available as accessory parts.
Changing the half beam angle between 16° and 48° by twisting the lens unit.
For surface-mounted installation in indoor suspended ceilings of 5-25 mm thickness.

Product description

Recessed ceiling luminaire downlight with zoom optics without external power supply unit Luminaire housing made of cast aluminium Installation housing is made of glass-fibre reinforced polyamide with 2  fastening springs Optical lens made of silicate glass Adjustable metal adapter ring with PMMA lens combination and integrated optical filter.
Ceiling trim ring made of metal, Colour white Recessed opening ø 130 mm Required installation depth 95 mm 1 connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
Safety class BEGA 51196 1 LED Recessed Ceiling Downlight -
Icon
** – Conformity mark
Weight:** 0.75 kg
This product contains light sources of energy efficiency class(es) F

Safety

The installation and operation of this luminairare subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp
Module connected wattage Luminaire connected wattage Rated temperature Ambient temperature

Light technique
Adjustable light distribution Half beam angle 16° – 48°

Installation

Luminaire housing must not be installed in heat-insulating material.
A separate power supply unit is required to operate the luminaire.
For connection to external LED-power supply unit – accessory 13 145 or 13 203 – the luminaire is equipped with a 2-pin connector.
Note operating instructions of the LED-power supply units.
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Take the recessed luminaire out of the packaging and dismantle the individual components.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the installation housing in the recessed opening is achieved by using two adjustable springs.
Installation into inserted ceilings :
A recessed opening of 130 mm is necessary to accept the installation housing. Recessed depth min. 95 mm.
Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening.
The fastening springs catch the ceiling panel from the back side. Minimum thickness of the ceiling panel is 5 mm. If minimum thickness of the panel is less than 5 mm it must be reinforced from the reverse  side. Maximum thickness of the ceiling panel must be no mor than 25 mm.BEGA 51196 1 LED Recessed
Ceiling Downlight - Parts 2

Push the enclosed threaded rods through the two inside openings of the installation housing and guide the clamping angle of the threaded rods downwards onto the suspended ceiling.
Clip the threaded rods into their guide grooves and screw them in by hand as far as possible.
Fix in end position with screwdriver (TX 10).
This clamp fixing prevents the installation housing from turning and dropping.
Connect to the LED power supply unit.
Route the LED power supply unit through the installation housing and place it in the suspended ceiling.
Connect the 2-pin plug connector between luminaire and external LED power supply unit.

Press together the two internal fixing sliders inside the luminaire housing.
Push the luminaire housing to the end of the installation housing and then release the fixing sliders.
Turn the luminaire housing clockwise as far as it will go.
This mechanism ensures that the luminaire housing sits securely inside the installation housing.
Installation housing and external LEDpower supply unit must not be installed in heat-insulating material.
The desired half beam angle of the luminaire can be set by turning the adjustment ring with the marked cam.
The range of the half beam angles on the trim ring includes a tolerance of ± 2.5°.

BEGA 51196 1 LED Recessed Ceiling Downlight - Parts 3 Please note : To facilitate insertion of the reflector into the luminaire housing, the lens holder (as delivered) must be flush with the threaded sleeve of the reflector.
Place the reflector on the ceiling trim ring with scale.BEGA 51196 1 LED
Recessed Ceiling Downlight - ceiling trim ring with IMPORTANT: Align the lens holder of the reflector in such a way that the embossed polycarbonate sign (>PC<) points in the direction of the connection terminal.
Guide the recesses in the lens holder of the reflector over the two inner bolts and insert the reflector.
Before fixing the trim ring, the 40° position must be turned to the notch of the installation housing.
Insert the trim ring into the edge recess of the luminaire housing and tighten clockwise.
Set the desired half beam angle of the luminaire by turning the marked adjustment ring cam.
Reinsert the adapter ring with optical filter into  the housing of the zoom downlight.
The magnetic housing recess allows the  adapter ring to lock precisely into place.
If the disc combination of the adapter ring with optical filter is defective, it must be replaced.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the
LED module.
Close the luminaire.

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.
13 145 Power supply unit on/off
13 203 Power supply unit DALI
The power supply units are only suitable for the operation of one LED luminaire.
Accessories · Optical filters
13 294 flat beam
13 296 symmetrical, diffuse
13 295 asymmetrical
For the accessories a separate instructions for use can be provided upon request.

Spares

Trim ring| 20 000 044 B1
LED module 3000 K| LED-1145/930
Lens unit| 75 004 802
Adapter ring with optical filter| 75 004 849

echnical amendments reserved
BEGA Gantenbrink-Leuchten KG

Postfach 31 60
58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals