BEGA 24603 Rectangle Ceiling and Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 24603 Rectangle Ceiling and Wall Luminaire

BEGA-24603-Rectangle-Ceiling-and-Wall-Luminaire-
PRODUCT

Product Description: Lichtbausteinb Rectangle Ceiling and wall luminaire
Application: Ideal for places where a soft and uniform lighting distribution is required. Suitable for interior and exterior applications.

DIMENSION

BEGA-24603-Rectangle-Ceiling-and-Wall-Luminaire-FIG-1

Specifications

  • Lamp : LED-1249/830
  • Luminaire connected wattage: 10 W
  • Colour temperature: 3000 K
  • Colour rendering index (Ra): > 80
  • Module luminous flux: 1080 lm
  • Luminaire luminous flux: 964 lm
  • Luminaire luminous efficiency: 96.4 lm/W
  • Protection class: IP 44
  • Impact strength: IK04
  • Weight: 1.4 kg
  • Energy efficiency class: F

Product Features

  • Luminaire made of aluminium alloy, aluminium, and stainless steel
    • Distance apart: 200 mm
    • Safety class: I
  • Protected against granular foreign bodies and splash water
  • Earth conductor connection
  • Temporary thermal shutdown to protect temperature-sensitive components

Instructions for use

Application

  • Lichtbausteinb Rectangle
  • Ceiling and wall luminaire for many lighting tasks.
  • Ideal for places where a soft and uniform lighting distribution is required.
  • For interior and exterior applications.

Lamp

  • Luminaire connected wattage 10 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 30 °C

24 603 K3

  • Module designation LED-1249/830
  • Colour temperature 3000 K
  • Colour rendering index Ra > 80
  • Module luminous flux 1080 lm
  • Luminaire luminous flux 964 lm
  • Luminaire luminous efficiency 96,4 lm / W

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Opal glass satin matt 2 mounting holes ø 6 mm
  • Distance apart 200 mm 1 cable entry for mains supply cable up to ø 10,5 mm
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED-Module for mains voltage
  • 220-230 V y 50/60 Hz
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water
  • Impact strength IK04
  • Protection against mechanical impacts < 0.5 joule
    • r – Safety mark
    • c  – Conformity mark
  • Weight: 1.4 kg
  • This product contains light sources of energy efficiency class(es) F

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
  • Overvoltage protection
  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against  e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Installation

  • Lead the mains supply cable through the cable entry into the luminaire back housing.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make earth conductor connection.
  • Push silicone sleeves over the lines and make electrical connection.
  • Snap the opal glass into the lower spring clips, centralise and push into the upper spring clips.

Cleaning Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • Replacing the LED module
  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified electrician or a comparably qualified person using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • Spare glass: 11 002 058 .0
  • LED module 3000 K: LED-1249/830

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals