SKS 11662 Air-X-Plorer 10.0 Floor Pump
introduction
Exchange gauge floor pumps
- Loosen the union nut on the pressure gauge cap.
- Pull up the pressure gauge cap.
- Unscrew the pressure gauge at the bottom with an Allen key (size 10).
- Insert a new pressure gauge into the pressure gauge holder.
- Screw on the pressure gauge with a maximum torque of 2 Nm.
- Push the pressure gauge cap down again and secure it with the union nut.
Exchange rubber sealing cuff floor pumps
-
Remove the two Torx screws (T25) of the hose holder. Pull the cylinder rod out of the tube with a strong jerk.
-
Remove the old cup seal. If necessary, use a tool to do this (e.g. screwdriver).
-
Place the new cup over the cylinder rod until it is positioned in the designated joint.
CAUTION: Make sure that it is on the correct side! -
Grease the rubber cup seal, re-insert the cylinder rod and screw it in.
Exchange recovery system
- Loosen the union nut on the pressure gauge cap.
- Pull up the pressure gauge cap.
- Unscrew the pressure gauge at the bottom with an Allen key (size 10).
- Turn the pressure gauge holder approximately 45° anti-clockwise until you feel resistance. Then pull out the pressure gauge holder.
- Replace the non-return valve system and follow the steps mentioned above in reverse order.
- ATTENTION: Please make sure that the non-return valve system is correctly positioned in the designated fixing. Check that the spring is fitted securely!
Exchange valve seals