nVent CADDY CSBRS1 Vertical Rod Stiffener Instruction Manual
- June 12, 2024
- nVent Caddy
Table of Contents
CSBRS1 Vertical Rod Stiffener
Instruction Manual
CSBRS1 Vertical Rod Stiffener
INSTRUCTION SHEET
nVent CADDY Quick Clip Vertical Rod Stiffener
*When using Stainless Steel Threaded Rod, Calculate the Rod Stiffener Spacing and Allowable Compression Load using the Specified Minimum Yield Strength of the Stainless Steel Material **When using Stainless Steel Threaded Rod, Calculate the Maximum Allowable Tension Load using the Specified Minimum Tensile Strength of the Stainless Steel Material
WARNING:
- nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at www.nVent.com and from your nVent customer service representative.
- nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
- All instructions must be completely followed to ensure proper and safe installation and performance.
- Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and/or death, and void your warranty.
- Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.
- All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any other purpose.
NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be
observed.
Always use appropriate safety equipment such as eye protection, hard hat, and
gloves as appropriate to the application.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO,
nVent ERIFLEX, and nVent LENTON are
owned by nVent or its global affiliates. All other trademarks are the property
of their respective owners. nVent reserves the
right to change specifications without prior notice.
INSTRUCTION SHEET
Note: The rod stiffener is intended for use with 1 5/8″ x 1 5/8″ 12-ga
strut (undamaged).
If the rod stiffener does not snap into place and firmly hold the rod, remove
the rod stiffener, place the threaded rod in the opposite corner of the strut,
and reinstall the rod stiffener.
Section 3 CSBRS1 402207
Rod Size
Imperial| Metric
3/8″| M10-1.25
1/2″| MU-1.75
5/8″| Ml 6-2.00
Step 1 – Slide the CSBRS1 onto the 1″ Sch 40 (or metric equivalent) pipe.
Step 2 – Snap the CSBRS1 over the 1″ pipe rod stiffener.
Step 3 – Insert the bolt and washer that is included into the hole that is
stamped with the size of threaded rod that the CSBRS1 is being used
with. Note: Bolt will be inserted
diagonally when 1/2″ all thread rod is used
Step 4 – Tighten the lock nut intel the two ends of the CSBRS1 are closed as
shown.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.
TECHNICAL SUPPORT:
www.nVent.com
CFS459_E
© 2011 – 2018 nVent All Rights Reserved
Read User Manual Online (PDF format)