SCOPREGA 6130650 Electric Inflator Instruction Manual
- June 11, 2024
- SCOPREGA
Table of Contents
- SCOPREGA 6130650 Electric Inflator Instruction Manual
- 1. FUNCTIONAL DESCRIPTION
- PCS – PRESSURE CONTROL SYSTEM
- 2. FOREWORD
- WARNING
- 3. PRELIMINARY WARNINGS
- 4. GENERAL SAFETY RULES
- INSTRUCTIONS
- 5. INTRODUCTION
- 6. INFLATOR DESCRIPTION
- PCS-IC MODEL (code: K6130651)
- 7. TECHNICAL SPECIFICATIONS
- 8. INFLATION: PCS
- WARNING
- 9. INFLATION: PCS-IC (INTERNAL CONTROL)
- WARNING
- 10. DEFLATION – PCS AND PCS-IC
- WARNING
- 11. TROUBLESHOOTING
- 11.1 ACCESSORY WARNING
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SCOPREGA 6130650 Electric Inflator Instruction Manual
1. FUNCTIONAL DESCRIPTION
PCS – PRESSURE CONTROL SYSTEM
- MAIN SWITCH
- INFLATION PORT
- ELECTRONIC PRESSURE SENSOR
- DEFLATION PORT
- IP65 INDUSTRIAL SHUCKO PLUG
2. FOREWORD
Dear customer,
congratulations on choosing Scoprega.
We design and manufacture products of the highest quality to meet the needs of
our customers. Scoprega offers the highest quality in service as well. Our
specialised departments provide support and instructions when needed, as
wellas comprehensive technical service.
WARNING
Read these instructions before using the inflator. Failure to follow all the
instructions listed
below may result in damage to the product and/or cause serious injury to
persons.
3. PRELIMINARY WARNINGS
- Comply with all instructions in this document.
- Keep these instructions.
- Always protect the power cable.
- Do not open the inflator. Refer all servicing to qualified service personnel authorised by Scoprega. Servicing is required when the device is damaged or not working in any way.
- Do not tamper with the product. Opening the inflator will void its warranty.
- Provide suitable ventilation.
- Avoid placing objects near the product during operation.
- Keep this product out of the reach of children.
- The operating inflator produces vibrations: therefore, we recommend you to use it on the floor, so as to avoid accidental falls.
DO NOT POWER THE INFLATOR WITH A VOLTAGE HIGHER THAN THE RATED ONE
4. GENERAL SAFETY RULES
-
ALWAYS TAKE INTO ACCOUNT THE WORKING ENVIRONMENT.
Do not expose the inflator to rain. Do not use in the presence of flammable liquids or gases. -
AVOID UNINTENTIONAL STARTING.
Do not start the inflator with the inlet in contact with dust or water. -
PAY ATTENTION. Pay attention to what you are doing. Use common sense.
-
CHECK THAT THERE ARE NO DAMAGED PARTS.
Before using the inflator, carefully check its outer sides and components. -
DO NOT OPERATE portable inflators near flammable liquids or in gaseous or explosive atmospheres. The inflator motors produce sparks that can release fumes.
-
DO NOT INHALE!
The compressed air coming from the inflator is not clean. Never inhale air from your inflator.
INSTRUCTIONS
-
WARNING! RISK OF EXPLOSION.
Inflate the inflatable unit only complying with the manufacturer’s recommendations. Exceeding the pressure rating could cause the inflator to explode, resulting in personal injury. -
NEVER LEAVE THE DEVICE UNATTENDED.
Overinflation could result in serious injury and property damage. -
WARNING! RISK OF UNSAFE OPERATION.
Do not modify or attempt to repair the unit. Do not drill into or make any modifications to the inflatoror its accessories. Any modification to the product will void its warranty. -
Never carry the inflator by the flexible hose or power cable.
5. INTRODUCTION
The PCS system is a device capable of maintaining the rated pressure inside
great inflatable items within preset values (min.90 mbar, max. 450 mbar),
regardless of ambient temperature. The unit
constantly monitors pressure variation inside the inflatable item and
regulates its operation to ensure refilling and release of pressure. In the
event of a temporary power failure, the PCS system maintains all preset values
and will restart as soon as power is restored.
6. INFLATOR DESCRIPTION
The PCS (pressure control system) is a unit capable of inflating, maintaining
a preset pressure value and deflating a large inflatable item. This means that
the unit must always be connected to the
inflatable item.
The unit protection degree is IP65 and can be operated in rainy or dusty
conditions.
The PCS is supplied with adapters to be connected to the most common inflation
valves
The inflator is equipped with a thermal overload switch that trips in case of
overheating. Normal operation will restart automatically after a 20/40-minute
pause
PCS-IC MODEL (code: K6130651)
The PCS-IC model differs from the standard model as pressure is detected by a sensor inside the inflator itself. Therefore, it does not feature the pressure sensor and the cable to be connected to the inflatable unit. This model is only intended for use with 40mm diameter hoses with suitable valves (we suggest our BRAVO 260 H.V, code: A131000N)
7. TECHNICAL SPECIFICATIONS
1. Power supply 210-240 V AC, 50 Hz or
110-130 V AC, 60 Hz
2. MAX. power 2500 W
3. Pressure range 90-450 mbar (1.3-6.5 psi)
4. MAX. flow rate 2800 l/min
5. Dimensions 700x250x h 350 mm
6. Weight 15 kg
7. Protection degree 15 kg
8. Pressure check cable length* IP65 – IEC 60529
9. Rated pressure 10 metres on request (within
range)
*not provided on PCS-IC model
8. INFLATION: PCS
WARNING
CHECK THAT THE PRESSURE CONTROL HOSE IS ALWAYS CONNECTED TO THE INFLATOR AND TO THE INFLATABLE ITEM
-
Connect the inflation hose to the PCS outlet port (point 2, figure on page 3) and to the main valve of the inflatable item
-
Connect the pressure control cable with the adapter to the item auxiliary valve
WARNINGMAKE SURE THAT THE AUXILIARY VALVE FOR PRESSURE CHECK IS SUITABLE FOR THE PCS SENSOR CONNECTOR -
Connect the sensor cable to the PCS connector (point 3, figure on page 3)
-
Connect the power plug (point 5, figure on page 3) to a suitable socket
-
Switch on the green switch on the inflator (point 1, figure on page 3). The light on the switch will light up
-
2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will automatically start to inflate to the set pressure
9. INFLATION: PCS-IC (INTERNAL CONTROL)
- Connect the inflation hose to the PCS outlet port (point 2, figure on page 3) and to the main valve of the inflatable item
- Connect the power plug to a suitable socket (point 5, figure on page 3)
- Switch on the green switch on the inflator (point 1, figure on page 3). The light on the switch will light up
- 2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will automatically start to inflate to the set pressure.
WARNING
THE INFLATION/CHECK PRESSURE CAN ONLY BE CHANGED AT A SCOPREGA SERVICE CENTRE
10. DEFLATION – PCS AND PCS-IC
- Connect the hose to the PCS deflation port (point 4, figure on page 3) and to the main valve of the inflatable item
- Connect the power plug to a suitable socket (point 5, figure on page 3).
- Switch on the green switch on the inflator. The light on the switch will light up (point 1, figure on page 3).
- 2 LEDs light up and after 4 seconds the red LED turns off; the green LED indicates that the PCS will automatically start to deflate.
WARNING
DEFLATION DOES NOT STOP AUTOMATICALLY. SWITCH OFF THE INFLATOR ONCE THE INFLATABLE UNIT IS COMPLETELY EMPTIED.
11. TROUBLESHOOTING
11.1 ACCESSORY WARNING
The recommended accessories when using the inflator are the original SCOPREGA
ones.
The use of any accessory not recommended for this inflator can be dangerous.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>