BEGA 77 058 In Grade Luminaire Instructions
- June 12, 2024
- BEGA
Table of Contents
**BEGA 77 058 In Grade Luminaire Instructions
**
In-ground luminaire
Instructions for use
Application
Recessed location luminaire for installation in gravel, lawns, flower beds, or
in compacted surfaces. Drive-over luminaire for vehicles with pneumatic tyres.
Please note: Luminaire must not be used for installations in road lanes,
where the fixture is exposed to a horizontal strain due to braking,
acceleration and change of direction. The minimum distance to illuminated
objects above the light distribution opening must be ü 0.5 m +. For walk-
through public areas, we recommend skid-blocking glass – see accessories.
Product description
Luminaire made of stainless steel Steel grade no. 1.4301 Safety glass, white
1,8m water-resistant connecting cable 07RN8-F 3G1@ with implemented water
stopper and 1.2m PVC cable conduit LED power supply unit 220-240 V x 0/50-60
Hz DC 170-280 V Safety class I Protection class IP 68 10 m Dust-tight and
water pressure tight Maximum submersion depth 10 m Pressure load 2,000 kg (~20
kN) Impact strength IK10 Protection against mechanical impacts < 20 joule
Maximum surface temperature 20 °C (measured according to EN 60598 of ta 15 °C)
Safety mark
Conformity mark
Weight: 4.9 kg
This product contains light sources of energy efficiency classes C, D
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547. To achieve an additional
protection against e.g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician. We recommend fuse protection via a residual current
circuit breaker to be provided by the customer. The manufacturer accepts no
liability for damage caused by improper use or installation. If subsequent
modifications are made to the luminaire, the person responsible for these
modifications shall be considered the manufacturer.
Installation
Luminaire for recessed mounting in gravel, lawns and flower beds. The recessed
depth must be arranged such that the trim ring is above ground level.
When installed in compacted surfaces make sure that the housing is firmly
fixed and that the trim ring is not directly resting on the pavement or other
surfaces (Fig. A).
For this purpose installation housing 70 688 can be practical (Fig. B).
The electrical connection must be carried out with matching protection class
and safety class with suitable connection terminals (not included in the scope
of delivery) at the luminaire power supply cable. We recommend to use a BEGA
distribution box 70 730 or 71 053. To protect the luminaire power supply cable
against mechanical damage, push the included installation pipe over the cable.
Tighten the screws in the trim ring evenly crosswise.
Torque = 5Nm.
Please note:
Do not remove the desiccant bag from the luminaire housing. It is needed to
remove residual moisture.
Cleaning · Maintenance
After installation, the luminaire should first be cleaned. Building dust, residues from contact adhesives, paint splashes and rust film must be completely removed. Never use high pressure cleaners and cleaning implements made of normal steel, steel brushes or steel wool because they cause extraneous rust to form. When using stainless steel cleaners, please read the directions carefully. Cleaning agents containing hydrochloric acid and chlorides should never be used. We recommend cleaning the luminaires regularly
Lamp
Module connected wattage 7.3 W
Luminaire connected wattage 9.2 W
Rated temperature ta=25 °C
Ambient temperature ta max=45 °C
When installed in heat-insulating
material ta max=40 °C
77 058K27
Module designation LED-0381/927
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 1245 lm
Luminaire luminous flux 593 lm
Luminaire luminous efficiency 64,5 lm/W
77 058K3
Module designation LED-0381/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1260 lm
Luminaire luminous flux 600 lm
Luminaire luminous efficiency 65,2 lm/W
77 058K4
Module designation LED-0381/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 1335 lm
Luminaire luminous flux 635 lm
Luminaire luminous efficiency 69 lm/W
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted. The module can be replaced by qualified
persons using standard tools. Disconnect the electrical installation. LED are
high-quality electronic components! Please avoid touching the light output
opening of the LED directly during relamping. Clean dirt and deposits from key
openings of screw head. Do not use a high pressure cleaner. Open the luminaire
and clean. Use only solvent-free cleaners. The luminaire housing must be
completely clean and absolutely dry. Please follow the installation
instructions for the LED module. Check all screws and threads thoroughly and
grease them. Check the gasket and replace, if necessary. A broken glass must
be replaced. Insert glass with gasket – with stepped side turned upward and
the groove structure of the gasket turned downward – into the luminaire
housing. Make sure that the glass is correctly positioned in the gasket bed.
Place trim ring onto glass step and tighten screws crosswise.
Torque = 5Nm.
Accessories
140258R Skid-blocking glass BEGA skid-blocking glass with the highest rating R 13 according to DIN 51130 can be used without restriction for all public areas. Abrasion resistance according to EN ISO 10545-7 Class 3
70 688 Installation housing Distribution box for installation in soil
70 730 Distribution box with 7 cable entries Connection terminals 5 x 4@
71 053 Distribution box with 10 cable entries Connection terminals 6 x
16@
For the accessories a separate instructions for use can be provided upon
request.
Spares
Spare glass 14 000 258
Spare glass skid blocking 14 000 258 R
LED power supply unit DEV-0141/250
LED module 2700 K LED-0381/927
LED module 3000 K LED-0381/930
LED module 4000 K LED-0381/940
Gasket 83 001 718
4/4 BEGA Gantenbrink-Leuchten KG ·
Postfach 3160 · 58689 Menden ·
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>