SCHLAGE 801 Series Local and Remote Monitoring Station Installation Guide

September 5, 2024
Schlage

SCHLAGE 801 Series Local and Remote Monitoring Station

Dimension

Specifications

Audible

  • Input Req: 10-28VDC/3-14mA
  • Rated: 70dB@ 2ft @28VDC

Hook-Up Leads:

  • (4) 24 AWG – 6″ long
  • BLK (C) – Common
  • RED (U) – Unsecured
  • RED (S) – Secure
  • RED (A) – Alarm

LED Indicators:

  • Input Req: 10-28VDC/3-14mA ea.
    • Secure – Green
    • Unsecured – Red
    • Alarm – Yellow
  • Touch Entry Leads:
    • 2 Conductor, 22 AWG., 1ft White and Black

IMPORTANT NOTE
Unit must be equipped with MBS option for LEDs to work.

Description
Provides local signal to assure users that a delayed egress system is functional (code requirement). Includes audible and visual indication of lock status and delay activation. Mounts in standard single gang electrical box.

Description of Operation

The 801 is wired to a magnetic lock delayed egress system as shown on wiring diagram (page 2).

The following is an operation sequence from normal (secure) condition – through an unauthorized egress attempt – to system reset:

Condition:

  • Door closed and secure
  • Unauthorized egress attempt
  • After 15 (or 30) second delay
  • System reset
  • Legal release

801 Status

  • Alarm Silent – Green LED on
  • Alarm Sounds – Green & Red LED on
  • Alarm Sounding – Yellow & Red LED on
  • Alarm Silent – Green LED on
  • Alarm Silent – Red LED on

M490DEP

NOTES:
Fire alarm connection:
For direct connection, fire alarm terminals connect to N.C. Dry Output Contacts (open on alarm). Conductor count to mag changes to four (4). If power supply output is controlled by fire alarm, place jumper between fire alarm terminals.

Customer Service

©Allegion 2017
Printed in U.S.A.
24480857 Rev. 08/17-c

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals